Getting Started Guide
PSA Series Spectrum Analyzers
This manual provides documentation for the following instruments:
E4440A (3 Hz - 26.5 GHz)
E4443A (3 Hz - 6.7 GHz)
E4445A (3 Hz - 13.2 GHz)
E4446A (3 Hz - 44 GHz)
E4447A (3 Hz - 42.98 GHz)
E4448A (3 Hz - 50 GHz)
Manufacturing Part Number: E4440-90284
Supersedes: E4440-90274
Printed in USA
March 2006
© Copyright 2001-2006 Agilent Technologies, Inc.
Краткое содержание страницы № 2
Notice The information contained in this document is subject to change without notice. Agilent Technologies makes no warranty of any kind with regard to this material, including but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. The following safety symbols a
Краткое содержание страницы № 3
Table of Contents Contents 1. Installation and Setup Initial Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Turning on the Analyzer for the First Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Firmware Revision . . . . . . . . . . . . .
Краткое содержание страницы № 4
Contents 4 Table of Contents
Краткое содержание страницы № 5
Installation and Setup 1 Installation and Setup 5
Краткое содержание страницы № 6
Installation and Setup This chapter provides the following information that you may need when you first receive your spectrum analyzer: “Initial Inspection” on page 7 “Power Requirements” on page 9 “Turning on the Analyzer for the First Time” on page 13 “Printer Setup and Operation” on page 18 “Protecting Against Electrostatic Discharge” on page 21 “Running Internal Alignments” on page 17 “Safety Information” on page 22 Agilent Technologies Performance Spectrum Analyzer (PSA)
Краткое содержание страницы № 7
Installation and Setup Installation and Setup Initial Inspection Initial Inspection Inspect the shipping container and the cushioning material for signs of stress. Retain the shipping materials for future use, as you may wish to ship the analyzer to another location or to Agilent Technologies for service. Verify that the contents of the shipping container are complete. The following table lists the items shipped with the analyzer. Item Description Accessories IntuiLink Toolbar software, CD-
Краткое содержание страницы № 8
Installation and Setup Initial Inspection NOTE If you purchased one or more optional measurement personalities, the related guides for the options you ordered are included. Service documentation is not included in the standard documentation set. See “Options” on page 65 for information on ordering. If There Is a Problem If the shipping materials are damaged or the contents of the container are incomplete: Contact the nearest Agilent Technologies office to arrange for repair or replacement
Краткое содержание страницы № 9
Installation and Setup Installation and Setup Power Requirements Power Requirements The only physical installation of your Agilent spectrum analyzer is a connection to a power source. Line voltage does not need to be selected. This analyzer does not contain customer serviceable fuses. WARNING Failure to ground the analyzer properly can result in personal injury. Before turning on the analyzer, you must connect its protective earth terminals to the protective conductor of the main power cabl
Краткое содержание страницы № 10
Installation and Setup Power Requirements Table 1-1 Power Requirements 1 Description Specification Voltage, Frequency 100 to 120 Vrms, 50/60/400 Hz 220 to 240 Vrms, 50/60 Hz Power Consumption, On Base Fully Loaded < 260 W < 450 W Power Consumption, Standby < 20 W 1. For greater detail, refer to the Specifications Guide. AC Power Cord The analyzer is equipped with a three-wire power cord, in accordance with international safety standards. This cable grounds the analyzer cabinet when connected t
Краткое содержание страницы № 11
Installation and Setup Installation and Setup Power Requirements Table 1-2 AC Power Cords Chapter 1 11
Краткое содержание страницы № 12
Installation and Setup Power Requirements Battery Information The analyzer uses a Lithium Polycarbon Monofloride battery to power the analyzer clock. The battery is located on the CPU board. You can order the service documentation for Agilent spectrum analyzers through your Agilent Sales and Service office. The documentation is described under “Options” on page 65. NOTE If the analyzer’s clock does not keep time when powered off, the problem is the battery. See “Returning an Analyzer for Se
Краткое содержание страницы № 13
Installation and Setup Installation and Setup Turning on the Analyzer for the First Time Turning on the Analyzer for the First Time ❏ Plug in the power cord. WARNING If this product is to be energized via an external auto transformer for voltage reduction, make sure that its common terminal is connected to a neutral (earthed pole) of the power supply. CAUTION The analyzer is shipped with a a transportation disk inserted in the disk drive to prevent damage to the disk drive during transporta
Краткое содержание страницы № 14
Installation and Setup Turning on the Analyzer for the First Time ❏ If using LAN, set the IP address of the analyzer to an appropriate number for your network; one that the network recognizes, but that is not yet in use. (Consult your local IT group): — Press System, Config I/O, and note the IP address. — If the current address is not appropriate, press IP Address and use the keypad to change it. — Connect the LAN cable to the LAN connector located on the rear panel of your analyzer (see “Re
Краткое содержание страницы № 15
Installation and Setup Installation and Setup Turning on the Analyzer for the First Time procedure (on the Agilent Web site) to reinstall the firmware and completely reconfigure your instrument. Refer to “Managing Security” in Chapter 4 of the “User’s and Programmer’s Reference, Volume 1.” When you are totally satisfied with the configuration of your PSA analyzer, enable the Secure Memory Erase option by pressing System, Security, Security, Enabled. The security mode will then be enabled the
Краткое содержание страницы № 16
Installation and Setup Firmware Revision Firmware Revision To view the firmware revision of your analyzer, press System, More, Show System. If you call Agilent Technologies regarding your analyzer, it is helpful to have this revision and the analyzer serial number available. TIP You can get automatic electronic notification of new firmware releases and other product updates/information by subscribing to the Agilent Technologies Test & Measurement E-Mail Notification Service for the PSA a
Краткое содержание страницы № 17
Installation and Setup Installation and Setup Running Internal Alignments Running Internal Alignments Each time the analyzer is powered on, the internal alignment routine runs automatically. The analyzer was shipped from the factory with the Alignments mode set to Auto. This setting enables the alignment routine to run automatically either every 24 hours, or when the internal analyzer temperature changes ±3°C. NOTE When the Alignment routine runs, you will hear the attenuator settings chan
Краткое содержание страницы № 18
Installation and Setup Printer Setup and Operation Printer Setup and Operation A printer can be connected to your analyzer if it is equipped with an external I/O interface. Supported printers accept Hewlett-Packard Printer Control Language Level 3 (PCL3) or 5 (PCL5). Refer to the documentation or specifications supplied with your printer, or contact the manufacturer to identify your printer’s language. Equipment IEEE 1284 compliant printer cable. Supported and tested printers are liste
Краткое содержание страницы № 19
Installation and Setup Installation and Setup Printer Setup and Operation Printer Models Language Color Type Capable HP Professional Series 2500CM PCL3 yes Chapter 1 19
Краткое содержание страницы № 20
Installation and Setup Printer Setup and Operation Interconnection and Setup 1. Turn off the printer and the analyzer. 2. Using an IEEE 1284 compliant parallel printer cable, connect the printer to the analyzer parallel I/O interface connector on the rear panel (see “Rear-Panel Features” on page 29). 3. Turn on the analyzer and printer. 4. On the front panel, press Print Setup, then press the Printer Setup menu key. 5. Select the printer language and color capability appropriate for your pri