Краткое содержание страницы № 1
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 1
READ AND SAVE THESE INSTRUCTIONS
Emerson Fans
Designed by
OLYMPIA
Ceiling Fan Owner's Manual
Model Numbers
KF100DBK01
KF100AP01
Distressed Black with
Antique Pewter with Natural
Distressed Black/Natural
Cherry/Mahogany Blades
Cherry Blades
KF100OZ01
¨
Olde Bronze with Teak/Olde
¨
Bronze Blades
Net Weight: 30.0 Lbs.
Part No. F40BP72800004 Form No. BP7280-4
U.L. Model No.: KF100
Краткое содержание страницы № 2
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 2 ! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, secure- ly fasten a warning device, s
Краткое содержание страницы № 3
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 3 This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan 1. Open styrofoam unit containing fan. Tools Needed for Assembly Remove top half of styrofoam unit. One Phillips head screwdriver Remove parts and check to see that One wire stripper you have received the following parts: One stepladder NOTE: If you are uncertain of part Three 60-watt (max.) candelabra base bulbs description,
Краткое содержание страницы № 4
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 4 2. Remove the fan motor and housing Preset Memory Feature assembly from the protective plastic Your remote control receiver is equipped bag. Place the fan assembly into the with a preset memory feature. The receiv- upper foam pad with the top of the er will remember the light intensity and fan motor facing up. speed when the light and fan are turned off The upper foam pad serves as a hold- from the wall switch. When the wall switch er for the fan
Краткое содержание страницы № 5
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 5 2. Slide the four switch levers on the code ! WARNING switch to your choice of ON (up) or down positions. Use a ball-point pen or Turning off wall switch is not suffi- cient. To avoid possible electrical small screwdriver and slide the levers shock, be sure electricity is turned off firmly up or down. at the main fuse box before wiring. All 3. In the receiver (Figure 1), slide the four wiring must be in accordance with switch levers to the same p
Краткое содержание страницы № 6
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 6 5. Reinstall the hanger ball (Figure 5) on ! WARNING the downrod as follows. Route the It is critical that the clevis pin in the three 80” motor leads through the motor coupling is properly installed hanger ball and slide the hanger ball and the setscrews securely tight- over the downrod. Position the pin ened. Failure to verify that the pin through the two holes in the downrod and setscrews are properly installed and align the hanger ball so the
Краткое содержание страницы № 7
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 7 11. Engage the connector of the switch 10-24 x 9mm TRUSS HEAD SCREW (3) housing/light fitter assembly with the motor connector (Figure 8). The two FIBER WASHER (3) connectors are color-coded and must FAN BLADE be mated correctly (color-to-color) before they can be engaged. Make sure the connectors close properly. BLADE MOTOR FLANGE CONNECTOR SWITCH HOUSING SWITCH CONNECTOR HOUSING PLATE Figure 6 8. Turn the fan motor and housing assem- bly u
Краткое содержание страницы № 8
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 8 14. You have now completed the assem- ! WARNING bly of your new ceiling fan. You can now proceed with hanging and wiring Hanger bracket must seat firmly against outlet box. If the outlet box is your fan. recessed, remove wall board until bracket contacts box. If bracket How to Hang and/or outlet box are not securely attached, the fan could wobble or Your Ceiling Fan fall. ! WARNING The fan must be hung with at least 7' OUTLET of clearance from fl
Краткое содержание страницы № 9
N N I AC IN L AC BP7280, Olympia, KF100 7/31/06 10:57 AM Page 9 is visible at the wire connectors, except How to Wire for the ground wire. Your Ceiling Fan 2. Refer to Figure 13 and 14 and connect If you feel that you do not have enough the receiver wires to the supply wires electrical wiring knowledge or experi- and the fan motor wires as follows: ence, have your fan installed by a a. Securely connect the green grounding licensed electrician. wires from the hanger ball and the hanger brack
Краткое содержание страницы № 10
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 10 STANDARD ON-OFF WALL SWITCH OR OPTIONAL SW113 WALL CONTROL BLACK BLACK TO (HOT) BLACK 120- VOLT WHITE SUPPLY WHITE WHITE GROUND BLACK TWO-CONDUCTOR BLUE WHITE CABLE (WITH GROUND) BLACK GREEN WIRE (GROUND) BLUE FROM HANGER BALL AND WHITE HANGER BRACKET Figure 14 HANGER BALL 3. Push the wires and connectors up into ! WARNING the outlet box while inserting the receiv- er fully into the hanger bracket. Position To avoid possible fire or shock
Краткое содержание страницы № 11
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 11 NOTE: Slightly loosen the four screws Operating Your securing the lower ring brackets to the Ceiling Fan switch housing assembly. IMPORTANT 9. Securely grasp one of the lower ring Fan installation must be completed, posts and raise the lower ring up to one including the installation of the fan of the lower ring brackets. Secure the blades, before testing of the remote lower ring post to the lower ring brack- control. et using a bracket mounting
Краткое содержание страницы № 12
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 12 Maintenance Accessories IMPORTANT CARE INSTRUCTIONS 1. Downrod Extension Kits (see store or for your Ceiling Fan catalog). 2. Ceiling Fan Controls (see store or cat- Periodic cleaning of your new ceiling fan is alog). the only maintenance that is needed. When cleaning, use only a soft brush or ! WARNING lint free cloth to avoid scratching the finish. The use of any other control not Abrasive cleaning agents are not required specifically approved
Краткое содержание страницы № 13
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 13 ! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. 2. Loose power line 2. Check line power connections connections to the fan, or to fan and wire. loose wire connections in the switch housing. 3. Wall switch is of
Краткое содержание страницы № 14
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 14 Repair Parts 1 2 3 5 4 14 7 6 8 15 9 10 11 18 13 16 12 17 FAN/OFF HI FOR/REV MED 23 LIGHT LOW DIMMER 26 ® 19 22 20 21 24 25 14
Краткое содержание страницы № 15
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 15 Repair Parts Listing Part Numbers Key Model No. Model No. Model No. No. Description KF100AP01 KF100DBK01 KF100OZ01 * Hanger Pack, Consisting of: 761655-34 761655-36 761655-35 1 Bracket, Hanger Assembly (1) — — — 2 Ball, Hanger (1) — — — 3 Downrod (1) — — — * Parts Bag, Containing: 762655 762655 762655 4 Wire Connector (6) — — — 5 Stud, Threaded #8-32 x 1-1/4” (2) — — — 6 Knob, Knurled #8-32 (4) — — — 7 Lockwasher, External Tooth #8 (4) — — — 8 C
Краткое содержание страницы № 16
BP7280, Olympia, KF100 7/31/06 10:57 AM Page 16 LIMITED WARRANTY What The Warranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. You must be the original purchaser or user of the product to be covered. What The Period Of Coverage Is: As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are covered by this warr