Краткое содержание страницы № 1
Installation
Drying Tumblers
50 Pound Capacity
75 Pound Capacity
Through Serial No. 0903xxxxx
Refer to Page 5 for Model Identification
NOTA: Para bajar una
copia de estas
instrucciones en
español, visite
www.comlaundry.com.
TMB795C
TMB795C
Keep These Instructions for Future Reference.
(If this machine changes ownership, this manual must accompany machine.)
Part No. M414905R12
March 2009
www.comlaundry.com
Краткое содержание страницы № 2
Краткое содержание страницы № 3
Installation must conform with local codes or, in the absence of local codes, with: In the U.S.A., installation must conform to the latest edition of the American National Standard Z223.1/ NFPA 54 “National Fuel Gas Code” and Standard ANSI/NFPA 70 “National Electric Code.” In Canada, installation must comply with Standards CAN/CSA-B149.1 or Natural Gas and Propane Installation Code and CSA C22.1, latest edition, Canadian Electric Code, Part I. In Australia, installation must comply with the Aus
Краткое содержание страницы № 4
WARNING • Installation of unit must be performed by a qualified installer. • Install tumbler according to manufacturer’s instructions and local codes. • DO NOT install a tumbler with flexible plastic venting materials. If flexible metal (foil type) duct is installed, it must be of a specific type identified by the appliance manufacturer as suitable for use with tumbler. Refer to section on connecting exhaust system. Flexible venting materials are known to collapse, be easily crushed, and trap
Краткое содержание страницы № 5
Introduction......................................................................................... 5 Table of Model Identification ............................................................................. 5 Customer Service.................................................................................. 7 Contents Wiring Diagram.................................................................................... 7 Serial Plate Location.....................................................
Краткое содержание страницы № 6
Steam Requirements........................................................................... 48 Piping Recommendations ..................................................................... 49 Installing Steam Trap and Making Condensate Return Connections ............................................................................ 49 Thermal Oil Prep .................................................................................. 49 Single Drop Timer ..........................................
Краткое содержание страницы № 7
Introduction Model Identification Information in this manual is applicable to these models: Gas Steam/Thermal Oil Electric AT050L HT050N AT050S UT050T AT050E AT050N HU050L CHD50S2-CT050S UU050S CHD50E2-CT050E CHD50G2-CA050L HU050N CHD50S2-CU050S UU050T CHD50E2-CU050E CHD50G2-CA050N IPD50G2-IT050L CT050T YT050S DR55E2-BT050E CHD50G2-CT050L IPD50G2-IT050N CU050T YT050T DR55E2-BU050E CHD50G2-CT050N NT050L DR55S2-BT050S GT050E CHD50G2-CU050L NT050N DR55S2-BT050T GU050E CHD50G2-CU050N SA050L DR55S2-B
Краткое содержание страницы № 8
Introduction Includes models with the following control suffixes: 3O –DX4 OPL DO –DMP OPL RD –reversing DMP OPL 3V –DX4 vended DV –DMP vended RM –reversing OPL micro 3X –DX4 prep for coin DX –DMP prep for coin RQ –reversing dual digital timer BC –basic electronic, coin MT –manual timer RT –reversing manual timer BL –basic electronic, central pay NC –NetMaster coin SD –single drop BU –basic electronic, prep card-open NR –NetMaster card SX –single drop, prep for coin BX –basic electronic, prep for
Краткое содержание страницы № 9
Introduction Customer Service Wiring Diagram If literature or replacement parts are required, contact The wiring diagram is located in the junction or the source from which the machine was purchased or contactor box. contact Alliance Laundry Systems at (920) 748-3950 Models starting Serial No. 0309_____ or later will for the name and address of the nearest authorized have the wiring diagram part number in the lower parts distributor. portion of the electrical data on the serial plate. For t
Краткое содержание страницы № 10
Safety Information Precautionary statements (“DANGER,” “WARNING,” NOTE: The word “NOTE” is used to communicate and “CAUTION”), followed by specific instructions, installation, operation, maintenance or servicing are found in this manual and on machine decals. These information that is important but not hazard precautions are intended for the personal safety of the related. operator, user, servicer, and those maintaining the machine. WARNING DANGER Failure to install, maintain, and/or operate
Краткое содержание страницы № 11
Safety Information Save These Instructions 14. The interior of the tumbler and the exhaust duct Important Safety Instructions should be cleaned periodically by qualified service personnel. WARNING 15. If not installed, operated and maintained in accordance with the manufacturer’s instructions Hazardous Voltage. Can cause shock, burn or if there is damage to or mishandling of this or cause death. Allow machine power to product’s components, use of this product could remain off for two min
Краткое содержание страницы № 12
Safety Information 23. Remove laundry immediately after tumbler 29. DO NOT bypass any safety devices. stops. 30. Solvent vapors from dry-cleaning machines 24. Always read and follow manufacturer’s create acids when drawn through the heater of the instructions on packages of laundry and cleaning drying unit. These acids are corrosive to the aids. Heed all warnings or precautions. To reduce tumbler as well as to the laundry load being the risk of poisoning or chemical burns, keep dried. Be sur
Краткое содержание страницы № 13
Specifications and Dimensions Specifications 50 Pound 75 Pound F75 63 dBA 69 dBA 67 dBA Noise level measured during operation at operator position of 3.3 feet (1 meter) in front of machine and 5.2 feet (1.6 meters) from floor. 545 615 710 Net Weight (approximate): Pounds (kg) (247) (279) (322) 37 x 30 37 x 36 37 x 36 Cylinder Size: Inches (mm) (940 x 762) (940 x 914) (940 x 914) 50 75 75 Cylinder Capacity (dry weight): Pounds (kg) (22.7) (34) (34) 8 8 10 Air Outlet Diameter: Inches (mm) (20
Краткое содержание страницы № 14
Specifications and Dimensions Cabinet Dimensions C E B D A G F TMB2210N AB Models CD E F G **** ** 50 30.75 in. 28.75 in. 28.25 in. 33.87 in. 47 in. 76.625 in. 38.625 in. 33 in. 29.5 in. Pound Gas and (781 mm) (730 mm) (717 mm) (860 mm) (1194 mm) (1946 mm) (981 mm) (838 mm) (749 mm) Electric 50 30.75 in. 28.75 in. 28.25 in. 33.87 in. 47 in. 80 in. 38.625 in. 33 in. 29.5 in. Pound (781 mm) (730 mm) (717 mm) (860 mm) (1194 mm) (2032 mm) (981 mm) (838 mm) (749 mm) Steam 75 30.75 in. 28.75 in. 28
Краткое содержание страницы № 15
Specifications and Dimensions Exhaust Outlet Locations B C A TMB811N Models ABC 5.375 in. 8 in. 13.375 in. 50/75 Pound (137 mm) (203 mm) (340 mm) 6.5 in. 10 in. 6.5 in. F75 (165 mm) (254 mm) (165 mm) M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 13
Краткое содержание страницы № 16
Specifications and Dimensions Gas Connection Locations A B TMB812N TMB812N Models Diameter A B 1/2 in. NPT 15.5 in. 65.75 in. 50 Pound (394 mm) (1670 mm) 1/2 in. NPT 15.75 in. 65.75 in. 75 Pound (400 mm) (1670 mm) 3/4 in. NPT 15.75 in. 65.75 in. F75 (400 mm) (1670 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT M414905 14
Краткое содержание страницы № 17
Specifications and Dimensions Electrical Connection Locations A A B B TMB813N GAS AND STEAM ELECTRIC TMB813N Models A B 9.5 in. 63.5 in. Gas and Steam (241 mm) (1613 mm) 19 in. 64 in. Electric (483 mm) (1626 mm) NOTE: These figures are approximate dimensions only. M414905 © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT 15
Краткое содержание страницы № 18
Specifications and Dimensions Steam Connection Locations A C B D TMB814N TMB814N Models Diameter ABCD 3/4 in. NPT 15.25 in. 72.75 in. 7.5 in. 64.75 in. 50/75 Pound (387 mm) (1848 mm) (190 mm) (1645 mm) © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT M414905 16
Краткое содержание страницы № 19
Installation Pre-Installation Inspection Materials Required (Obtain Locally) Upon delivery, visually inspect the crate, carton and One Single Pole fused disconnect parts for any visible shipping damage. If the crate, switch or circuit breaker on 1 Phase All Models carton, or cover is damaged or signs of possible models. damage are evident, have the carrier note the condition Circuit breaker on 3 Phase models. on the shipping papers before the shipping receipt is One gas shut-off valve for
Краткое содержание страницы № 20
Installation A typical tumbler enclosure is shown in Figure 1. Note Location Requirements the minimum and maximum dimensions. Local codes The tumbler must be installed on a level floor. Floor and ordinances must be complied with. covering materials such as carpeting or tile should be removed. WARNING To assure compliance, consult local building code requirements. The tumbler must not be installed or To reduce the risk of serious injury, install stored in area where it will be exposed to w