Краткое содержание страницы № 1
Indesit
HI561 IXUK
HI591 IXUK
Commercial Codes
28113 + 28114
Instruction Booklet
Aura
Краткое содержание страницы № 2
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa 2 aaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaa
Краткое содержание страницы № 3
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa INSTALLATION .......................................................................................................................... 4 Safety warnings .................................................................................................................................... 4 Components ......................................................................................................................................... 4 Instruction
Краткое содержание страницы № 4
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa INSTALLATION aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa This canopy hood is designed to be fixed to any rigid vertical surface, over a gas or electric hotplate and can be used either in the extraction mode (ducted to the outside) or in the recirculation mode (internal recycling). Safety warnings • Before commencing the installation, consideration should be given to the difficulties to be found during installation and to the bulky weight of t
Краткое содержание страницы № 5
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa Instructions for Installation For easy installation proceed as follows: • Fix the wall brackets and Splashback. • Fix the canopy. • Set the hood for recirculation or evacuation. • Connect the hood to the mains supply and ensure that it works properly. • Fix the telescopic metal frame. Fixing the wall brackets (and splashback) Ref. to Fig. 2a-b • Draw a vertical line on the wall, from the centre of the cooking appliance up to the ceiling, using a m
Краткое содержание страницы № 6
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa Note: ensure that the wall bracket (I) is levelled. The hood can be aligned or adjusted in height by rotating the adjustment screws (see below). • Mark on the wall the centres of the two keyholes of the bracket. Fixing the wall brackets item 2: • Place one of the two brackets (item 2 fig. 1) 15 mm from the ceiling or from a horizontal line drawn between the top of the adjoining wall cabinets, ensuring that the bracket is level and mark the centres
Краткое содержание страницы № 7
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa Ducting or Recirculation fitting Ducting fitting • The cooker hood can be ducted to the outside using either rigid or flexible fire retardant ducting of 120 or A 150 mm. The choice is left to the installer. When 120 mm ducting is to be used it will be necessary to install the reduction flange item A on the air outlet fig. 4. • The installer should provide suitable ducting and sealing material for the installation. • The cooker hood can also be duc
Краткое содержание страницы № 8
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa Electrical connection and working test • Before connecting to the mains supply ensure that the mains voltage corresponds with the voltage on the rating plate inside the hood. • Connect the cooker hood to the mains via a double pole switch which has 3 mm clearance between the contacts. • The appliance must be earthed. • Once the electrical connection has been completed, check that worktop illumination, motor and speed work properly. Fitting the tel
Краткое содержание страницы № 9
2 3 aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa USE aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa Safety warnings • Before carring out any kind of maintenance or cleaning, disconnect the hood from the mains supply. • The grease filters and the charcoal filter should be cleaned or replaced as recommended by the manufacturer or more frequently if the hood is used consistently over 4 hours per day. • When using a gas hob in connection with the cooker hood never leave the burners of the hob
Краткое содержание страницы № 10
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa MAINTENANCE aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa Regular maintenance and cleaning will ensure good performance and reliability, while extending the working life of the hood. Special attention should be paid to the grease filters and to the charcoal filters when the hood is used in the recirculation mode. Metal grease filters Cleaning The metal grease filter should be cleaned every two months with normal usage and can be cleaned in a di
Краткое содержание страницы № 11
aaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaa Worktop illumination Worktop illumination is provided by 2 Z Z 40W bulbs. To replace the lighting elements T T proceed as follows: • Remove the metal clips T. • The glass diffuser is kept in position by the retaining lugs Z. • Pull the glass diffuser slightly to one side until it disconnects from the lug on the other side (arrow 1), then pull slightly downwards (arrow 2) and slide in the opposite direction (arrow 3) until the glass diffuser can be
Краткое содержание страницы № 12
This appliance complies with European regulations on low voltages, EEC Directive 73/23 on electrical safety, and with the following European regulations: EEC Directive 89/336 on electromagnetic compatibility and EEC Directive 93/68 on EC marking. 436000718 01 020522