Краткое содержание страницы № 1
FMSS-L
Case-front self serviCe refrigerated MerChandiser
P/n igss-fMss-l-0708
INSTALLATION & OPERATION GUIDE
/CHINO
installation
& operation
Manual
FMSS-L
Case-front self serviCe rev. 0708
Краткое содержание страницы № 2
igss-fMss-l-0708 general instructions t able of Contents this Booklet Contains information on: general instructions .....................................................2 FMSS-L, FMSS-L-L-Remote Cut and Plan views ......................................................3 The FMSS-L, FMSS-L-L is a single-deck, refrigerated, installation..................................................................... 3 self-service merchandiser, which offers additional related Location .......................
Краткое содержание страницы № 3
rev. 0708 Cut and Plan views 7 3 /8" Remote 7 8 /8" S.C. 3 11 /4" 1 24" 4 /2" 5 2 /8" Ref. Drop In Elec. Drain 4' (VARIABLE LENGTHS) *Dimensions 16'' Remote adjust at theses FMSS-L 1 points to match 21 /2" S.C. Plan View service case height Scale = 1/2" FMSS-L Self-Service Remote (Self Contained) Scale = 1" ASC PARENT CASE FMSS “Field” Close Off Height Modified to match the ASC case FMSS Front-Mount Self-Service case. Can be ordered to mount in front of ANY service case. Base height can be m
Краткое содержание страницы № 4
igss-fMss-l-0708 installation (Cont'd) NOTE: A. To avoid removing concrete flooring, begin lineup 6. Slide second case up to first case snugly. Then level leveling from the highest point of the store floor. second case to the first case so glass front, bumper B. When wedges are involved in a lineup, set them first. and top are flush. All cases were leveled and joined prior to shipment to insure the closest possible fit when cases are joined in the field. When joining, use a carpenters
Краткое содержание страницы № 5
rev. 0708 installation (Cont'd) Bumper installation instructions Step : Use silicone lubricant to help the Step 1: Make sure the aluminum channel and end caps bumper slide into the channel. are installed. Step 3: Starting on one end: while inserting the bumper, Step 4: As you insert the bumper into the channel with push it up against the end cap to prevent one hand, pull the bumper toward you with the bumper from shrinking after installation the other to open the insi
Краткое содержание страницы № 6
igss-fMss-l-0708 installation (Cont'd) Boston series 2000 NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: rigid t op: do not over cut. 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base. Insert screws through the two holes of end cap and tighten. a. flexible t op: Butt end of the vinyl top against end/corner cap. While appl
Краткое содержание страницы № 7
rev. 0708 installation (Cont'd) Boston 2000 eco series 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base. Insert screws through the two holes of end cap and tighten. a. flexible t op: Butt end of the vinyl top against end/corner cap. While applying pressure, bend back vinyl top so that vinyl legs are positioned within the base grooves. Roll vinyl top over full length of base, then tap
Краткое содержание страницы № 8
igss-fMss-l-0708 installation (Cont'd) Boston 1000 series NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: rigid t op: do not over cut. installation 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base. Insert screws through the two holes of end cap and tighten. a. flexible t op: Butt end of the vinyl top against end/corner ca
Краткое содержание страницы № 9
rev. 0708 Plumbing Waste outlet and P-traP 3. Always provide as much down hill slope (“fall”) as The waste outlet is located at the left hand end of these possible; 1/8” per foot is the preferred minimum. fixtures allowing drip piping to be run under the fixture PVC pipe, when used, must be supported to lengthwise. maintain the 1/8” pitch and to prevent warping. A 1” P-TRAP and threaded adapter are supplied with each 4. Avoid long runs of condensate drains. Long runs fixture. The P-TRA
Краткое содержание страницы № 10
igss-fMss-l-0708 refrigeration (Cont'd) thermostatic expansion v alve location This device is located on the same side as the refrigeration stub. An Alco balanced port expansion valve model is furnished as standard equipment, unless otherwise specified by customer. expansion v alve adjustment Expansion valves must be adjusted to fully feed the evaporator. Before attempting any adjustments, make sure the evaporator is either clear or very lightly covered with frost, and that the fixture is
Краткое содержание страницы № 11
rev. 0708 electrical Wiring Color Code BEFORE SERVICING ALWAYS DISCONNECT ELECTRICAL POWER AT THE MAIN DISCONNECT WHEN SERVICING OR REPLACING ANY ELECTRICAL COMPONENT. This includes (but not limited to) Fans, Heaters Thermostats, and Lights. field Wiring and serial Plate amperage Field Wiring must be sized for component amperes printed on the serial plate. Actual ampere draw may be less than specified. Field wiring from the refrigeration control panel to CASE MUST BE GROUNDED the merchandise
Краткое содержание страницы № 12
igss-fMss-l-0708 User information (Cont'd) 8. Avoid the use of supplemental flood or spot lighting. Soap and hot water are not enough to kill this bacteria. A Display light intensity has been designed for sanitizing solution must be included with each cleaning maximum visibility and product life at the factory. process to eliminate this bacteria. The use of higher output fluorescent lamps (H.O. 1. Scrub thoroughly, cleaning all surfaces, with soap and V.H.O.), will shorten the shelf life o
Краткое содержание страницы № 13
rev. 0708 Maintenance FOR PROMPT SERVICE BEFORE SERVICING When contacting the factory, ALWAYS DISCONNECT ELECTRICAL be sure to have the Case Model and Serial POWER AT THE MAIN DISCONNECT Number handy. This information is on a plate WHEN SERVICING OR REPLACING ANY located on the case itself. ELECTRICAL COMPONENT. This includes (but not limited to) Fans, Heaters Thermostats, and Lights. stainless steel Cleaning and Care There are three basic things, which can break down your stainless steel’s pa
Краткое содержание страницы № 14
igss-fMss-l-0708 3. Use alkaline, alkaline Chlorinated or 5. Keep your food equipment Clean non-chloride Containing Cleaners Use alkaline, alkaline chlorinated or non-chlorinated While many traditional cleaners are loaded cleaners at recommended strength. Clean with chlorides, the industry is providing an ever frequently to avoid build-up of hard, stubborn stains. increasing choice of non-chloride cleaners. If you If you boil water in your stainless steel equipment, are not sure of your
Краткое содержание страницы № 15
rev. 0708 Wiring diagrams 8 6 4 2 1 0 CAP UNUSED RED LEAD 15 CIRCUIT #1 EVAP FAN MOTORS (1) 3 1/2" AXIAL FANS LOADING EBM-PAPST 3306 208 V 240 V 00001212A 0.12 AMPS @ 120V L1 5.7 6.6 SOLENOID VALVE L2 4.8 5.5 225-01-3206 M LOW TEMP THERMOSTAT A19AGD-21 225-01-0707 CONDUCTIVE GLASS HEATER 20 W/FT @ 120VAC (60W 0.5A) MEDIUM TEMP THERMOSTAT A19AGD-21 225-01-0707 ANTI SWEAT HEATER RELAY MARS 10 W/FT @ 120VAC (30W .25A) 90249Q 125-01-0767 225-01-2045 LIGHT TOGGLE LIGHT CIRCUIT= 0.2A 21W SWITCH DEFR
Краткое содержание страницы № 16
igss-fMss-l-0708 Wiring diagrams (Cont'd) 8 6 4 2 1 0 16 LOADING CANOPY LIGHTING 115 V 208 V 240 V (2) FP28T5/830 L1 4.37 8.83 9.33 EVAPORATOR MOTORS EBM-PAPST™ MODEL 3306 ~ 8.83 9.33 L2 M M M (3) 3½" AXIAL / 0.12A @ 115V L3 ~ ~ ~ 00001212A NOTE: CASE MUST BE GROUNDED CONDUCTIVE GLASS HEATER 0.64A @ ~115 VAC SOLEN SOLENO OIID VA D VALVE LVE 150-01-7796 ANTI-SWEAT HEATER (CASE LENGTH) RELAY MARS (2) 125-01-0767 90249Q RAYCHEM 225-01-2045 10BUT-CR-10W FMSS-L/M-8 REMOTE LOW TEMP TOTAL AM PS = 3.3 @
Краткое содержание страницы № 17
rev. 0708 Wiring diagrams (Cont'd) 8 6 4 2 1 0 17 LOADING CANOPY LIGHTING 115 V 208 V 240 V (2) FP35/T5/830 60" NOTE: THIS A SPECIAL WIRING DIAGRAM FOR 5FT & 5FT TOGETHER L1 4.8 8.5 10.0 125-03-1134 ~ 8.5 10.0 L2 EVAPORATOR MOTORS L3 ~ ~ ~ EBM-PAPST™ MODEL 3306 (4) 3½" AXIAL / 0.12A @ 115V NOTE: CASE MUST BE GROUNDED 00001212A M M M M CONDUCTIVE GLASS HEATER 0.64A @ ~115 VAC (1) 150-01-5421 (1) 150-01-5421 SOLENOID VALVE ANTI-SWEAT HEATER 225-01-3206 (CASE LENGTH) 10W/FT 125-01-0767 RELAY M
Краткое содержание страницы № 18
igss-fMss-l-0708 Wiring diagrams (Cont'd) 8 6 4 2 1 0 18 CANOPY LIGHTING (1) FP35/T5/830 LOADING 125-03-1134 NOTE: THIS A SPECIAL WIRING DIAGRAM FOR 6FT & 5FT TOGETHER 115 V 208 V 240 V L1 3.6 11.3 13.3 EVAPORATOR MOTORS ~ 11.3 13.3 L2 EBM-PAPST™ MODEL 3306 (4) 3½" AXIAL / 0.12A @ 115V L3 ~ ~ ~ 00001212A NOTE: CASE MUST BE GROUNDED CANOPY LIGHTING (2) FP21/T5/830 M M M M 125-03-1128 CONDUCTIVE GLASS HEATER 0.64A @ ~115 VAC (1) 150-01-7797 (1) 150-01-5421 ANTI-SWEAT HEATER SOLEN SOLENO OIID V
Краткое содержание страницы № 19
rev. 0708 Wiring diagrams (Cont'd) 8 6 4 2 1 0 19 LOADING 115 V 208 V 240 V NOTE: THIS A SPECIAL WIRING DIAGRAM FOR 6FT & 6FT TOGETHER L1 5.7 14.1 16.7 ~ 14.1 16.7 L2 EVAPORATOR MOTORS L3 ~ ~ ~ EBM-PAPST™ MODEL 3306 (4) 3½" AXIAL / 0.12A @ 115V NOTE: CASE MUST BE GROUNDED 00001212A M M M M CONDUCTIVE GLASS HEATER 60W @ ~115 VAC (1) 150-01-7797 (1) 150-01-7797 SOLENOID VALVE ANTI-SWEAT HEATER 225-01-3206 (CASE LENGTH) 10W/FT 125-01-0767 RELAY MARS 90249Q (2) 125-01-0767 225-01-2045 RAYCHEM 1
Краткое содержание страницы № 20
igss-fMss-l-0708 Wiring diagrams (Cont'd) 0 CIRCUIT #1 EVAP FAN MOTORS LOADING (2) 3 1/2" AXIAL FANS 208 V 240 V EBM-PAPST 3306 00001212A L1 11.4 12.9 0.12 AMPS @ 115V L2 9.6 11.1 L3 SOLENOID VALVE M M 225-01-3206 LOW TEMP THERMOSTAT A19AGD-21 225-01-0707 MEDIUM TEMP THERMOSTAT A19AGD-21 225-01-0707 5 2 CONDUCTIVE GLASS HEATER 20 W/FT @ 120VAC (80W .67A) 6 1 3 ANTI SWEAT HEATER 10 W/FT @ 120VAC (40W .33A) LIGHT 125-01-0767 RELAY MARS TOGGLE 90249Q SWITCH 225-01-2045 DEFROST HEATERS (24" FINNED