Краткое содержание страницы № 1
Instructions – Parts List
President 10:1 Ratio
Air Spray System
306402F
FOR SPRAYING HEAVY FLUIDS FROM 55 GAL. (208
liter) DRUMS
1800 psi (126 bar) Maximum Working Pressure
180 psi (12.6 bar) Maximum Air Input Pressure
Model 225877
Includes Pump, Evenflo Control, Air Supply Hose, Spray Gun, and 100
ft (30 m) Air Atomizing and Fluid Hoses.
Model 225886
Has 25 ft (8 m) hoses,
otherwise same as 225877.
Read warnings and instructions.
See page 2 for table of contents.
Краткое содержание страницы № 2
Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Warranty . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 3
WARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. Fluid injected into the skin is a serious injury. The injury may look like just a cut, but it is a serious injury. Get immediate medical attention. Do not point the gun at anyone or at any part of the body. Do not put your hand or fingers over
Краткое содержание страницы № 4
WARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury. Ground the equipment and the object being sprayed. Refer to Grounding on page 5. If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem. Provide fresh air ventilation to avoid the
Краткое содержание страницы № 5
Installation 4. Spray gun or dispensing valve: ground through General Information connection to a properly grounded fluid hose and NOTE: Reference numbers and letters in parentheses pump. in the text refer to the callouts in the figures and the parts drawing. 5. Object being sprayed: follow your local code. NOTE: Always use Genuine Graco Parts and Acces- 6. Solvent pails used when flushing: follow your local sories, available from your Graco distributor. code. Use only metal pails, which are con
Краткое содержание страницы № 6
Installation On the main air supply line, install an air line filter (B) Typical Installation to remove harmful dirt and contaminants from your Mount the Evenflo Control (1) to the pump, using the compressed air supply. Also install a bleed-type master screws supplied with it to attach the mounting plate to air valve (A). the pump base. Remove the screw and lockwasher from the bottom of the control. Position the control over the small hole of the mounting plate and reinstall the lockwasher and s
Краткое содержание страницы № 7
Operation Pressure Relief Procedure Relax-A-Valve Automatic Position With the Evenflo control, its bypass valve, and the To set the pump Relax-A-Valve (G) in the automatic pump Relax-A-Valve properly set, fluid pressure is position, loosen the locknut (H), turn the T-handle (J) relieved from the pump and hose each time you re- clockwise as far as possible, and then back-off the lease the gun trigger. Always engage the gun trigger handle four turns and tighten the nut. See Fig. 3. safety when you
Краткое содержание страницы № 8
Operation KGJ F E 9 L 13 12 1 Fig. 4 4. Set the Relax-A-Valve (G) to automatic. Mixing by Circulation (Fig. 4) 5. Open the Evenflo ball valve (L) (handle parallel to 1. Close the Evenflo bypass valve (K) by turning the body), and the bleed-type master air valve (A). valve handle clockwise. 6. Set the atomizing air pressure to the gun at 40 psi 2. Turn both air regulator handles counterclockwise (2.8 bar) by turning the left regulator handle clock- to the free position. wise. 3. Disconnect the gu
Краткое содержание страницы № 9
Maintenance Flush with a fluid that is compatible with the fluid you WARNING are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for To reduce the risk of serious injury whenever you recommended flushing fluids and flushing frequency. are instructed to relieve pressure, always follow the Always flush the pump before fluid dries on the dis- Pressure Relief Procedure on page 7. placement rod. 1. Remove and clean the strainer in the Evenflo CAUTION b
Краткое содержание страницы № 10
Parts Model 225877 10:1 President Paint Sprayer Includes items 1, 3–15 15 Model 225886 10:1 President Paint Sprayer Includes items 1, 3, 14–19 5 6 13 14 8 12 7 1 10 11 3 9 05956
Краткое содержание страницы № 11
Parts Ref Ref No. Part No. Description Qty. No. Part No. Description Qty. 1 202844 “EVEN-FLO” CONTROL 12 214951 . HOSE, air; cpld 3/4 x 1/2 See manual 306479 for parts 1 npt (mbe) 3/4” ID; 25 ft (8m) lg 1 3 203156 STURDI-CLAMP 13 214653 . HOSE, air; cpld 3/8 npt (mbe) See manual 306305 for parts 1 1/2” ID; 100 ft (30 m) lg, static free 1 4 203458 ACCESSORY KIT 14 205628 10:1 PRESIDENT PUMP includes items 5–13 1 See manual 306726 for parts 1 5 156172 . UNION, str adapter; 3/4 npt (f) x 15 2040
Краткое содержание страницы № 12
Graco Standard Warranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only wh