Краткое содержание страницы № 1
Install guide 8022C
Customer Support: 888-515-2585 or
401-014
Visit our website www.ritetemp-thermostats.com
F
PM
F
PM
SET TEMP
SET TEMP
HEAT
HEAT
HEAT COOL AUTO ON
HEAT COOL AUTO ON
OFF FAN
OFF FAN
Краткое содержание страницы № 2
Install guide 8022C To avoid electrical shock and to prevent damage to the furnace, air conditioner, and thermostat, disconnect the power supply before beginning work. Caution This can be done at the circuit breaker, or at the appliance. You will need #1 Phillips screwdriver (small) and Tools Drill with 3/16-in. (4.8mm) bit for this installation. 1 Location On replacement installations, mount the new thermostat in place of the old one if possible. On new Installations, follow the guideli
Краткое содержание страницы № 3
2 Remove old unit Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps. Remove cover from old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side or front. These must be loosened. Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identification. Read instructions carefully before removing any wiring from existing thermostat. Wires must be labeled before they are rem
Краткое содержание страницы № 4
4 Before you Connect Wires Please follow these guidelines for safe and secure wire connections. Strip insulation 3/8 in. (9.5mm) from wire ends. Take care not to damage the labels for each wire in handling. Connect labeled wires only to a terminal with corresponding letter. Bend the wire slightly, insert the wire under the contact plate and tighten the screw down onto the wire. Do not allow wires to touch each other or parts on thermostat. Caution Wires must be routed through the hole in th
Краткое содержание страницы № 5
When you have finished making connections. hook the top of the body onto the base, swing the body down, and snap the body onto the base. 5 Install Batteries The 8022C requires batteries to operate your furnace and retain its programming in memory. Switch MODE switch to OFF and the FAN switch to AUTO. Remove the front panel battery cover and install 2 AA alkaline batteries according to the polarity noted in the compartment. Initially, all LCD segments will go on. Press the RESET b
Краткое содержание страницы № 6
6 Check Unit cont. Note: If you have an electric furnace system and the blower does not operate after installation, remove the thermostat, turn it over, and find the electric/gas heat selector jumper on the back of the control unit. Switch it to "Elect"(see Diag below). Congratulations, you have successfully installed your unit. Please proceed to the OPERATING Guide to initialize the new thermostat. 7 Power Options 1) The 8022C can run on batteries only. (2AA Alkaline) 24VAC and MV The b
Краткое содержание страницы № 7
2 WIRE Heating STEP 1 - Connect the R (or RH) wire to (GAS MILLIVOLT or 24vac the RH terminal on the thermostat. Thermostat This connects the Heater Power to the A thermostat. jumper STEP 2 - Connect the W wire to the W wire terminal on the thermostat. C R W This connects the heater control line to the thermostat. HEAT HEAT Power FURNACE Your Heater is now connected to the thermostat. NOTE: Wires marked with the dotted line are optional. Return To Page 7 PG 11 STEP 1 - Connect the R (or
Краткое содержание страницы № 8
STEP 1 - Connect the Y wire to the 4 WIRE Y terminal on the thermostat. This Thermostat connects to the Cooler compressor. A STEP 2 - Connect the RH or R wire to the RH terminal on the thermostat. jumper wire This connects the Heater/Cooler Power. RH W Y G C STEP 3 - Connect the W wire to the W terminal on the Heat Cool Heat FAN Power Comp thermostat. This connects to the heater control line. HVAC SYSTEM STEP 4 - Connect the G wire to the G terminal on the Thermostat. This connects t
Краткое содержание страницы № 9
SINGLE STAGE STEP 1 - Connect the G wire to the G HEAT PUMP terminal on the thermostat. jumper This connects the Fan. wire Thermostat STEP 2 - Add a jumper wire A between W and Y. STEP 3 - Connect the Y wire to the jumper O or B wire Y terminal on the thermostat. This connects the Compressor. G C R O or B Y STEP 4 - Connect the O or B wire to the O or B terminal 24VAC Change Comp FAN Power Over on the thermostat. (If you have both O and B contact Single Stage HEAT PUMP Ritetemp or