Краткое содержание страницы № 1
ETA-ECM2063
AC Power Distribution Sequencer
ETA-ECM2063
AC Power Distribution Sequencer
Raceway System
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
– 1 – ETAsys.com
Specifications are subject to change without notice.
Краткое содержание страницы № 2
ETA-ECM2063 AC Power Distribution Sequencer TABLE OF CONTENTS Important Safety Instructions ................................................................................................................. 3 Introduction ........................................................................................................................................... 5 Key Features ......................................................................................................................
Краткое содержание страницы № 3
ETA-ECM2063 AC Power Distribution Sequencer IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage “ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing)
Краткое содержание страницы № 4
ETA-ECM2063 AC Power Distribution Sequencer WARNING – WHEN THE DEVICE IS IN USE • T o prevent electric shock, do not remove the product cover as there are high voltage components inside. Refer all servicing to ETA Systems. • Should any of the following irregularities occur during use, immediately switch off the power , disconnect the power cord from the AC outlet and contact ETA Systems. Do not to attempt to continue operation with the product as this may cause fire or electric sho
Краткое содержание страницы № 5
ETA-ECM2063 AC Power Distribution Sequencer INTRODUCTION Thank you for purchasing the ETA Systems ETA-ECM2063 AC Power Distribution Sequencer Raceway System. The ETA-ECM2063 is designed to offer the installer/contractor current requirement flexibility based on the needs of the equipment that will be connected to the raceway. The ETA-ECM2063 accepts up to three separate 20A 120VAC lines, allowing for up to a total of 60A to be divided throughout the system. The ETA-ECM2063 features 6 individu
Краткое содержание страницы № 6
ETA-ECM2063 AC Power Distribution Sequencer RACEWAY AC INLET KNOCKOUTS The ETA-ECM2063 can support up to three AC conduit inlets at each end. There are three knockouts on both the top and the bottom of 1 3 the raceway. Each inlet supports a double knockout size supporting standard USA electrical fittings of ⁄2" and ⁄4". The figure below is an illustration of one end of the raceway. RACEWAY MOUNTING RAILS The ETA-ECM2063 raceway has breakaway rail mounting tabs that make it convenient to sec
Краткое содержание страницы № 7
ETA-ECM2063 AC Power Distribution Sequencer CONFIGURING THE ETA-ECM2063 The ETA-ECM2063 is designed to be activated/triggered by a sequence controller like the ETA Systems ETA-SEQ6 or the ETA-ECS6RM. The ETA-ECM2063 can be configured to accept from 1 to 3 separate hard wired 20A circuits. There are three individual load sections in the ETA-ECM2063. Each load section has two separate sequence channels, with each channel having two 20A, 120VAC outlets. In summary, the ETA-ECM2063 has a total o
Краткое содержание страницы № 8
ETA-ECM2063 AC Power Distribution Sequencer WIRING THE AC MAINS Below are four configurations for load distribution. After following the wiring diagram place the label of the Internal Wiring Configuration on the panel box. Note: All electrical wiring must be done by a certified electrician. Follow the steps below for wiring the AC mains. Accessing the Internal Wiring 1. Locate the Control Input Panel. 2. Remove the four screws. (See diagram below) 3. Remove the Contr
Краткое содержание страницы № 9
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #1 - L1, L2, L3 = 20A In this load/current wiring configuration all 3 load sections (Channels 1 – 6) are connected to a single 20A AC Mains feed. Note: All electrical wiring must be done by a certified electrician. 1. Follow the steps listed in section “Accessing the Internal Wiring” 2. Choose the most convenient AC Mains inlet on the bottom of the raceway that allows for the easiest connection to the AC
Краткое содержание страницы № 10
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #2 - L1 & L2 = 20A, L3 = 20A In this load/current wiring configuration the load sections L1 & L2 (Channels 1,2,3, & 4) are connected to a single 20A AC Mains feed and load section L3 (Channels 5 & 6) is connected to second 20A AC Mains feed. Note: All electrical wiring must be done by a certified electrician. 1. Follow the steps listed in section “Accessing the Internal Wiring” 2. Choose the most conveni
Краткое содержание страницы № 11
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #3 - L1 = 20A, L2 & L3 = 20A In this load/current wiring configuration the load section L1 (Channels 1 & 2) is connected to a single 20A AC Mains feed and load sections L2 & L3 (Channels 3, 4, 5, 6) are connected to second 20A AC Mains feed. Note: All electrical wiring must be done by a certified electrician. 1. Follow the steps listed in section “Accessing the Internal Wiring” 2. Choose the most conveni
Краткое содержание страницы № 12
ETA-ECM2063 AC Power Distribution Sequencer ETA-ECM2063 Load Wiring Option #4 - L1 = 20A, L2 = 20A, L3 = 20A In this load/current wiring configuration the load section L1 (Channels 1 & 2) is connected to a single 20A AC Mains feed, load section L2 (Channels 3 & 4) is connected to second 20A AC Mains feed and load section L3 (Channels 5 & 6) is connected to third 20A AC Main feed. Note: All electrical wiring must be done by a certified electrician. 1. Follow the steps listed in sectio
Краткое содержание страницы № 13
ETA-ECM2063 AC Power Distribution Sequencer SPECIFICATIONS Type Electrical AC Power Distribution RoHS Compliant Yes Safety Listing ETL (UL60065 Standard) Front Panel Number of Channels 6 AC Outlets 12 NEMA 5-20, Switched Connectors Qty 6, 2 Position Phoenix Euro Block Style 3.5mm Spacing Remote Trigger Hard Switch Contact Closure Indicators Incoming AC (Red), Active (Green) AC Mains Interconnect Screw T erminal Block Technical Data Voltage 120V AC, 60Hz Load 20A
Краткое содержание страницы № 14
ETA-ECM2063 AC Power Distribution Sequencer NOTES: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 14 – ETAsys.com Specifications are subject to change without notice.
Краткое содержание страницы № 15
ETA-ECM2063 AC Power Distribution Sequencer NOTES: 1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A. Telephone: 800-321-6699 • Fax: 800-996-3821 – 15 – ETAsys.com Specifications are subject to change without notice.
Краткое содержание страницы № 16
ETA-ECM2063 AC Power Distribution Sequencer LIMITED WARRANTY All products manufactured by ETA Systems are warranted to the original dealer/installer, industrial or commercial purchaser to be free from defects in material and workmanship and to be in compliance with our published specifications, if any. This warranty shall extend from the date of purchase for a period of one year. Additionally, fuses and lamps carry no warranty. ETA Systems will solely at its discretion, replace at no charge