Dampers, Actuators and Valves
control your environment with honeywell
DAmPS, er v AveS l AnD ActuA torS
Application And Selection Guide
Краткое содержание страницы № 2
How to use this guide Additional product information All pages in this literature are constructed in one of two ways: t o find more detailed information on the individual products included in this document, go to: http://customer.honeywell.com For unassembled product: and use the search text box to quickly locate product specific As a reference, pictures will represent the valves and actuators content. separately; and part numbers are highlighted in blue. t o order a complete product one
Краткое содержание страницы № 3
Table Of COnTenTs Resilient seat butterfly Valves Section 1: DCa & Damper selection 2-Way electrically-actuated Control ......................................66 Dampers ......................................................................................8 3-Way electrically-actuated Control ......................................68 DCa ...........................................................................................12 2-Way Pneumatically-actuated Control ...........................
Краткое содержание страницы № 4
Table Of COnTenTs flanged Cage Valve Section 3: submittal sheets (COnT.) V5051a ...............................................................................139 MP958 ................................................................................104 flanged Globe Valve Modutrol IV Motor V5011a, b ..........................................................................140 M4185; M8185 ...................................................................105 V5013b, C ......................
Краткое содержание страницы № 5
Table Of COnTenTs Pneumatic Valve actuator Parts and accessories ....................196 foot Mounted Motor accessories ............................................198 Damper and Valve linkage accessories ...................................200 Section 8: Competitive Cross Reference Direct Coupled actuator ...........................................................202 Control ball Valve 2-Way Valve .......................................................................220 2-Way Valve + non-spr
Краткое содержание страницы № 6
6
Краткое содержание страницы № 7
Selection GUiDe Section 1: DCa & Damper selection Dampers ......................................................................................8 DCa ...........................................................................................12 fire and smoke ..........................................................................14 7
Краткое содержание страницы № 8
Damper and actuator sizing Use the following guidelines to determine the actuator quantity and Determining Damper Actuator torque torque requirements for your damper configuration. Requirements Determine Damper Actuator locations Use the following procedure to determine the required torque for your damper. Use the following configuration to determine the amount of actuator locations your damper will require. nOTe: Damper area is measured using the H and W dimensions. single section ≤ 48 x 7
Краткое содержание страницы № 9
DcA & DAMpeR Selection Damper and actuator sizing Table 2. approximate industry standard damper lb-in. per sq ft value. Face Velocity (fpm)/ Static Pressure (in. wc Leakage Damper 500/ 1000/ 1500/ 2000/ 2500/ Blades 1 2 3 4 5 Low Parallel 4 7 10.5 12 14 Low Opposed 3 5 7.5 8.5 10 Standard Parallel 3 4.5 6.5 7 8 Standard Opposed 2 3 4.5 5 6 Damper Sizing Dampers can be sized using two different methods; actual sizing and nominal sizing. When actual sizing is used the damper dimensions will
Краткое содержание страницы № 10
Damper and actuator sizing HVAC performance depends largely upon airflow, and Honeywell Volume Control Dampers are built for both improved airflow and heavy-duty use. Honeywell has long been the leading source for airflow control, with Volume Control Dampers that meet AMCA-certified Air Performance Standards, the highest established standards for commercial control dampers. Designed to minimize leakage, Honeywell dampers will give you efficient, trouble-free operation for years to come. Stan
Краткое содержание страницы № 11
DcA & DAMpeR Selection Damper and actuator sizing Standard Round Dampers Custom Dampers D690 and DM7600 Round Dampers. The 6” to 16” round dampers Need a custom damper? Contact the Take-Off Service. Below is a are used in zoning systems to control airflow in a round duct. These sample list of the products we frequently quote. dampers come with neoprene and silicone seals for tight close off Custom Rectangular Dampers and low leakage. The DM7600 includes an actuator that is already attached to
Краткое содержание страницы № 12
Direct Coupled actuators DIReCT COUPleD aCTUa TORs QUICK seleCTIOn GUIDe Precise, reliable performance. lasting value. e ase Improve Installation Time of installation. everything you look for in direct- • Self-centering shaft adapter provides mounting coupled actuators hinges on quality. and quality flexibility and greater clamping force. engineering is what makes Honeywell’s complete • C o m m o n w i r i n g a m o n g f a m i l i e s f o r e v e r y s i g n a l lin
Краткое содержание страницы № 13
DcA Selection Direct Coupled actuators sPRInG ReTURn Running time power Supply control input/output Auxiliary Knob Adj. Internal Order Approximate Spring 0/2-10 3 kOhm Feedback Zero SPDT Minimum Specification Area of Damper Drive Return 24 120-230 VA Rating Vdc, NTC, (0/2-10 and Auxiliary Position Number (4.5 lb-in/sq. ft.) (seconds) (seconds) Vac/dc Vac (Running) On/Off Floating 3-Position Vdc) Span Switches Potentiometer S03 Series (3 Nm, 27 lb-in) MS8103A1030 6 45 <25 • • 0 MS8103A113
Краткое содержание страницы № 14
fire & smoke actuators Key Features and Benefits Honeywell’s complete line of two-position, fast-acting spring- return actuators meet all of your needs for fire and smoke control • Integral spring r etur n that ensur es the pr oper level of tor que applications. all models are designed to meet the Ul-555 and • P a t e n t e d d e s i g n t h a t e l i m i n a t e d l i m i t s w i t c h e s , r e d u c i n g p o w e r Ul-555s high temperature requirements for fire
Краткое содержание страницы № 15
Val Ve Selection Section 2: Valve Selection Control Valve Applications .........................................................17 Threaded and Flanged Globe Valves 2”-3” Control Valve Selection Criteria ..................................................18 With Tandem Linked Direct Coupled Actuators ....................46 2-Way ...................................................................................18 Flanged Globe Valves 2 ½ - 3” 3-Way .........................................
Краткое содержание страницы № 16
16
Краткое содержание страницы № 17
Val Ve Selection Control Valve Applications Control Valve Applications 17 Fan Coil/Zone Valve
Краткое содержание страницы № 18
Control Valve Selection Criteria 2-Way Unitary Globe Cartridge Cartridge Fan Coil Threaded Flanged Cage Globe Attribute Specification VU52 VU53 VCzA/B V58x2 V5011N... V5011F V5011G V5011A V5011B VGF2xS 1/2" [DN15] • • • • • 3/4" [DN20] • • • • • 1" [DN25] • • • • 1 1/4" [DN32] • • 1 1/2" [DN40] • 2" [DN50] • Pipe Size 2 1/2" [DN65] • • • • 3" [DN80] • • • • 4" [DN100] • • • 5" [DN125] • • • 6" [DN150] • • • Other (maximum size) Sweat • • • • NPT Internal Thread • • • • • • • Pipe
Краткое содержание страницы № 19
Val Ve Selection Control Valve Selection Criteria 2-Way Globe Control Ball Butterfly Pressure-Balanced Threaded Flanged Resilient Seat Attribute Specification V5862A3 VGF2xP VBN2 VBF2 VFF1 VFF2 1/2" [DN15] • 3/4" [DN20] • 1" [DN25] • • 1 1/4" [DN32] • • 1 1/2" [DN40] • • 2" [DN50] • • • Pipe Size 2 1/2" [DN65] • • • • 3" [DN80] • • • • 4" [DN100] • • • • 5" [DN125] • • • • 6" [DN150] • • • • Other (maximum size) 20" [DN500] Sweat NPT Internal Thread • • Pipe Fittings Inverted Flare
Краткое содержание страницы № 20
Control Valve Selection Criteria 3-Way Unitary Globe Cartridge Fan Coil Cartridge Globe Threaded Flanged Cage Attribute Specification VU54 VCzM/N V58x3 V5863A3 V5013N... V5013B V5013C VGF3xLD VGF3xEM 1/2" [DN15] • • • • 3/4" [DN20] • • • • 1" [DN25] • • • • 1 1/4" [DN32] • • • 1 1/2" [DN40] • • 2" [DN50] • Pipe Size 2 1/2" [DN65] • • • 3" [DN80] • • • 4" [DN100] • • • • 5" [DN125] • • • • 6" [DN150] • • • • Other (maximum size) Sweat • • • NPT Internal Thread • • • • • Pipe Fittin