Thank you for your purchase of a Spectra Newport system. Properly installed it will provide years of trouble free service. Please pay attention to the installation instructions and the sys- tem layout. Like any piece of mechanical equipment the system will require inspection and service from time to time. Do not place the components in inaccessible areas that will pre- vent proper maintenance. If you are having a dealer install the system for you, review the location of the components to make
Краткое содержание страницы № 4
4
Краткое содержание страницы № 5
Table of Contents Part 1 Page Number Installation Getting Started ................................................................................................................................................ 7 Installation Basics ........................................................................................................................................... 8 Component Placement ................................................................................................
Краткое содержание страницы № 6
6
Краткое содержание страницы № 7
Getting Started Unpack the system and inspect it to make sure that it has not been damaged in shipment. Refer to the shipping list for your system to make sure you have received all of the compo- nents listed. Do not discard any packaging until you have found and identified all of the parts. The small installation parts are listed on the cellophane bags’ pick list. We will not be held responsible for shortages and or freight damage that are not reported within thirty days of the
Краткое содержание страницы № 8
Installation Basics Thruhull Not Supplied. • Read the directions! • Avoid tight hose bends and excessive runs. • Use heavy gauge wire. • Install feed pump as low as possible. • Use a dedicated thruhull with scoop type strainer. Flow Thru-hulls It is mandatory that a dedicated 3/4” to 1” forward facing scoop type intake thru-hull and seacock be installed. Install the intake for the system close to the middle and as far below the water line as possible. Thru-hulls in the bow area
Краткое содержание страницы № 9
Component Placement Refer to the Plumbing Diagrams Strainer Mount the strainer in an accessible area close to the intake through- hull that can handle water spillage during service. Extra care during assembly must be taken to avoid air leaks from the strainer. Use the supplied “Quick Block” and wire tie for mounting. Fresh Water Flush Module The fresh water flush module may be located in any convenient location near the Feed pump module. It should be mounted with the filte
Краткое содержание страницы № 10
Clark Pump/Membrane Module Pressure Relief Valve The membrane maximum temperature specification is 120F. This module must be installed in an area that maintains a temperature below 120F (50C). A cool location is preferable. It may be placed as high in the boat as you desire. Make sure that the area around and under the pump does not have any water sensitive equipment. Water will be spilled during any repairs or if a leak occurs. Be sure you will have access to the pressure relief
Краткое содержание страницы № 11
Remote Control Panel The remote control panel can be mounted anywhere that’s dry and convenient. Cut a 4-9/16” (116 mm) wide by 2-7/8” (68mm) high opening for the panel. Locate in an area that is easily visible and easy to manipulate the buttons. Use only Spectra approved remote cable. The cable is not standard LAN cable or phone cord. Plumbing From the inlet thru hull to the boost pump module and from the boost pump module to pump module inlet use supplied clear 3/4 (19mm) spiral
Краткое содержание страницы № 12
System Piping schematic From the Clark pump brine dis- charge connector use the supplied 5/8 (15.9mm) clear braided vinyl hose to the brine overboard fitting. Mount the pressure gauge in the low pressure inlet gauge tee. Use the 1/2 inch nylon tubing between the Use the 1/2inch braided hose pump module Outlet between the Flush module and and the Clark Pump the Feed Pump Module Flush water from ship’s pressure water system 25 psi (2bar) minimum From the Boost Pump to the 20 micro
Краткое содержание страницы № 13
Note! When plumbing the Newport Pump Module route the feed water so that the front cover may be opened without removing the hose or tubing. Leave room on this side for attaching tubing and operat- ing the manual Feed water inlet from boost button on the diver- pump. Leave enough extra sion valve. length in this hose to allow the front cover to be moved aside. Flush water Inlet From Flush Module Feed Water Inlet from Filters Product Water Outlet to Tank Feed Water Outlet
Краткое содержание страницы № 14
Product Water tubing Product water tubing is 1/4 “ (6.3mm) parker tubing. See the Parker tube fitting assembly dia- gram next page. Product water goes from the membrane into the pump module manifold where it passes through the flow meter, the salinity sensor and the diversion valve. If the salinity is good the diversion valve energizes and the product goes to the tank from the manifold product outlet. If the diversion valve is not energized the product goes back into the feed water.
Краткое содержание страницы № 15
Quick Disconnect Fitting Brine Discharge Route the Brine discharge from the quick disconnect fitting to a location above the waterline using the supplied 5/8 hose. Fresh Water Flush Run a feed line from the domestic cold pressure water system to the 1/2 hose barb on the fresh water flush assembly. This needs to be pressurized when the boat is unattended for the fresh water flush system to function properly. The domestic fresh water pump must be able to deliver 1.5 gallons
Краткое содержание страницы № 16
Parker Tube Fitting Assembly Procedure Spacer Single grab ring for 1/4" & 3/8" tube O-ring Use 2 grab rings for 1/2" tube Body Nut Tubing Step 1: Dissemble fitting components 1/2" max Step 2: Install the Nut first then use the bevelled side of the Spacer to push the Grab Ring onto the tube no more than 1/2". Slip the O-ring over the tube to hold the Spacer in place. If the Grab Ring is pushed too far, trim back the tube so about 1/4" of tube extends past the O-ring. Step 3: Gently fit
Краткое содержание страницы № 17
Wiring Identify cables that are connected to the Newport Control System. Newport MkII Systems have a Power Inlet harness with a terminal block, a 50’(15M) cable with connectors is supplied for the MPC-5000 control display and a two concuctor boost pump power cable. Boost pump cable 50’ (15M) cable with Power inlet harness with connectors for the MPC- terminal block 5000 control display 17
Краткое содержание страницы № 18
Wiring (continued) Mount the main power terminal block in a junction box or on a bulkhead adjacent to the feed pump module. Make sure that this is a dry location well above bilge level and not subject to wa- ter spray. Route the control cable through the boat to the MPC display location. Be careful not to damage the connector or get it wet. Plug this into the back of the control. Connect the red and black Boost Pump wires to the corresponding red and black conductors in the Boost Pu
Краткое содержание страницы № 19
WIRE SIZE CHART Newport MkII 12V DC System Wiring Wire Length FT. Meters AWG. SQ MM 10 3 10 6 15 4.5 8 10 20 6.1 6 16 25 7.6 4 25 30 9.4 4 25 35 10.6 4 25 40 12 2 35 45 14 2 35 50 15 2 35 MkII 24V Meters AWG. SQ MM 10 3 12 4 15 4.5 10 6 20 6.1 8 10 25 7.6 8 10 30 9.4 8 10 35 10.6 6 16 40 12 6 16 45 14 6 16 50 15 4 25 Wire length for a pair of wires is measured from source circuit breaker or fuse to control terminal block. 19
Краткое содержание страницы № 20
MPC Remote Control Display Panels There are currently two types of display options available: Liquid Crystal Diode (LCD) display, which is dark lettering on a backlit background, or Vacuum Florescent Display (VFD), which are bright characters on a dark background. The VFD display brightness can be adjusted using the Programming Function detailed in Part 2 of this manual. The displays must be mounted in a protected location, out of direct sunlight, and away from spray or dripping water. Com