Краткое содержание страницы № 1
30" (76.2 CM) AND 36" (91.4 CM)
SLIDE-OUT VENT RANGE HOOD
Installation Instructions and Use & Care Guide
HOTTE D'ASPIRATION AVEC MODULE DE
COMMANDE EXTRACTIBLE DE 30" (76,2 CM)
ET 36" (91,4 CM)
Instructions d’installation et Guide d’utilisation et d’entretien
Table of Contents/Table des matières.............................................................................2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
IMPORTANT:
Installer: Leave ins
Краткое содержание страницы № 2
TABLE OF CONTENTS TABLE DES MATIÈRES RANGE HOOD SAFETY .................................................................3 SÉCURITÉ DE LA HOTTE D’ASPIRATION ................................19 INSTALLATION REQUIREMENTS ................................................4 EXIGENCES D’INSTALLATION...................................................21 Tools and Parts ............................................................................4 Outillage et pièces..........................................
Краткое содержание страницы № 3
RANGE HOOD SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING.” These words mean: You can be killed or seriously injured if you don't immediately
Краткое содержание страницы № 4
INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. IMPORTANT: Observe all governing codes and ordinances. Read and follow the instructions provided with any tools listed Have a qualified technician install the range hood. It is the here. installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial Tools needed rating plate is located behind the le
Краткое содержание страницы № 5
Product Dimensions 30" (76.2 cm) model: 8" (20.3 cm) 36" (91.4 cm) model: 11" (27.9 cm) 4³⁄₈" (11.1 cm) 3¹⁄₄" (8.3 cm) 30" (76.2 cm) model: 26" (66.0 cm) 36" (91.4 cm) model: 32" (81.3 cm) FRONT OF 10" VENT HOOD (25.4 cm) ³⁄₈" (9.5 mm) 2³⁄₈" (6.0 cm) 2" 30" (76.2 cm) model: 13" (33.0 cm) 9¹⁄₂" (5.1 cm) (24.1 cm) 36" (91.4 cm) model: 16" (40.6 cm) 8" ¹⁄₄" (20.3 cm) (6.4 mm) Shelf extends 7" (17.8 cm) 1¹⁄₄" 1⁵⁄₈" (31.8 mm) 1" (41.3 mm) (25.4 mm) BACK OF ⁵⁄₈" to 2¹⁄₈" V
Краткое содержание страницы № 6
Makeup air Recommended Standard Fittings Local building codes may require the use of makeup air systems Vent Piece 3¹⁄₄" x 10" (8.3 cm x 25 cm) when using ventilation systems with greater than specified CFM of air movement. The specified CFM varies from locale to locale. 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft Consult your HVAC professional for specific requirements in your 90° elbow (1.5 m) area. Venting Methods The vent system needed for installation is not included. 3¹⁄₄" x 10" (8.3 cm x
Краткое содержание страницы № 7
Electrical Requirements A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is For GZ or IH model series: required. WARNING: To reduce the risk of fire or electrical shock, do not use this fan with any solid state speed control device. Do not ground to a gas pipe. For KWVU model series: Check with a qualified electrician if you are not sure the range This fan is suitable for use with solid state speed controls. hood is properly grounded. IMPORTANT: Observe all governing codes a
Краткое содержание страницы № 8
5. If the cabinet bottom is recessed above a support frame, Transfer measurement A and B to the cabinet back wall. wood filler strips need to be installed on the right and left Measure from the underside of the cabinet or wood filler sides of the cutout to provide sides of clearance for the strips, if used. Mark the cutout as shown. Use a saber saw or sliding screen. Wood filler strips should be flush with or keyhole saw to cut a rectangular opening for the vent. recessed ¹⁄₁₆"-¹⁄₈" (1.6 mm-
Краткое содержание страницы № 9
7. Install the vent system according to the method needed. Use 10. Measure the thickness of the cabinet floor, including the filler caulking to seal the exterior wall or roof opening. strips, if used. If the thickness is less than ⁵⁄₈" (15.9 mm), install wood filler strips that are a minimum length of 8. Determine wiring knockout. 5" (12.7 cm) onto the cabinet floor. The mounting bracket To wire through the top wiring knockout: adjusts from ⁵⁄₈" (15.9 mm) to 2¹⁄₈" (54 mm) for the wood filler
Краткое содержание страницы № 10
13. Place the vent hood on its back side on a protected surface. 2. Check that the front panel is parallel with the cabinet front when the screen is pushed in. Slide the screen forward. a) Slide the screen forward. Tighten the mounting bracket screws so that the vent hood is b) Pull the tabs to remove the filters. secured to the cabinet. c) Remove the terminal box cover. d) Close the screen. e) Slide the mounting brackets to the top position. A B A. Mounting bracket screw A B. Flat-blade
Краткое содержание страницы № 11
3. Connect the black wire of the power supply cable to the Recirculation installations: black wire in the hood with a twist-on connector. Connect the vent system to the hood vent opening. Seal the connection with clamps. Install Recirculation Kit (Part Number 883140) WARNING 1. Pull out on the range hood to expose the filters. 2. Remove the 2 metal filters. 3. Locate tabs “A” and slots “B” in the opening. This is where the filter will fit into place. Electrical Shock Hazard Electrically grou
Краткое содержание страницы № 12
Optional Front Trim Kits Front trim kits for matching the front panel to your range or cooktop color are available from your dealer. Install Front Trim Kit For ordering information see the “Assistance or Service” section. 1. Pull out on the range hood for easier access to the screws. 2. Remove the 3 mounting screws directly behind the front For 30" (76.2 cm) model series panel, and remove the front panel from the range hood. KWVU205: Part No. 4360201 (white) Part No. 4360203 (black) Part No. 4
Краткое содержание страницы № 13
GZ and IH Model Series B A C D A. Light switch B. Fan switch C. Indicator light D. Speed switch Operating the Fan Operating the Light 1. Slide the shelf forward. 1. Open the shelf about 1" (2.5 cm). 2. Move the fan switch to 1. 2. Move the light switch to the 1 position. 3. Move the speed switch to the desired setting. The light will be on each time the shelf is opened. The light can be used for a night light by opening the glass shelf about The speed may be increased, decreased, or turned off
Краткое содержание страницы № 14
WIRING DIAGRAMS KWVU Model Series WIRING BOX W G G 8 BS/28K–A120 BK LIGHT 120 VAC LINE IN 7F u BALLAST 6 K2 TRANS. 5 H K1 BK 1 4 FLUORESCENT 3 LAMP 2 FL S H K L W H FAN R LIGHT FAN R ON-OFF OFF 12 3 FLAT CABLE CONNECTOR PUSH BUTTON PANEL 14 CONNECTOR V V CONTROL BOARD OR BU BK BR V GY W W BK
Краткое содержание страницы № 15
GZ and IH Model Series BK OR BU GY 8 BS/28K–A120 BR V W LP 7 uF W BK LIGHT BK BK R R S FAN 120 VAC BK WBK LINE IN FLUORESCENT LAMP 15 WIRING BOX BK GG W BALLAST TRANS.
Краткое содержание страницы № 16
ASSISTANCE OR SERVICE Before calling for assistance or service, please check “Troubleshooting.” It may save you the cost of a service call. If In Canada you still need help, follow the instructions below. Call the Whirlpool Canada LP Customer Interaction Centre toll When calling, please know the purchase date and the complete free: 1-800-807-6777. model and serial number of your appliance. This information will Our consultants provide assistance with: help us to better respond to your reque
Краткое содержание страницы № 17
WHIRLPOOL CORPORATION MAJOR APPLIANCE WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Whirlpool Corporation or Whirlpool Canada LP (hereafter “Whirlpool”) will pay for Factory Specified Parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Whirlpool designated service company. This limited warranty a
Краткое содержание страницы № 18
® KITCHENAID VENTILATION WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, KitchenAid or KitchenAid Canada (hereafter “KitchenAid”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a KitchenAid designated service company. ITEMS KITCHENAID WILL NOT PAY FOR 1. Service cal
Краткое содержание страницы № 19
SÉCURITÉ DE LA HOTTE D’ASPIRATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte
Краткое содержание страницы № 20
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : AVERTISSEMENT - POUR D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : RÉDUIRE LE RISQUE D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES Ne jamais laisser un élément de surface fonctionner à INSTRUCTIONS SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait Utiliser cet appareil uniquement dans les applications pro