Краткое содержание страницы № 1
1/3 HP PEDESTAL SUMP PUMP
Model 92274
ASSEMBLY AND OPERATING INSTRUCTIONS
®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
©
®
Copyright 2004 by Harbor Freight Tools . All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
For technic
Краткое содержание страницы № 2
PRODUCT SPECIFICATIONS Item Description Electrical Requirements 115 V / 60 Hz / 5.2 Start AMPs. 1/3 HP Motor / Single Phase / 1725 RPM. Continuous Run Thermal Overload Protection. 3-Prong Power Plug / 6 Ft. Long Power Cord. Fused Circuit: 15 AMP Capacity Required. Pump Type Centrifugal / Pit Type / Self-Priming. Maximum Lift: 17 Ft. Discharge Size: 1-1/4” Diameter x 11.5 TPI Female. Maximum Particle Size 1/8” Diameter Solids. Maximum Water Temperature 140 Degrees Fahrenheit. Minimum Water Level
Краткое содержание страницы № 3
WORK AREA 1. Keep your work area clean and well lit. Cluttered and dark work areas invite accidents. 2. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power tools create sparks which may ignite the dust or fumes. 3. Keep bystanders, children, and visitors away while operating a power tool. Distractions can cause you to lose control. ELECTRICAL SAFETY 1. Grounded tools must be plugged into an outlet properly installed and groun
Краткое содержание страницы № 4
2. Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. 3. Avoid accidental starting. Be sure the circuit supplying electrical power is off before plugging in. Plugging in a Sump Pump with the electrical circuit on invites accidents. 4. Remove adjusting keys or wrenches before turning the power tool on. A wrench or a key that is left attached
Краткое содержание страницы № 5
7. Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one tool may become hazardous when used on another tool. SERVICE 1. Tool service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury. 2. When servicing a tool, use only identical replacement parts. Follow instructions in the “Inspection, Maintenance, And Cleaning” section of this manua
Краткое содержание страницы № 6
3. Your tool must be plugged into an appropriate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like that in the following illustration. (See Figure A.) 3-PRONG PLUG 115 VOLT, GROUNDED, ELECTRICAL OUTLET FIGURE A SYMBOLOGY Double Insulated Canadian Standards Association Underwriters Laboratories, Inc. Volts Alternating Current V ~ Amperes A no No Load Revolutions xxxx/min. per Minute (RPM) FIGURE B SKU 92274 For techni
Краткое содержание страницы № 7
SPECIFIC SAFETY RULES 1. Maintain labels and nameplates on the Sump Pump. These carry important information. If unreadable or missing, contact Harbor Freight Tools for a replace- ment. 2. Use the right product for the right job. There are certain applications for which this product was designed. Do not use small equipment, tools, or attach- ments to do the work of larger industrial equipment, tools, or attachments. Do not use this product for a purpose for which it was not intended. 3.
Краткое содержание страницы № 8
6. Water transfers in cycles. Do not attempt to manipulate the automatic Switch (3) to keep the Sump Pump running continuously. It is meant to shut off intermittently. Doing so will damage the Pump. 7. Make sure the discharge pipe (not included) is secured to a solid surface to ensure the stability of the Sump Pump. 8. Make sure to position the Base Plate (24) of the Sump Pump on a flat, level surface. 9. If necessary, have a certified electrician install (within six feet of where the Sump Pu
Краткое содержание страницы № 9
ASSEMBLY AND OPERATING INSTRUCTIONS NOTE: For additional information regarding the parts listed in the following pages, refer to the Assembly Diagram on page 14. 1. If necessary, have a certified electrician install (within six feet of where the Sump Pump will be located) a 115 volt, grounded, electrical outlet that is dedicated only to the Pump. Any outlet must be above the water line. 1. WARNING! Always make sure the Sump Pump is unplugged from its electrical outlet prior to assembli
Краткое содержание страницы № 10
Do not attempt to reduce the discharge size below 1-1/4” as this will affect Pump flow and performance. A Schedule 40 PVC 1-1/4” diameter Pipe is recom- mended. (See Figure D.) 7. Connect the 1-1/4” diameter Discharge Pipe to the Impeller Case (22) of the Sump Pump. Make sure to hand tighten only. Over tightening may cause the Impeller Case to crack. NOTE: Make sure the Discharge Pipe is secured to a solid surface, with appropriate hardware (not included), to ensure the stability of the Su
Краткое содержание страницы № 11
B. Water level in pit may be too low (Switch has not yet activated). Add more water to pit. C. Power Cord may not be making contact in electrical outlet. Check connec- tion. D. Float may be obstructed. Make sure the Float is free and not rubbing against the pit wall or other obstruction. 3. Pump Motor Runs, but does not discharge water. A. Check Valve (not included) may be installed backwards or is defective. Check to make sure it is installed properly and flapper i
Краткое содержание страницы № 12
INSPECTION, MAINTENANCE, AND CLEANING 1. WARNING! Make sure the Sump Pump is unplugged from its electrical outlet before performing any inspection, maintenance, or cleaning procedures. 2. Before each use, inspect the general condition of the Sump Pump. Check for clogs throughout the system, misalignment or binding of moving parts, damaged electrical wiring, damaged or loose discharge pipes, and any other condition that may affect its safe operation. If abnormal noise or vibration occur
Краткое содержание страницы № 13
PARTS LIST Part # Description Qty. Part # Description Qty. 1 Power Cord 1 14 Rotor 1 2 Screw 2 15 Fan 1 3 Switch 1 16 Front Cover 1 4 Motor Rear Cover 1 17 Screw 5 5 Star Washer 1 18 Screw 4 6 Screw 2 19 Shaft 1 7 Capacitor 1 20 Hook 1 8 Motor Enclosure 1 21 Support 1 9 Cable Clamp 1 22 Impeller Case 1 10 Float Rod 1 23 Impeller 1 11 Float 1 24 Base Plate 1 12 Stator 1 25 Screw 5 13 Bearing 2 NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually
Краткое содержание страницы № 14
ASSEMBLY DIAGRAM NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. SKU 92274 For technical questions, please call 1-800-444-3353. PAGE 14