Краткое содержание страницы № 1
IM10031-A
TM
November, 2010
LN-25 PRO
For use with machines having Code Number: 11620, 11621, 11716, 11717
Safety Depends on You
Lincoln arc welding and cutting
equipment is designed and built
with safety in mind. However, your
overall safety can be increased by
proper installation ... and thoughtful
operation on your part. DO NOT
INSTALL, OPERATE OR REPAIR
THIS EQUIPMENT WITHOUT
READING THIS MANUAL AND
THE SAFETY PRECAUTIONS
CONTAINED THROUGHOUT.
And, most importantly, think before
you act a
Краткое содержание страницы № 2
i i SAFETY WARNING CALIFORNIA PROPOSITION 65 WARNINGS Diesel engine exhaust and some of its constituents The engine exhaust from this product contains are known to the State of California to cause can- chemicals known to the State of California to cause cer, birth defects, and other reproductive harm. cancer, birth defects, or other reproductive harm. The Above For Diesel Engines The Above For Gasoline Engines ARC WELDING CAN bE HAzARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIbLE SERIOUS INJURY
Краткое содержание страницы № 3
ii ii SAFETY ARC RAYS can burn. ELECTRIC SHOCK can 4.a. Use a shield with the proper filter and cover kill. plates to protect your eyes from sparks and 3.a. The electrode and work (or ground) circuits the rays of the arc when welding or observing are electrically “hot” when the welder is on. open arc welding. Headshield and filter lens Do not touch these “hot” parts with your bare should conform to ANSI Z87. I standards. skin or wet clothing. Wear dry, hole-free gloves to insulate hands. 4.b. Us
Краткое содержание страницы № 4
iii iii SAFETY WELDING and CUTTING CYLINDER may explode SPARKS can if damaged. cause fire or explosion. 7.a. Use only compressed gas cylinders 6.a. Remove fire hazards from the welding area. containing the correct shielding gas for the If this is not possible, cover them to prevent process used and properly operating the welding sparks from starting a fire. regulators designed for the gas and Remember that welding sparks and hot pressure used. All hoses, fittings, etc. should be suitable for mat
Краткое содержание страницы № 5
iv iv SAFETY PRÉCAUTIONS DE SÛRETÉ 6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles. Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce 7. Quand on ne soude pas, poser la pince à une endroit isolé de manuel aussi bien que les précautions de sûreté générales suiv- la masse. Un court-circuit accidental peut provoquer un antes: échauffement et un risqu
Краткое содержание страницы № 6
v v SAFETY Electromagnetic Compatibility (EMC) Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 15 Dec 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility, 2004/108/EC. It was manufactured in conformity with a national standard that implements a harmonized standard: EN 60974-10 Electromagnetic Compatibility (EMC) Product Standard for Arc Welding Equipment. It is for use with other Lincoln E
Краткое содержание страницы № 7
vi vi SAFETY Electromagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises. Methods of Reducing Emissions Mains Supply Welding equipment should be connected to the mains supply according to the manufacturer’s recommenda- tions. If interference occurs, it may be necessary to take additional precautions such as filter
Краткое содержание страницы № 8
vii vii for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product Thank You ••• as much pride as we have in bringing this product to you! CUSTOMER ASSISTANCE POLICY The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment, consumables, and cutting equip- ment. Our challenge is to meet the needs of our customers and to exceed their expectations. On occasion, purchasers may ask L
Краткое содержание страницы № 9
viii viii TAbLE OF CONTENTS Page –––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––– Installation.......................................................................................................................Section A Technical Specifications.......................................................................................................A-1 Safety Precautions ..............................................................................................
Краткое содержание страницы № 10
A-1 A-1 INSTALLATION TECHNICAL SPECIFICATIONS – LN-25™ PRO (K2613-1, K2613-2) INPUT VOLTAGE and CURRENT INPUT VOLTAGE ± 10% INPUT AMPERES 15-110 VDC 4A RATED OUTPUT @ 104°F (40°C) DUTY CYCLE INPUT AMPERES 60% rating 450 100% rating 325 GEARING - WIRE FEED SPEED RANGE-WIRE SIzE GMAW FCAW GEARING WIRE SIzES WIRE SIzES WFS RANGE WFS RANGE Extra torque .023 – 1/16" .030 - 3/32” 30 – 400 ipm 30 – 400 ipm K2613-2 (0.6 – 1.6mm) (10.3 – 2.4mm) (0.8 – 10.1m/min) (0.8 – 10.1m/min) Standard Speed .
Краткое содержание страницы № 11
A-2 A-2 INSTALLATION SAFETY PRECAUTIONS The handle of the LN-25™ PRO is intended for moving the wire feeder about the work place only. WARNING When suspending a wire feeder, insulate the ELECTRIC SHOCK CAN KILL. hanging device from the wire feeder enclosure. • Turn the input power OFF at the disconnect switch or fuse box HIGH FREQUENCY PROTECTION before attempting to connect or disconnect input power lines, out- put cables or control cables. CAUTION • Only qualified personnel should perfor
Краткое содержание страницы № 12
A-3 A-3 INSTALLATION ANALOG CONTROL CAbLE K1797-xx The control cable connecting the wire feeder to the power source is specially made for the welding envi- ronment. The wire feeder power requires overcurrent protec- tion. Connect the wire feeder only to power sources where the overcurrent protection is no more than 15 amps. Do not use more than 100 ft. (30.5 m) of control cable between the wire feeder and power source. Wire Feeder Power Source A J A J K I B I K B H N L L C H N C G G M D M D
Краткое содержание страницы № 13
A-4 A-4 INSTALLATION SHIELDING GAS CONNECTION CAbLE CONNECTIONS WARNING There is one circular connector for the gun trigger on the front of the LN-25™ PRO. CYLINDER may explode if damaged. • Keep cylinder upright and chained to support. Function Pin Wiring • Keep cylinder away from areas where it may be 5-pin trigger A Trigger damaged. connector for B Not used • Never lift welder with cylinder attached. push-guns C Common • Never allow welding electrode to touch cylinder. only. D Not used
Краткое содержание страницы № 14
A-5 A-5 INSTALLATION WIRE DRIVE CONFIGURATION 8. Connect the shielding gas hose to the new gun bushing, if required. (See Figure A.2) 9. Rotate the gun bushing until the thumb screw hole CHANGING THE GUN RECEIVER aligns with the thumb screw hole in the feed plate. bUSHING Slide the gun receiver bushing into the wire drive and verify the thumb screw holes are aligned. WARNING 10. Tighten the socket head cap screw. 11. Insert the welding gun into the gun bushing and ELECTRIC SHOCK can kill. tig
Краткое содержание страницы № 15
A-6 A-6 INSTALLATION 1. Squeeze the release bar on the retaining collar and PRESSURE ARM ADJUSTMENT remove it from the spindle. WARNING 2. Place the spindle adapter on the spindle, aligning the spindle brake pin with the hole in the adapter. ELECTRIC SHOCK can kill. • Turn the input power OFF at the weld- 3. Place the spool on the spindle and align the ing power source before installation or adapter brake tab with one of the holes in the back changing drive rolls and/or guides. side of the s
Краткое содержание страницы № 16
Wire Feed Module E SAE 400 with CV adapter S Pipeliner 200D Without Wire Feed module ngine Driven welder with AE’s Without CV Adapter Electrode Work LN-25™ PRO Work clip Classics B Eagle 10,000 Plus Cig Red’s C Power Source A-7 A-7 INSTALLATION POWER SOURCE TO LN-25™ PRO CAbLE CONNECTION DIAGRAMS ACROSS THE ARC SET-UPS CC Power Sources with Output Terminals Always Hot (See Figure A.5) CC Power Source Classics Ranger 250 GXT Wire Feed Module Work Work clip FIGURE A.5 SAE 400 with CV adapter D
Краткое содержание страницы № 17
DC-655 Air V Ranger 250, 250 LPG Ranger 305G, 305D Ranger 10,000 Ranger 3 Phase R C Ranger 225 C Va anger 225GXT ommander 300 Vn -4 ta antage 500 0g 0e 300, 400, 500 Jumper Electrode Work LN-25™ Pro Work clip A-8 A-8 INSTALLATION CV Power Sources with Stud Connectors and no Remote/Local Switch. (See Figure A.7) Place CV/CC switch in the feeder in the "CV" position. FIGURE A.7 CV-400 DC-655 Ranger 250, 250 LPG Jumper Ranger 305G, 305D LN-25™ Pro Work Work clip CV 305 V350-Pro Electrode LN-25™
Краткое содержание страницы № 18
C C CV V V- - -3 3 20 0 55 0 0 Electrode Work LN-25™ PRO Work clip Jumper A-9 A-9 INSTALLATION CV Power Source with Twist-Mate Connectors and no Remote/Local Switch. (See Figure A.9) FIGURE A.9 Jumper CV-250 CV-300 LN-25™ PRO Electrode CV-305 Work clip Work K# Description Place CV/CC switch in the feeder in the "CV" position. K2613-1 LN-25™ PRO K2613-2 LN-25™ PRO Extra Torque KP1695-XX KP1696-XX Drive Roll Kit KP1697-XX See Magnum Literature Welding Gun CV power Source K1841- Welding Cable
Краткое содержание страницы № 19
b-1 b-1 OPERATION GRAPHIC SYMbOLS THAT APPEAR ON SAFETY PRECAUTIONS READ AND UNDERSTAND ENTIRE SECTION THIS MACHINE OR IN THIS MANUAL bEFORE OPERATING MACHINE. INPUT POWER WARNING • ELECTRIC SHOCK CAN KILL. Unless using COLD FEED fea- ON ture, when feeding with gun trig- ger, the electrode and drive mechanism are always electri- OFF cally energized and could remain energized several sec- onds after the welding ceases.. • Do not touch electrically live part or electrode WIRE FEEDER with skin or w
Краткое содержание страницы № 20
b-2 b-2 OPERATION General Functional Description DEFINITION OF WELDING TERMS The LN-25™ PRO as designed is a simple, robust feeder. Standard features include a calibrated wire WFS feed speed dial, 2 step/trigger interlock switch, CV-CC • Wire Feed Speed switch, Gas Purge and Cold Feed. CC RECOMMENDED PROCESSES • Constant Current • GMAW • FCAW CV • Constant Voltage PROCESS LIMITATIONS GMAW • Gas Metal Arc welding • GMAW-P procedures must be qualified by the cus- tomer. SMAW • Across-the-Arc mod