Краткое содержание страницы № 1
OFF
O N
A UT O
VENT-FREE PROPANE/LP GAS
BAY FRONT FIREPLACE
OWNER’S OPERATION AND INSTALLATION MANUAL
CF26PR
19,000 to 26,000 Btu/Hr
Remote Control Ready
Patent Pending
Fireplace Shown
With Optional
Bay Front Mantel
WARNING: Improper installation,
WARNING: If the information in this manual is not
adjustment, alteration, service,
followed exactly, a fire or explosion may result caus-
or maintenance can cause injury
ing property damage, personal injury, or loss of life.
or property damage. Refer t
Краткое содержание страницы № 2
CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE 3. If you smell gas SAFETY WARNING: Do not use a • shut off gas supply blower insert, heat exchanger in- INFORMATION • do not try to light any appliance sert, or other accessory not ap- • do not touch any electrical switch; do proved for use with this heater. not use any phone in your building WARNINGS WARNING ICON G 001 • immediately call your gas supplier from a neighbor’s phone. Follow the IMPORTANT: Read this owner’s Due to high temperatures
Краткое содержание страницы № 3
AUTO ON OFF OWNER’S MANUAL SAFETY LOCAL CODES PRODUCT Install and use fireplace with care. Follow all INFORMATION FEATURES local codes. In the absence of local codes, use Continued SAFETY PILOT the latest edition of The National Fuel Gas Code, ANS Z223.1, also known as NFPA 54*. 13. Do not use fireplace if any part has been This fireplace has a pilot with an Oxygen under water. Immediately call a quali- Depletion Sensing (ODS) safety shutoff sys- *Available from: tem. The ODS/pilot is a require
Краткое содержание страницы № 4
CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE Confined and Unconfined Space PROVIDING ADEQUATE AIR FOR VENTILATION The National Fuel Gas Code, ANS Z223.1 COMBUSTION AND defines a confined space as a space whose The following are excerpts from National VENTILATION volume is less than 50 cubic feet per 1,000 Fuel Gas Code, NFPA 54/ANS Z223.1, Sec- 3 Btu per hour (4.8 m per kw) of the aggre- tion 5.3, Air for Combustion and Ventilation. gate input rating of all appliances installed WARNING: Thi
Краткое содержание страницы № 5
OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILATION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install fireplace plus any adjoining rooms with doorless passageways or ventilation grills between the rooms. 1. Determine the volume of the space (length x width x height). Length x Width x Height = ________________
Краткое содержание страницы № 6
CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE AIR FOR COMBUSTION AND 12" VENTILATION Continued Ventilation Grills VENTILATION AIR Into Adjoining Room, Ventilation Option 2 Grills Or Ventilation Air From Inside into Adjoining Remove Room, Door into Building Option 1 Adjoining Room, This fresh air would come from an adjoining Option 3 unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one withi
Краткое содержание страницы № 7
OWNER’S MANUAL * A CSA design-certified equipment shutoff INSTALLATION CAUTION: If you install the valve with 1/8" NPT tap is an acceptable fireplace in a home garage NOTICE: This heater is intended alternative to test gauge connection. Pur- • fireplace pilot and burner must for use as supplemental heat. Use chase the optional CSA design-certified be at least 18 inches above this heater along with your pri- equipment shutoff valve from your dealer. floor. mary heating system. Do not in- See A
Краткое содержание страницы № 8
AUTO ON OFF CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE 2. An optional blower accessory is avail- INSTALLATION WARNING: Do not allow any able (see Accessories, page 28). There Continued combustible materials to overlap are two options for connecting blower the firebox front facing. BUILT-IN FIREPLACE to electrical source. INSTALLATION Option one: Have a licensed electri- IMPORTANT: Noncombustible materials cian install a properly grounded, three- Built-in installation of this fireplace inv
Краткое содержание страницы № 9
OWNER’S MANUAL REMOVING BRICK LINER OPTIONAL MANTEL INSTALLATION RETAINER INSTALLATION Continued 1. Using Phillips screw driver, remove 2 Note: Refer to instructions provided with MANTEL CLEARANCES FOR screws attaching brick liner retainers to the mantel for assembly instructions. Refer BUILT-IN INSTALLATION vertical sides. to instructions below for system installa- tion. If using blower accessory (see Acces- 2. Remove brick liner retainers and discard. NOTICE: Surface temperatures of sories, pa
Краткое содержание страницы № 10
AUTO AUTO ON O N OFF OFF CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE 3. Make sure the wire harness is firmly INSTALLING BLOWER INSTALLATION connected to the terminals on the blower ASSEMBLY - GA3450T Continued bracket assembly. 4. Place brass trim on the shoulder screws 4. Note the wire locations on back of CAUTION: Label all wires prior AUTO/OFF/ON switch. Carefully re- located on the side and top of the fireplace. to disconnection when servicing move red wire from the AUTO termi- Firmly
Краткое содержание страницы № 11
AUTO ON OFF OWNER’S MANUAL 4. A licensed electrician must follow the INSTALLATION WARNING: ELECTRICAL wiring diagram in Figure 18 to connect Continued GROUNDING INSTRUCTIONS incoming electrical supply to fan kit This appliance is equipped with a wiring harness. 9. Reconnect red wire to the AUTO switch three-prong (grounding) plug for 5. Test to make sure the blower is work- position. Reconnect blue wire to the ON your protection against shock ing properly. switch position. Reconnect green and h
Краткое содержание страницы № 12
L I P F F O L O CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE Apply pipe joint sealant lightly to male We recommend that you install a sediment INSTALLATION threads. This will prevent excess sealant trap in supply line as shown in Figure 20 . Continued from going into pipe. Excess sealant in pipe Locate sediment trap where it is within could result in clogged fireplace valves. reach for cleaning. Install in piping system CONNECTING TO GAS between fuel supply and heater. Locate sedi- SUPPLY me
Краткое содержание страницы № 13
AUTO ON OFF OWNER’S MANUAL INSTALLATION Continued CONNECTING FIREPLACE TO GAS SUPPLY Installation Items Needed • Phillips screwdriver Outer • sealant (resistant to propane/LP gas, not Casing provided) 1. Route flexible gas line (provided by installer) from equipment shutoff valve into fireplace through side or rear access holes in outer casing (see Equipment Figure 21). Shut Off Valve NOTICE: Most building codes do not permit concealed gas con- nections. A flexible gas line is provided to allow
Краткое содержание страницы № 14
CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE Test Pressures Equal To or Less Than Pressure Testing Fireplace Gas INSTALLATION 1/2 PSIG (3.5 kPa) Connections Continued 1. Close equipment shutoff valve (see 1. Open equipment shutoff valve (see Figure 23). CHECKING GAS Figure 23). 2. Pressurize supply piping system by ei- CONNECTIONS 2. Open propane/LP supply tank valve. ther using compressed air or opening 3. Make sure control knob of fireplace is propane/LP supply tank valve. WARNING: Test a
Краткое содержание страницы № 15
AUTO ON OFF OWNER’S MANUAL Burner Front Front INSTALLATION One Piece Log Set Ports Continued Mounting Clips INSTALLING LOGS Back WARNING: Failure to position Back the parts in accordance with these Remote diagrams or failure to use only Receiver Figure 26 - Installing One-Piece Log set parts specifically approved with (Top View) this heater may result in property Insulating Washers damage or personal injury. Figure 28 - Installing Remote Receiver OPTIONAL WIRELESS HAND- HELD REMOTE CONTROL CAU
Краткое содержание страницы № 16
O L I P F F O H I L CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE LIGHTING INSTALLATION OPERATING INSTRUCTIONS Continued FIREPLACE Installing 9-Volt Battery (Not NOTICE: During initial operation FOR YOUR SAFETY of new heater, burning logs will Included) in Hand-Held Remote READ BEFORE give off a paper-burning smell. Control Unit LIGHTING Open a window to vent smell. This 1. Remove battery cover on back of re- will only last a few hours. mote control unit. WARNING: If you do not fol- 2. Atta
Краткое содержание страницы № 17
N O T O H L I I L OWNER’S MANUAL Thermostat Control Operation TO TURN OFF GAS OPERATING TO APPLIANCE (Optional CGHRCT Series Only) The HEATER thermostat control setting on the remote Shutting Off Heater Continued control unit can be set to any comfort 1. Turn control knob clockwise level between HI and LO. The burner will Note: If pilot does not stay lit, con- to the OFF position. turn on and off automatically to maintain tact a qualified service person or gas 2a. Set selector switch in the OF
Краткое содержание страницы № 18
CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE BURNER FLAME PATTERN OPERATING INSPECTING Figure 39 shows a correct burner flame pat- HEATER BURNERS tern. Figure 40 shows an incorrect burner Continued Check pilot flame pattern and burner flame flame pattern. If burner flame pattern is patterns often. incorrect, CGHRCTA Series Operation • turn heater off (see To Turn Off Gas to PILOT FLAME PATTERN 2b. Press the AUTO/ON/OFF button on Appliance, page 17) the hand-held remote control (see Fig- Figu
Краткое содержание страницы № 19
OWNER’S MANUAL 4. Check the injector holder located at the CABINET CLEANING AND end of the burner tube again. Remove any Air Passageways MAINTENANCE large particles of dust, dirt, lint, or pet hair • Use a vacuum cleaner or pressurized air with a soft cloth or vacuum cleaner nozzle. to clean. 5. Blow air into the primary air holes on WARNING: Turn off heater the injector holder. Exterior and let cool before cleaning. 6. In case any large clumps of dust have • Use a soft cloth dampened with a mi
Краткое содержание страницы № 20
CF26PR VENT-FREE PROPANE/LP BAY FRONT FIREPLACE TROUBLESHOOTING CAUTION: Never use a wire, WARNING: Turn off heater needle, or similar object to clean and let cool before servicing. Only Note: For additional help, visit DESA ODS/pilot. This can damage ODS/ a qualified service person should International’s technical service web site pilot unit. service and repair heater. at www.desatech.com. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMED