Краткое содержание страницы № 1
®
INSTALL GUIDE
2000 SERIES DRAWER MODELS
REFRIGERATORS
COMBO® REFRIGERATOR/FREEZER/ICE MAKERS
WINE CAPTAIN® MODELS
2275DWRCS 2275DWRCOL
C2275DWROL
C2275DWRS 2275DWRW
The Built-In Undercounter Leader Since 1962 U-LINE.COM
Краткое содержание страницы № 2
1 Table of Contents Safety Precautions Safety Alert Definitions.........................................................................................................................................1 General Precautions..............................................................................................................................................1 Inspect & Plan Product Registration ...................................................................................................
Краткое содержание страницы № 3
2 Safety Precautions General Precautions Use this appliance for its intended purpose only and follow these IMPO IMPOR RT TANT ANT general precautions with those listed throughout this guide: • PLEASE READ all instructions before installing, operating, or servicing the appliance. DANGER RISK OF CHILD ENTRAPMENT. Before you throw away your • Proper installation procedures must be followed when old refrigerator or freezer, take off the doors and leave shelves completing an installation or relo
Краткое содержание страницы № 4
Tools / Material Required 3 Inspect & Plan • Screwdrivers — slotted and Phillips head (If installing a 3/4” Full Overlay panel) • 3/4” overlay frame material • Cutting Tools Product Registration • Drill & Drill Bits (If installing 1/4” Panel Insert) You have received a carton containing your U-Line Combo Drawer Model Ice Maker/Refrigerator or U-Line Refrigerator with a • 1/4” thick door panel material package inside containing a Use and Care Guide, a Product • Cutting Tools Registration Card,
Краткое содержание страницы № 5
4 Prepare Site Your U-Line product has been designed for either free-standing or C2275DWR Series built-in installation. When built-in, your unit does not require additional air space for top, sides, or rear. However, the front grille must NOT be obstructed and clearance is required for an electrical connection in the rear. IMPO IMPOR RT TANT ANT • Unit can NOT be installed behind a closed cabinet door. 24" 34-1/4" WARNING to 35-1/8" 7" SHOCK HAZARD — Electrical Grounding Required. • Never r
Краткое содержание страницы № 6
C2275DWR & 2275DWRC 5 Product Dimensions 2275DWRW 2275DWRC 24" 23-15/16” 23-1/4" 23-1/4” 33-7/8” 33-7/8” 3-7/8” Black 3-7/8” Overlay 24" 23-3/8” C2275DWR 24" 23-1/4" 33-7/8" 33-7/8” 3-7/8” Stainless Steel 2275DWRW 3-7/8” Black 24" 23-15/16” 23-3/8” 23-3/8” 33-7/8" 33-7/16” 3-7/8” 3-7/8” Stainless Steel Stainless Product Dimensions 4
Краткое содержание страницы № 7
Other Site Requirements 6 Clearance Information Power Supply The unit must be installed in a wall or under a counter-top to allow The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A for the installation of the Anti-Tip Kit (see Page 14). circuit (normal household current). See Electrical Specifications. WARNING Water Supply The unit requires a 1/4-inch OD water supply line and a shut-off The Anti-Tip Kit must be installed on this unit before it valve. For more information see Page
Краткое содержание страницы № 8
IMPO IMPOR RT TANT ANT 7 Standard Drawers Drawer adjustments are made by moving the slide that carries the drawer’s rail. Minor adjustments may be made by loosening one of Checking Drawer Alignment the slide’s mounting screws, adjusting the slide and retightening the screw. Severe adjustments may be made by removing the slides’ The unit’s drawers are aligned at the factory before shipment. mounting screws, drilling new mounting holes and remounting the However, their alignment could have b
Краткое содержание страницы № 9
Minor Adjustment: Minor Adjustment: Screws Should Note: The mounting holes on the Be Loose Note: The mounting holes on the slide are slightly larger than the slide are slightly larger than the screws’ diameter. screws’ diameter. 1. Loosen one slide’s mounting Mounting Screws 1. Loosen one slide’s mounting screws. screws. 2. Push the slide upward or 2. Level the slide. downward to match the position of the other slide. 3. Retighten the screws. See Level the Slide Push Slide Figure 18. 3.
Краткое содержание страницы № 10
Full Overlay Drawer Panels 8 Drawer Panel Installation Drawer Panel Preparation Custom 1/4" Drawer Panel Inserts Full overlay drawer panels completely cover the drawer fronts and handles to give a built-in appearance. Overlay units are shipped Drawer Panel Preparation ready for Full Overlay installation. Custom drawer panels can be inserted into the drawer fronts. Note: For standard installations, both drawers mount the same and Custom drawer panels can be flat or raised, as long as the a 1
Краткое содержание страницы № 11
Attaching the Full Overlay Panel CAUTION 1. If user-supplied cabinet handles will be used, attach their It is important to ensure that all drilled holes are drilled to hardware to the overlay panel at this time. the correct depth in order to avoid splits in the wood when hardware is installed. IMPO IMPOR RT TANT ANT User-supplied cabinet handles MUST be counter bored to 4. Remove tape adjoining the panels and enlarge the five holes in make sure mounting hardware is below surface of overlay t
Краткое содержание страницы № 12
You may also mount your overlay to your grille using hook and 9 Wood Grille Overlay loop type fasteners. U-Line recommends using 3M® Dual lock® fasteners. To mount your overlay using a hook and loop fastener follow the instructions below. Grille Overlay 1. Read the instructions provided with your hook and loop Your models grille is designed to accept a wood grille over- fastener carefully. lay. An overlay may be used to compliment a door overlay and provides a seamless look for your surrou
Краткое содержание страницы № 13
Grille Drawing U-Line Grill Overlay Installation 11 Grille Overlay Dimensions 24 Inch Models 22-7/8 10-5/16 1/2 (7/16 ) 8-1/2 11/64 5/16 1/2 TYP 3X 5/16 TYP 2X 3-3/32 2-1/8 1/2 FULL R 1/4 19-5/8 23-7/8
Краткое содержание страницы № 14
10 Prepare Plumbing 10 Level The Unit Leveling Information CAUTION Note: It is recommended that the unit is level. Plumbing installation must observe all state and local 1. Use a level to check the codes. All water and drain connections MUST BE made by levelness of the unit a licensed/qualified plumbing contractor. Failure to follow from front to back and recommendations and instructions may result in damage from side to side. Level and/or harm. should be placed along top edge and side
Краткое содержание страницы № 15
2. Insert the screws through the anti-tip bracket (B) and attach the 11 Install Unit bracket to the unit. Tighten screws securely. 3. Repeat for the other side. 1. Plug in the power cord. Note: The bracket should be flush with the surface it is being 2. Open the top drawer and press the POWER icon to turn the attached to. If it is not, loosen the screws and slide the bracket OFF. unit against the mounting surface. Tighten screws securely. 3. C2275DWR Only: Open the water supply valve in the
Краткое содержание страницы № 16
First Time Start Up All U-line units are shipped from the factory with controls that are preset. No initial adjustments are required. Once installation and leveling is complete, the unit is ready for initial start-up and operation. Open the top drawer press and hold the POWER icon on the display panel for aproximately ten seconds until the °F symbol flashes and release. U-Line recommends that the unit be allowed to run overnight prior to loading the refrigerator with product. Start-Up Troub
Краткое содержание страницы № 17
® INSTALLATION GUIDE SERVICE INFORMATION If you have a problem with this appliance, your use and care guide has troubleshooting information to help you quickly identify common problems and provide information on possible cause and remedy. Answers to Customers Frequently Asked Questions are available at www.u-line.com/customer/faq.cfm. You may contact U-Line directly: GENERAL INQUIRIES: SERVICE ASSISTANCE: U-Line Corporation Phone (800) 779-2547 P.O. Box 245040 FAX (414) 354-5696 Milwaukee,