Краткое содержание страницы № 1
I N S T A L L A T I O N
I N S T R U C T I O N S
CARE AND USE MANUAL FOR:
CLASSICAL WALL RANGE HOODS
Models covered by these instructions:
SU1, SUE1, SU2, SU3, SUE3, SU4, SU5, SU7,
SU18,SU22, SU23,SU25, SU26, SU31, SU36, SU39
* * * B E F O R E I N S T A L L A T I O N * * *
ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED
DURING SHIPPING
* * * S H I P P I N G D A M A G E * * *
MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT
Telephone (Toll Free)
Краткое содержание страницы № 2
W A R N I N G S Thank you for purchasing a Sirius Range Hood. Please read all the instructions in this manual before installing the appliance. Save these instructions for future reference. The appliance is not intended for use by young children or infirm persons without supervision. Young children should be supervised to ensure they do not play with the appliance. If the range hood is vented, the air so vented must be ducted into a dedicated duct that is not showed with any other
Краткое содержание страницы № 3
TABLE OF CONTENTS BEFORE YOU BEGIN 1 DUCTING 1 External Venting Requirements 1 Duct Run Calculation 1 ELECTRICAL 2 Electrical Supply 2 INSTALLATION 3 Positioning the Range Hood 3 Marking the Fixing Holes for the Range Hood 3 Fixing the Main Support Bracket 3 Chimney Installation 4 Hanging the Range Hood 4 Connecting Electricity and Ducting 5 Connecting Chimneys 5 Re-Circulating Requirements 6 OPERATING PROCEDURES 6 General Advice 6 Functions 7 MAINTENANCE 7 Cleaning the Filter 7 Cleaning the Ho
Краткое содержание страницы № 4
B E F O R E Y O U B E G I N The manufacturer declines all BEFORE YOU BEGIN: responsibility in the event of failure It is advisable to test run the to observe the instructions given range hood before installation. here for installation, maintenance and suitable operation of the Please read this entire manual and product. The manufacturer further ensure that you are fully conversant declines all responsibility for injury with the requirements and limitations due to negli
Краткое содержание страницы № 5
hood is 100’. Calculate your duct run Maximum Run by measuring linear feet and adding 6” or 3 1/4 x 10” duct 100 FT the elbows, transitions and caps Deduct based on the table alongside. Each 90 elbow used 15FT Each 45 elbow used 9FT The ducting connection to the hood Each 6” or 3 1/4 x 10” duct must be in line with the central vertical axis of the range hood 1” Transition used 1FT away from the back wall on which Each 3’1/4 x 10” to 6” the hood is to be mounted. Transition used
Краткое содержание страницы № 6
I N S T A L L A T I O N Gently tape the template to the wall Positioning the Range Hood making sure it has no creases or folds (use a tape that will not Determine the center point of the damage the wall finish). There are range hood. This is generally the three hole positions shown for the center of the range. Make a mark wall bracket. Using a sharp object, on the wall a minimum of 25” above mark the wall through the template the top of an electric range. If the at the cent
Краткое содержание страницы № 7
the lower two holes, as the range The bracket fixed onto the back of hood will cover these holes once the range hood will drop into the hung on the Support Bracket (“S”). channel on the top of bracket “S” on the wall. Ensure the hood is securely Chimney Installation engaged into the support bracket - the range hood must clip in behind the extended lip on the Support Locate the bracket (item Y) and Bracket (“S”). position it with the vertical axis (marked on the wall earlier) running
Краткое содержание страницы № 8
Connecting Electricity and Ducting Figure 9 Figure 8 Figure 7 Connecting Chimneys Please refer to the Electrical Supply section on page 2 for the required Remove the protective covering from location of the electrical supply. the decorative chimney and carefully slide the sections together. CAUTION: Make sure the power is turned off at source. Make electrical Do not remove the tape strips from connections (refer to Fig 7). inside the chimney as this protects the telescoping chimney
Краткое содержание страницы № 9
Figure 11 Figure 12 Figure 13 A short length of ducting is Re-Circulating Requirements connected between the exhaust outlet on the fan and the deflector to If the unit will be used in direct the air back into the kitchen re-circulating mode (refer Figure 11), through the vents at the top of the fit the deflector (refer Figure 12) with upper decorative chimney. the screws supplied to the upper telescope chimney. The carbon filter (supplied se
Краткое содержание страницы № 10
In the event of a range top grease Filter requires washing indicator (SU fire, observe the following: Models only): After 30 hours of use, all the buttons will light up to Switch OFF the range hood. Turn remind you that the grease filter off the cook top then smother flames should be cleaned. Follow the with a close fitting lid, cookie sheet instructions for cleaning filters in this or other metal tray. If the flames do booklet. Once the grease filters have not go out immedi
Краткое содержание страницы № 11
Cleaning the Filter Do not use abrasive cleaning agents as these will destroy the brushed The aluminium mesh filters should finish. be washed by hand or in the dishwasher as required. Damaged Light Bulb Replacement and worn filters must be replaced (If in doubt, call 866-528-4987) immediately. (Do not operate blower when filters have been removed). Turn blower and lights off. Make Allow filters to dry before replacing them, otherwise water will be drawn sure the lights are co
Краткое содержание страницы № 12
Three Year Limited Warranty WARRANTY SERVICE To qualify for warranty service, you must notify Sirius Range Hoods at the address stated below or call toll free USA or Canada 1-866-528-4987 and provide the model number, description of the fault or defect and original date of purchase. Sirius reserves the right to request proof of original purchase. Sirius will at its sole option and discretion replace products that arrive damaged through shipping, provided shipping damage is reported