Краткое содержание страницы № 1
KOBE Brand Range Hood
os
Model No. / N de modèles / Modelo No.
CH7930SQB
CH7936SQB
CH7942SQB
CH7948SQB
CH-179 SERIES – 9” HEIGHT
INSTALLATION INSTRUCTIONS
AND OPERATION MANUAL
MANUEL D'INSTALLATION
ET MODE D'EMPLOI
INSTRUCCIONES DE INSTALACIÓN
Y MANUAL DE OPERACIÓN
Краткое содержание страницы № 2
[ENGLISH] ...................................................................................................................... 1 [FRENCH] ..................................................................................................................... 34 [SPANISH] .................................................................................................................... 67
Краткое содержание страницы № 3
[ENGLISH] - READ AND SAVE THESE INSTRUCTIONS - CONTENTS IMPORTANT SAFETY INSTRUCTIONS......................................................................... 2 COMPONENTS OF PACKAGE....................................................................................... 4 INSTALLATION ............................................................................................................... 5 OPERATING INSTRUCTIONS........................................................................
Краткое содержание страницы № 4
IMPORTANT SAFETY INSTRUCTIONS - PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION - WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY, OBSERVE THE FOLLOWING: 1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction. 2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities. 3) Ducted f
Краткое содержание страницы № 5
What to Do In The Event Of a Range Top Grease Fire � SMOTHER FLAMES with a tight fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE DEPARTMENT or 911. � NEVER PICK UP A BURNING PAN – You May Get Burned. � DO NOT USE WATER, including wet dishcloths or towels – a steam blast will result. � Use an extinguisher ONLY if: a) You have a Cla
Краткое содержание страницы № 6
COMPONENTS OF PACKAGE (Must keep all material for returns or refunds) Range Hood Box Duct Cover Box (Sold Separately) {A} KOBE Range Hood – 1 {H} Adjustable Duct Cover - 1 {B} Warranty Registration Card – 1 {I} Screws Package – 1 {C} Instructions Manual – 1 {J} Duct Cover-Mounting Bracket – 1 {D} Vent Cover (Top) – 1 {K} Hood-Mounting Bracket – 1 {E} Oil Tunnel – 1 {F} Baffle Filters - 2 (30” & 36”) - 3 (42” & 48”) {H} {G} Bottom Casing – 2
Краткое содержание страницы № 7
INSTALLATION PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING Calculation before Installation To calculate installation, please refer to TABLE 1. (All calculation in inches.) - FOR UNDER THE CABINET - TABLE 1 A = Height of Floor to Ceiling B = Height of Floor to Counter Top (Standard: 36") C = Preferred Height of Counter Top to Hood Bottom (Minimum 27" to 30") D = Height of Hood E = Height of the Cabinet - FOR WALL MOUNT (WITH OPTIONAL DUCT
Краткое содержание страницы № 8
SAFETY WARNING HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF REMOVING ANY PARTS FOR INSTALLING, CLEANING OR SERVICING. NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE HOOD MAY OCCUR. Installation Contents UNDER THE CABINET Top Vent………………………………………………………………………………… 7 Rear Vent……………………………………………………………………………….. 9 WALL MOUNT Top Vent………………………………………………………………………………… 11 Rear Vent……………………………………………………………………………….. 14
Краткое содержание страницы № 9
UNDER THE CABINET INSTALLATION – TOP VENT Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1. - A straight, short venting run will allow the hood to perform more efficiently. - Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. - Temporarily wire the hood to test for pr
Краткое содержание страницы № 10
Hood Installation CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Puncture the knockout holes on the hood as shown in Figure 4. 2. If necessary, arrange the electrical wires to run through the 1” diameter hole on the top or the rear of the hood. Refer to Figure 5. 3. Using references on Table 1 and measurements on Page 22 to center the hood in place bene
Краткое содержание страницы № 11
UNDER THE CABINET INSTALLATION – REAR VENT Preparation before installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. Refer to Figure 6. - A straight, short venting run will allow the hood to perform more efficiently. - Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood. - Temporarily wire the hood to test for
Краткое содержание страницы № 12
Hood Installation CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Puncture the knockout holes on the hood as shown in Figure 10. 2. Unscrew and remove the multi duct exhaust. Replace with {D} vent cover (top). Refer to Figure 11. Figure 10
Краткое содержание страницы № 13
WALL MOUNT INSTALLATION – TOP VENT ***This installation only applied with the purchase of a duct cover. Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. Refer to Figure 13. - A straight, short venting run will allow the hood to perform more efficiently. - Try to avoid as many transitions, elbows, and long run as possible. This may reduce the perfor
Краткое содержание страницы № 14
- If necessary, attach two rubber stands (provided) with two (4x8 mm) screws (provided) to the back of the hood. - Attach the hood-mounting bracket to the back of the hood with nine (3/16" x 3/8") screws (provided) as shown in Figure 16. Hood Installation CAUTION: If required to move the cooking range to install the hood, turn off the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Using references on Table 2 and measurements on Page
Краткое содержание страницы № 15
Duct Cover Installation 3. Mark the position of the duct cover-mounting bracket. Use reference E from Table 2 and measurements on Page 22-23. Attach and secure duct cover-mounting bracket with two screws (not provided). Refer to Figure 18. NOTE: Inner duct cover will cover the duct cover-mounting bracket. 4. Use aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. 5. Connect electrical wires.
Краткое содержание страницы № 16
WALL MOUNT INSTALLATION – REAR VENT ***This installation only applied with the purchase of a duct cover. Preparation before Installation NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENING. - Decide the location of the venting pipe from the hood to the outside. Refer to Figure 21. - A straight, short venting run will allow the hood to perform more efficiently. - Try to avoid as many transitions, elbows, and long run as possible. This may reduce the perfo
Краткое содержание страницы № 17
- If necessary, attach two rubber stands (provided) with two (4x8 mm) screws (provided) to the back of the hood. - Attach the hood-mounting bracket to the back of the hood with nine (3/16" x 3/8") screws (provided) as shown in Figure 25. Hood Installation CAUTION: If required to move the cooking range to install the hood, turn OFF the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS RANGE. 1. Using references on Table 2 and measurements on Page
Краткое содержание страницы № 18
Duct Cover Installation 4. Mark the position of the duct cover-mounting bracket. Use reference E from Table 2 for references. Attach and secure duct cover-mounting bracket with two screws (not provided). Refer to Figure 27. NOTE: Inner duct cover will cover the mounting bracket. 5. Connect electrical wires. Refer to “Wiring to Power Supply” on Page 17. 6. Slide the inner duct cover up 2 inches before sliding the entire duct cover onto the hood. Refer to Figure 28.
Краткое содержание страницы № 19
Wiring to Power Supply SAFETY WARNING RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED. MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY. Connect the electrical wires. - Connect three wires (black, white and green) to house wires and cap with wire connector
Краткое содержание страницы № 20
OPERATING INSTRUCTIONS This KOBE hood is equipped with four electronic controls with a 10-second standby startup & 30-second delay shutoff, two powerful centrifugal turbine impellers with baffle filters, and bright 12-volt 20-watt halogen lights. The four electronic controls are Light Control, Speed Control A, Speed Control B and the Power Control (On/Off). Refer to Figure 32.