Краткое содержание страницы № 1
®
VENTED NATURAL
GAS HEATERS
OWNER’S OPERATION AND INSTALLATION MANUAL
Models: CGR65BNA, CGR65NA, CGR50BNA, CGR50NA, CGR35NA
WARNING: Improper installation,
WARNING: If the information in this manual
is not followed exactly, a fire or explosion
adjustment, alteration, service, or
may result causing property damage, per-
maintenance can cause property
sonal injury, or loss of life.
damage, personal injury or loss of
FOR YOUR SAFETY
life. Refer to this manual for cor-
— Do not store or use gasolin
Краткое содержание страницы № 2
SECTION PAGE CONTENTS Safety Information......................................................................... 3 Product Identification .................................................................... 5 Local Codes ................................................................................... 6 Unpacking .................................................................................... 6 Product Features ............................................................................ 6
Краткое содержание страницы № 3
SAFETY WARNINGS WARNING ICON G 001 IMPORTANT: Read this owner’s manual carefully and completely be- INFORMATION fore trying to assemble, operate, or service this heater. Improper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning. DANGER WARNING ICON G 001 Carbon monoxide poisoning may lead to death! Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or n
Краткое содержание страницы № 4
SAFETY WARNINGS Continued WARNING ICON G 001 INFORMATION 6. Provide the following minimum heater clearances from combustibles (as viewed Continued from the front of heater): Front: 48 inches Back: 6 inches Top: 53 inches Right Side: 12 inches Left Side: 6 inches 7. Do not run heater • where flammable liquids or vapors are used or stored • under dusty conditions 8. Never place clothing or any flammable objects on the heater or venting system. 9. Heater and venting system surfaces are very hot du
Краткое содержание страницы № 5
Blower Switch PRODUCT Control (on models Knob equipped with IDENTIFICATION blower) Ignitor Button Burner Radiants Lower Front Access Panel Figure 1 - Vented Natural Gas Heater Draft Hood Outlet for Venting System Control Valve Blower (on models equipped with blower) Figure 2 - Vented Natural Gas Heater, Rear View 5 100792
Краткое содержание страницы № 6
Install and use heater with care. Follow all local codes. In the absence of local LOCAL CODES codes, use the latest edition of the following: • National Fuel Gas Code ANSI Z223.1, also known as NFPA 54 * • National Electrical Code ANSI/NFPA 70 * *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Protection Association, Inc. Batterymarch Park Quincy, MA 02269 1. Remove heater from carton. UNPACKING 2. Remove all protective packaging appli
Краткое содержание страницы № 7
LOCATING HEATER INSTALLING HEATER WARNING WARNING ICON G 001 Continued Maintain the minimum clearances shown in Figure 3, below. If you can, provide greater clearances. WARNING ICON G 001 WARNING Never install the heater • in a mobile home or a recreational vehicle. • where curtains, furniture, clothing, or other flam- mable objects are less than 48 inches from the front, 53 inches from the top, 12 inches from the right side and 6 inches from the left side and back of heater. • directly on carp
Краткое содержание страницы № 8
VENTING HEATER INSTALLING Note: Venting/chimney materials are not supplied with heater. HEATER Continued WARNING A qualified service person must install the venting system for this heater. If venting system is not properly installed and maintained, the vent safety shut-off system will pre- vent the heater from running. Follow all local codes. WARNING This heater has a vent safety shut-off system. This system shuts off the heater gas supply if you do not vent heater properly or the venting syst
Краткое содержание страницы № 9
VENTING HEATER (continued) INSTALLING WARNING ICON G 001 WARNING HEATER Do not vent heater in any of the following ways (see Figure 4). Continued The vertical section of vent pipe must Heater must be vented to the out- extend at least two feet above the doors. Never vent heater to another highest point of any roof within ten room or inside a building. feet. Never extend vent pipe horizontally Never extend vent pipe horizontally through a chimney or flue. You must through outside wall
Краткое содержание страницы № 10
VENTING HEATER (continued) INSTALLING Proper Size Vent HEATER To safely vent heater, the vent connector pipe must be the same diameter as the draft Continued hood outlet on the rear of the heater. Pipe that is too small can cause flue gas to spill from the heater. Fasten vent connector to the draft hood outlet with a sheet metal screw. Vent Types Prefabricated or Masonry All-Fuel Chimney - This is a masonry chimney or a residential-type prefabricated chimney. Only use prefabricated chimneys list
Краткое содержание страницы № 11
CONNECTING TO GAS SUPPLY INSTALLING HEATER WARNING Continued A qualified service person must connect heater to gas supply. Follow all local codes. WARNING Never connect heater to private (non-utility) gas wells. This gas is commonly known as well-head gas. IMPORTANT: Check gas line pressure at gas meter before connecting heater to gas line. Gas line pressure must be no greater than 14 inches of water. If gas line pressure is higher, heater regulator damage could occur. Gas Meter Figure 6 - Con
Краткое содержание страницы № 12
Installation must include a manual shutoff valve, ground joint union, plugged 1/8" INSTALLING NPT tap, and a sediment trap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 7). HEATER Continued Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves. CAUTION Use pipe joint sealant that is resistant to liquid petro- leum (LP) gas. Insta
Краткое содержание страницы № 13
CHECKING GAS CONNECTIONS INSTALLING WARNING HEATER WARNING ICON G 001 Test all gas piping and connections for leaks after install- Continued ing or servicing. Correct all leaks at once. WARNING WARNING ICON G 001 Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. Pressure Testing Gas Supply Piping System Test Pressures In Excess of 1/2 PSIG 1. Disconnect heater and its individual manual sh
Краткое содержание страницы № 14
INSTALLING RADIANTS INSTALLING HEATER WARNING WARNING ICON G 001 Continued Carefully handle the glass panel. Glass edges are rounded and buffed to prevent cuts, however, chipped or broken sections of glass can present sharp edges. These sharp edges can cut skin. 1. Remove glass guard from across opening at front of heater (see Figure 8). 2. Place radiants into combustion chamber through opening at front of heater. Front of radiant sits on front radiant support (see Figure 9, page 14). Back of
Краткое содержание страницы № 15
INSTALLING GLASS PANEL INSTALLING 1. Locate the glass panel package inside the back of the heater. HEATER Continued WARNING ICON G 001 CAUTION Before installing glass panels, inspect the edges. If you notice any chips or cracks, do not install. If the surface on either side is deeply scratched, do not install. If these conditions exist, call DESA International’s Technical Ser- vice Department at 1-800-323-5190 for replacement glass panels. CAUTION WARNING ICON G 001 Do not operate heater withou
Краткое содержание страницы № 16
6. Insert top edge of glass panel into the upper glass retaining channel (see Figure 12). INSTALLING HEATER CAUTION WARNING ICON G 001 Continued Make sure you insert top edge of glass panels into the upper glass retaining channel. Do not install glass panels with top edge of glass in front of the upper glass retaining channel. Glass panels will not automatically go into the channel. You must guide the glass panels into it. Incorrect installation will damage front of heater due to excess tempera
Краткое содержание страницы № 17
AIR FOR WARNING WARNING ICON G 001 COMBUSTION This heater must have fresh air for proper operation. If not, poor fuel combustion and improper venting of flue AND gases will result. Carbon monoxide poisoning from backed-up flue gases could occur. Read the following VENTILATION instructions to insure proper fresh air for this and other fuel-burning appliances in your home. Today’s homes are built more energy efficient than ever. New materials, increased insulation, and new construction methods he
Краткое содержание страницы № 18
In the absence of local codes, use the following excerpts from the National Fuel AIR FOR Gas Code NFPA 54/ANSI Z223.1, Air for Combustion and Ventilation. COMBUSTION DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION AND Example 1: Locating Heater in Unconfined (Open) Area VENTILATION NOTICE Continued An unconfined area has a minimum air volume of 50 cubic feet for each 1000 BTU/Hr input rating of all appliances in the area (cubic feet equals length x width x height of area). Include adjoining rooms
Краткое содержание страницы № 19
Draft Hood Spillage: This is a hazardous situation. Draft hood spillage re- AIR FOR leases poisonous carbon monoxide gas into your home. COMBUSTION WARNING ICON G 001 DANGER AND Carbon monoxide poisoning may lead to death! VENTILATION If draft hood spillage occurs, check for blocked flue connectors, vent pipes, and Continued chimneys. If you find blockage, remove. Test again for spillage. If spillage still occurs or there was no blockage, you need more fresh, outside air in the house. You must p
Краткое содержание страницы № 20
Example 2: Locating Heater in Confined (Closed) Area AIR FOR COMBUSTION NOTICE A confined area has an air volume of less than 50 cubic AND feet for each 1000 BTU/Hr input rating of all appliances VENTILATION in the area (cubic feet equals length x width x height of area). Include adjoining rooms only if there are no doors Continued between the rooms. If you install this heater in a confined area, you must provide additional fresh air. Ventilating Confined Area This fresh air would come from an