Table of Contents Parts Diagram............................................................................................................................................... 1 Specifi cations ............................................................................................................................................... 2 Important Safety Information ........................................................................................................................ 2 Package Co
Краткое содержание страницы № 3
Parts Diagram 1
Краткое содержание страницы № 4
Specifications Electrical rating: • 24 VAC (18-30 VAC) • DC Power: 3.0 VDC (2 “AA” batteries included) • 1 amp maximum per terminal • 3 amp maximum total load Temperature control range: 45°F to 90°F (7°C to 32°C) Accuracy: ± 1°F (± 0.5°C) System confi gurations: 1-stage heat, 1-stage cool, heat pump, electric Timing: Anti-short Cycle: 5 minutes Backlight Operation: Battery for 5 seconds, hardwired for 10 seconds Terminations: RC, RH, W, Y, B, O, GL, GH, C Important Safety Information warning!
Краткое содержание страницы № 5
To Remove Existing Thermostat ELECTRICAL SHOCK HAZARD – Turn off power at the main service panel by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. 1. Turn off power to the heating and cooling system by removing the fuse or switching the appropriate circuit breaker off. 2. Remove cover of old thermostat. This should expose the wires. 3. Label the existing wires with the enclosed wire labels before removing wires. 4. A
Краткое содержание страницы № 6
To Install Thermostat (continued) 2. To remove cover, insert and twist a coin or screwdriver in the slots on the sides of the thermostat. 3. Put thermostat base against the wall where you plan to mount it (Be sure wires will feed through the wire opening in the base of the thermostat). 4. Mark the placement of the mounting holes. 5. Set thermostat base and cover away from working area. 6. Using a 3/16” drill bit, drill holes in the places you have marked for mounting. 7. Use a hammer to tap sup
Краткое содержание страницы № 7
HARDWIRED PRE-INSTALLED JUMPER C C T F RH H R R RC E I R P W W E M T Y Y D O A B B R S C I O T C GL GL A H T GH GH 5
Краткое содержание страницы № 8
Configuration Mode The confi guration mode is used to set the RT5 to match your heating/cooling system. The RT5 functions with Friedrich PTAC models. Ensure that the thermostat is confi gured for air conditioning with ELECTRIC HEAT ONLY. To confi gure the RT5, perform the following steps: 1. Remove the cover of the thermostat by gently pulling on one of the corners. 2. Simultaneously hold the SW5 and SW6 buttons in for 5 seconds while the RT5 is in OFF mode. 3. Press the or button to change sett
Краткое содержание страницы № 9
Confi guration Mode Settings (continued) 3. Temperature Differential (1°F to 3°F) (0.5°C to 1.5°C) – Set the number of degrees between REMOTE your “setpoint” temperature and your “turn on” temperature. SET Press the or button to set differential value. ROOM Press the SW6 button to advance to the next screen. DIFF FILTER 4. Minimum Cool Setpoint (45°F to 75°F) (7°C to 24.0°C) REMOTE Adjust to control the minimum Cool set temperature allowed. SET ROOM Press the or button to select. DIFF
Краткое содержание страницы № 10
6. Room temperature offset (+9°F to -9°F) (+4.5°C to -4.5°C) REMOTE Adjust to calibrate displayed room temperature to match actual room temperature. SET Note: When not set to 0, ROOM will display ROOM Press the or button to select. DIFF Press the SW6 button to advance to the next screen. FILTER 7. Maximum compressor cycles allowed per hour (-, 2-6) REMOTE - = as many as needed, 2-6 = maximum cycles/hour SET ROOM Press the or button to select. DIFF Press the SW6 button to advance
Краткое содержание страницы № 11
Testing the Thermostat Once the thermostat is installed, it should be thoroughly tested. caution!: Do not energize the air conditioning system when the outdoor temperature is below 50 degrees. It can result in equipment damage or personal injury. Cool Test 1. Slide Mode switch to Cool mode. 2. Adjust set temperature so it is 5 degrees below room temperature. 3. Air conditioning should come on within a few seconds. Status indicator may come on. Cool Off Heat 4. Adjust the set temperature
Краткое содержание страницы № 12
(Testing the thermostat continued from Page 9) Fan Test 1. Slide Fan switch to On position. 3. Slide Fan switch to Auto position. 2. Indoor fan turns on. 4. Indoor fan turns off. Auto On Auto On Mode of Operation The RT5 is a single-stage heat, single-stage cool thermostat. The RT5 can use 24 VAC or batteries as a power supply. The RT5 can be hardwired and have no batteries installed in the battery compartment. It can also run on battery power only. When batteries are installed an
Краткое содержание страницы № 13
Troubleshooting Symptom Remedy No display For Hardwired Installation Check for 24 VAC at thermostat; display is blank when 24 VAC is not present For Battery Installation Display is blank when batteries are drained or installed incorrectly System fan does not come on Verify wiring is correct properly Check position of gas/electric switch Thermostat turns on and off too Adjust temperature differential (see “Temperature Differential,” Step 3, Page 6) frequently Fan runs continuously Check fan On/Au