Краткое содержание страницы № 1
Operator’s Manual
Manuel d’utilisation
Manual del Operario
Questions? Help is just a moment away!
Vous avez des questions? Vous n'avez pas besoin d'aller
loin pour trouver de l'aide!
Model / Modèle / Modelo
Preguntas? La ayuda es justa un momento lejos!
Call: Helpline
074000
Appelez: Ligne d'assistance
Llame: Línea Directa
1-800-743-4115 M-F 8-5 CT
web: www.briggsandstratton.com
WARNING AVERTISSEMENT ADVERTENCIA
Before using this product, read this Avant d’utiliser ce produit, veuillez lire Ant
Краткое содержание страницы № 2
DESCRIPTION / SAFETY RULES SAVE THESE INSTRUCTIONS TABLE OF CONTENTS SAFETY RULES Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4 This is the safety alert symbol. It is used to Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 alert you to potential personal injury hazards. Obey all safety messages that follow this Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 symbol to avo
Краткое содержание страницы № 3
SAFETY RULES WARNING WARNING Hidden internal tank corrosion can cause violent Failure to read and follow instructions in manual explosion leading to severe injury and / or can result in death, bodily injury and / or property property damage. damage. Exceeding pressure rating of attachments or Before using this product, read this Operator’s Manual and inflatables can cause severe injury and / or follow all Safety Rules and Operating Instructions listed. property damage. Make this manual avail
Краткое содержание страницы № 4
SAFETY RULES WARNING WARNING Compressed air stream from hose or tank drain Compressed air is not breathable and can cause can cause soft tissue damage to exposed skin and bodily injury. can propel objects leading to severe injury Some paints or solvents may be harmful if inhaled and / or property damage. or ingested, causing severe nausea, fainting or poisoning. DO NOT direct air stream at self or others. DO NOT attempt to repair air hose(s). DO NOT use compressed air for breathing. Alwa
Краткое содержание страницы № 5
ASSEMBLY Unpacking ASSEMBLY 1. Remove accessories and packing from carton. Carton Contents 2. Lift unit out of carton. Air compressor Also Recommended for Use: Operator’s Manual Safety glasses (ANSI Z87.1 approved safety glasses with side shields) Bottle of Compressor Pump Oil Air hose - 25 ft (7.6M), 3/8 inch diameter Oil Dipstick Quick connector fitting - Use type I/M quick connect If any parts are missing, call the air compressor helpline at fittings that attach to 1/4 inch NPT
Краткое содержание страницы № 6
FEATURES AND CONTROLS FEATURES AND CONTROLS Read this Operator’s Manual and safety rules before operating your compressor. Compare this illustration with your air compressor to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference. Overload Protector Air Filter ON - OFF Switch Pressure Switch Oil Fill Location Air Compressor Pump Check Valve Quick Connect Fitting Tank Pressure Gauge Safety Valve Outlet Pressure Gauge Drain Valve Pressur
Краткое содержание страницы № 7
OPERATION 1. Make sure ON - OFF switch is in OFF position OPERATION (see Figure 2). Figure 2 - Pressure Switch with ON - OFF Switch Add Oil ON - OFF Switch 1. Place compressor on a flat, level surface. shown in OFF 2. Remove and discard the shipping cap. Using an oil funnel, position slowly fill pump with oil to notch on dipstick (See Figure 1). Figure 1 - Oil Fill Information Inset of Dipstick Oil Fill Location MAXIMUM 2. Plug power cord into grounded 120 Volt A.C. outlet (see Oil Level Groundi
Краткое содержание страницы № 8
OPERATION 3. Inspect plug and cord before each use. DO NOT use Air Compressor Operating Location compressor if there are signs of damage. Locate the air compressor in a clean, dry and well-ventilated IMPORTANT: If these grounding instructions are not area for operation.The air compressor should be placed at completely understood, or if in doubt that air compressor is least 12 inches (30 cm) away from walls or other correctly grounded, have installation checked by a qualified obstructions that co
Краткое содержание страницы № 9
OPERATION Stopping Y our Air Compressor Extension Cords 1. Push ON - OFF switch to OFF position. Compressor NOTE:Avoid use of extension cords. motor will stop. The air compressor should be located where it can be 2. If finished using compressor, unplug compressor’s power directly plugged into a grounded outlet. DO NOT use an cord from outlet. extension cord unless absolutely necessary. Instead, increase the working reach of the air hose by attaching two or more 3. Pull Safety Valve ring to relea
Краткое содержание страницы № 10
OPERATION Observe these safety precautions when operating air Compressor Operation compressor: You do not have to use the maximum operating pressure at WARNING all times because the air tool being used often requires less pressure. Here are general guidelines for setting pressure. Compressor can start any time when plugged in. 1. With air compressor connected to proper power and turned ON, attach desired air tool or accessory to quick STAY CLEAR connect fitting. Use recommended air hose and qu
Краткое содержание страницы № 11
SPECIFICATIONS / MAINTENANCE PRODUCT SPECIFICATIONS AC Frequency: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60Hz Cut-In Pressure Setting: . . . . . . . . . . . . . . . . . 80 psi (5.6 bars) Rated AC Voltage: . . . . . . . . . . . . . . . . . 120 Volts, single phase Cut/Out Pressure Setting: . . . . . . . . . . . . . . 125 PSI (8.7 bars) Running Horsepower: . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 HP Tank capacity: . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 12
MAINTENANCE Inspect Safety Valve Inspect / Change Pump Oil 1. Pull ring on Safety Valve (see Figure 7) and observe that Checking Oil Level Safety Valve operates freely. Use these steps to check oil level: Figure 7 - Safety Valve 1. Push ON - OFF switch to OFF and unplug unit. 2. Place unit on a flat, level surface. 3. Remove oil dipstick and wipe dipstick with clean cloth. 4. Reinstall dipstick into oil fill opening. 5. Carefully remove dipstick and verify that oil level is at proper level (see
Краткое содержание страницы № 13
MAINTENANCE 5. Use an adjustable wrench to remove hex head drain plug. Cooling fins on sides of Air Compressor Pump, especially between sides of pump and shroud 6. Fully drain oil into container. Install drain plug and tighten using adjustable wrench. Dispose of used oil properly. Oil fill and adjacent area on air pump housing 7. Using oil funnel, slowly add recommended oil. Check oil Oil drain on air pump housing level frequently with dipstick to avoid overfilling Pressure Control knob,
Краткое содержание страницы № 14
MAINTENANCE Inspect Pump Intake and Exhaust WARNING Valves Compressed air stream from hose or tank drain Once each year, certain internal compressor components can cause soft tissue damage to exposed skin and can propel objects leading to severe injury must be inspected. Have a trained service technician perform and / or property damage. this check, to include the air compressor pump intake and exhaust valves. DO NOT direct air stream at self or others. Always wear ANSI Z87.1 approved safet
Краткое содержание страницы № 15
STORAGE 5. Pull ring on Safety Valve and drain air from air tank to STORAGE reduce air pressure. Release Safety Valve ring. Before you store your air compressor, make sure you 6. Drain remaining air and water from tank by opening perform the following: drain valve fully counterclockwise. 1. Review MAINTENANCE beginning on page 11 and 7. Rock unit forward and back to agitate water as it drains perform scheduled maintenance as necessary. to obtain a more thorough emptying action. 2. Push ON - OFF
Краткое содержание страницы № 16
TROUBLESHOOTING TROUBLESHOOTING Before Y ou Call Figure 11 - Data Tag Information If you have any problems with the operation of your air Barcode compressor, please call the air compressor helpline at 1-800-743-4115. If calling for assistance, please have the MODEL model, revision, and serial number information printed on the Unit Information REV NO data tag available. (see Figure 11). SERIAL NO Barcode PROBLEM CAUSE CORRECTION Pressure Switch does not shut off motor Excessive tank pressure -
Краткое содержание страницы № 17
TROUBLESHOOTING PROBLEM CAUSE CORRECTION 1. Prolonged excessive use of air. 1. Decrease amount of air used. 2. Compressor is not large enough for air 2. Check the accessory requirement. If it is requirement. higher than the CFM or pressure supplied by your air compressor, you need a larger Compressor is not capacity air compressor. supplying enough air to operate accessories. 3. Hole in hose. 3. Inspect and replace if required. 4. Check Valve restricted or leaks air. 4. Contact trained service t
Краткое содержание страницы № 18
GLOSSARY GLOSSARY Becoming familiar with these terms will help you understand Cut-Out Pressure – While the compressor is running, air is and operate most air compressors: being produced and stored in the air tank. If no air is being used, air pressure will build in the tank.The Pressure Switch Air Delivery – A combination of psi and CFM.The air senses this high pressure and at a certain high level, it turns delivery required by a tool or accessory is stated as the compressor motor off.The level
Краткое содержание страницы № 19
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC AIR COMPRESSOR OWNER WARRANTY POLICY Effective October 1, 2005 replaces all undated Warranties and all Warranties dated before October 1, 2005 LIMITED WARRANTY Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the air compressor that is defective in material or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This w
Краткое содержание страницы № 20
DESCRIPTION / RÈGLES DE SÉCURITÉ VEUILLEZ CONSERVER CES INSTRUCTIONS TABLE DES MATIÈRES RÈGLES DE SÉCURITÉ Règles de sécurité . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-22 Ceci est la sûreté le symbole vif. Il est utilisé pour vous Assemblage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 alerter aux dangers de blessure personnels potentiels. Fonctions et commandes . . . . . . . . . . . . . . . . . . . . . . . . . . . .