Краткое содержание страницы № 1
SUPER AD-30
Installation/Operator's Manual
WARNING: For your safety the
AVERTISSEMENT: Assurez-vous de bien
information in this manual must be
suivre les instructions données dans cette
followed to minimize the risk of fire or notice pour réduire au minimum le risque
explosion or to prevent property damage, d’incendie ou d’explosion ou pour éviter tout
personal injury or death.
dommage matériel, toute blessure ou la mort.
Do not store or use gasoline or other flammable
Ne pas entreposer ni
Краткое содержание страницы № 2
Retain This Manual In A Safe Place For Future Reference American Dryer Corporation products embody advanced concepts in engineering, design, and safety. If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment. OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation/operator's manual included with the dryer. The following “FOR YOUR SAFETY” caution
Краткое содержание страницы № 3
IMPORTANT YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING, ADJUST- ING, INSTALLATION, or TESTING OF ANY EQUIPMENT per OSHA (Occupational Safety and Health Administration) STANDARDS. «Attention: Lor des opérations d’entretien des commandes étiqueter tous fils avant “Caution: Label all wires prior to de les déconnecter. Toute erreur de disconnection when servicing co
Краткое содержание страницы № 4
WARNING The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY or FIRE COULD RESULT. WARNING DRYER MUST NEVER BE OPERATED WITHOUT THE LINT FILTER/SCREEN IN PLACE, EVEN IF AN EXTERNAL LINT COLLECTION SYSTEM IS USED. IMPORTANT PLEASE OBSERVE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation/operator's manual included with the dryer. Dryer(s) must not be installed or stored in an area where it will b
Краткое содержание страницы № 5
Table of Contents SECTION I IMPORTANT INFORMATION ........................................................................................................ 3 A. RECEIVING and HANDLING ....................................................................................................... 3 B. SAFETY PRECAUTIONS.............................................................................................................. 4 SECTION II SUPER AD-30 SPECIFICATIONS .......................................
Краткое содержание страницы № 6
SECTION VII TROUBLESHOOTING.................................................................................................................... 44 MICROPROCESSOR (COMPUTER) MODELS ............................................................................... 44 DUAL TIMER MODELS .................................................................................................................... 50 GAS MODELS ........................................................................................
Краткое содержание страницы № 7
SECTION I IMPORTANT INFORMATION A. RECEIVING and HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery, the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage. If any damage whatsoever is noticed, inspect further before delivering carrier leaves. Dryers damaged in shipment. 1. ALL dryers should be inspected upon receipt a
Краткое содержание страницы № 8
B. SAFETY PRECAUTIONS WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. WARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed. PERSONAL INJURY or FIRE COULD RESULT. 1. DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. 2. Purchaser/user should cons
Краткое содержание страницы № 9
WARNING: DO NOT use heat for drying articles that contain plastic, foam, sponge rubber, or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and also may be a fire hazard. 7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust duct work, and inside the dryer. The frequency of inspection and cleaning can best be determined from experience at each location. WARNING: The collection of lint i
Краткое содержание страницы № 10
SECTION II SUPER AD-30 SPECIFICATIONS A. SPECIFICATIONS MAXIMUM CAPACITY (DRY WEIGHT) 30 lbs. 13.62 kg BASKET (TUMBLER) DIAMETER 30" 76.2 cm BASKET (TUMBLER) DEPTH 30" 76.2 cm 1 HP * 0.746 kw* BASKET (TUMBLER) MOTOR 3/4 HP* 0.560 kw** DOOR OPENING (DIAMETER) 21-1/2" 54.61 cm BASKET (TU MBLER) VOLUME 12.27 cu.ft. 0.347 cu.m. APPROX. WEIGHT (UNCRATED) 475 lbs. 215.65 kg. APPROX. WEIGHT (CRATED) 525 lbs. 238.35 kg DRYERS PER 20'/40' TRUCK 12/28 DRYERS PER 45'/48' TRUCK 30/32 VOLTAGE AVAILABLE 120
Краткое содержание страницы № 11
SUPER AD-30 Specifications NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation. 7
Краткое содержание страницы № 12
SECTION III INSTALLATION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable AMERICAN NATIONAL STANDARDS: ANSI.Z223.1-LATEST EDITION (National Fuel Gas Code) and/or ANSI/NFPA NO. 70-LATEST EDITION (National Electric Code) or in CANADA, the installation must conform to applicable CANADIAN STANDARDS: CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Ga
Краткое содержание страницы № 13
B. LOCATION REQUIREMENTS Before installing the dryer, be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1- LATEST EDITION, or in CANADA, the Canadian Installation Codes CAN/CGA-B149.1-M91 (Natural Gas) or CAN/CGA-B149.2-M91 (L.P. Gas) or LATEST EDITION. 1. The dryer must be installed on a sound level floor capable of supporting its weight. It is recommended that carpeting
Краткое содержание страницы № 14
C. DRYER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 12- inches (18-inches or more is recommended for ease of installation, maintenance, and service) above the dryer outer top, except along the front of the dryer which may be partially closed in if desired. The clearance between the bulkhead header and the dryer must be a minimum of 4-inches and must not extend more than 4-inches to the rear of the front. The bulk
Краткое содержание страницы № 15
D. FRESH AIR SUPPLY The SUPER AD-30 air supply (make-up air) must be given careful consideration to assure proper performance of each dryer. An unrestricted source of air is necessary for each dryer. As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet is required for each dryer. If registers or louvers are installed over the openings, then the area must be increased. It is not necessary to have a separate make-up air openings for
Краткое содержание страницы № 16
E. EXHAUST REQUIREMENTS Exhaust duct work should be designed and installed by a qualified professional. Improperly sized duct work will create excessive back pressure which results in slow drying, increased use of energy, and shutdown of the burner by the airflow (sail) switch, burner hi-limit, or lint chamber hi-heat protector thermostat. CAUTION: IMPROPERLY SIZED OR INSTALLED EXHAUST DUCT WORK CAN CREATE A POTENTIAL FIRE HAZARD. CAUTION: DRYER MUST BE EXHAUSTED TO THE OUTDOORS. The exhaust
Краткое содержание страницы № 17
SINGLE DRYER VENTING IMPORTANT: For exhaust runs over 10 feet a minimum duct size of 10-inches must be used. HORIZONTAL VENTING When single 10-inch venting is used, the duct work from the dryer to the outside outlet cannot exceed 30 feet (refer to Illus. A below). This calculation of 30 feet compensates or allows for the use of a maximum of only one (1) elbow. Illus. A 13
Краткое содержание страницы № 18
VERTICAL VENTING When vertical single venting is used minimum duct size is 12-inches (refer to Illus. B below), the duct work from the dryer to the outside outlet cannot exceed 60 feet (refer to Illus. B below). This calculation compensates for the use of a maximum of three (3) elbows including the two (2) elbows creating the 180° (turned downward) outside outlet. Illus. B If the length of the duct run or quantity of elbows used exceeds the above noted specifications, the cross section area of
Краткое содержание страницы № 19
MULTIPLE DRYER (Common) VENTING HORIZONTAL VENTING If it is not feasible to provide separate exhaust ducts for each dryer, ducts for individual dryers may be channeled into a common main duct. Each dryer is provided with a back draft damper. The individual ducts should enter the bottom or side of the main duct at an angle not more than 45° in the direction of the airflow. No more than four (4) dryers should be connected to one (1) main common duct run. The main common duct may be any shape s
Краткое содержание страницы № 20
Illus. C (refer to the previous page {page 15}) shows the minimum cross-section area for horizontal multiple dryer venting. These figures must be increased in proportion if the main duct run from the last dryer to where it exhausts has numerous elbows or is unusually long. IMPORTANT: For extended duct work runs, the cross-section area of the duct can only be increased to an extent. For extended duct work runs, a professional HVAC firm should be consulted for proper venting information. VERTICA