Краткое содержание страницы № 1
30" (76.2 CM) AND 36" (91.4 CM)
RETRACTABLE (POP-UP) DOWNDRAFT VENT SYSTEM
SYSTÈME DE VENTILATION RÉTRACTABLE (CLAPET) DE
30" (76,2 CM) ET 36" (91,4 CM) - ASPIRATION
PAR LE BAS
Installation Instructions and Use & Care Guide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JENNAIR (1-800-536-6247), or visit our website at www.jennair.com.
In Canada, call: 1-800-807-6777, or visit our website at www.jennair.ca.
Instructions d’instal
Краткое содержание страницы № 2
TABLE OF CONTENTS VENT SYSTEM SAFETY.................................................................2 VENT SYSTEM USE .....................................................................14 Operating Downdraft Vent .........................................................14 INSTALLATION REQUIREMENTS ................................................4 Tools and Parts ............................................................................4 VENT SYSTEM CARE......................................
Краткое содержание страницы № 3
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF A RANGE TOP WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC GREASE FIRE: SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: ■ Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ■ Use this unit only in the manner intended by the ignite. Heat oils slowly on low or medium settings. manufacturer. If you have questions, contact the manufacturer. ■ Always turn hood ON when c
Краткое содержание страницы № 4
INSTALLATION REQUIREMENTS Tools and Parts Location Requirements Gather the required tools and parts before starting installation. NOTE: Downdraft vent is installed directly behind the cooktop. Read and follow the instructions provided with any tools listed Install the downdraft vent first, then install the cooktop. here. IMPORTANT: Observe all governing codes and ordinances. ■ Have a qualified technician install the downdraft vent. It is the Tools Needed installer’s responsibility to comply wi
Краткое содержание страницы № 5
Product Dimensions Top trim widths: 30" (76.2 cm) 36" (91.4 cm) 13¹⁄₂" (34.3 cm) retractable vent height 1¹⁄₂" (3.8 cm) ³⁄₈" (0.95 cm) 27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent 5¹⁄₄"(13.3 cm) for 30" (76.2 cm) vent 8¹⁄₄"(21.0 cm) for 36" (91.4 cm) vent 28¹⁄₂" (72.4 cm) 13¹⁄₈" (33.4 cm) ³⁄₄ (1.9 cm) 16¹⁄₂" (42.0 cm) 10" (25.4 cm) 2¹⁄₈" (5.4 cm) As-Received Blower Reversed Blower Front of Front of Range Hood Range Hood 4³⁄₄" (12 cm) 10" 10" (25.4 cm) (25.4 cm)
Краткое содержание страницы № 6
Cabinet Dimension 10" (25.4 cm) A= ¹⁄₂" (12.7 mm) minimum 21⁵⁄₁₆" (54.1 cm) 21⁵⁄₁₆" (54.1 cm) Cutouts are for 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent system. Centerline of cooktop cutout Locate power supply junction box at lower left hand rear corner of the cabinet. NOTES: ■ See cooktop manufacturer’s instructions for cooktop cutout ■ Interior mounted blower systems connect with 3¹⁄₄" x 10" depth and width. (8.3 x 25.4 cm) rectangular or 6" (15.2 cm) roun
Краткое содержание страницы № 7
Countertop Cutout Dimensions Chart Venting Requirements IMPORTANT: Make sure there is proper clearance within the wall B or floor before making exhaust vent cutouts. D ■ Use heavy (rigid) metal vent. ■ Venting system must terminate to the outside. C ■ Do not terminate the vent system in an attic or other enclosed area. A ■ Do not use 4" (10.2 cm) laundry-type wall caps. ■ Do not install 2 elbows together. ■ Do not use plastic or metal foil vent. ■ The length of vent system and number of elbows
Краткое содержание страницы № 8
INSTALLATION INSTRUCTIONS Venting Methods Determine which venting method is best for your application. Island Location - Vent System Installed Under a Concrete Vent system can terminate either through the wall or floor. Slab Using PVC Sewer Pipe Island Location Front (Standard) Mounted Blower Motor Front (Standard)-Mounted Rear-Mounted Blower B Blower Motor Motor A D E M C F G H A L A K J I Rear Mounted Blower Motor A. Down vent B NOTE: For island locations, a front- or rear-mounted
Краткое содержание страницы № 9
To calculate the length of the system you need, add the Example Vent System equivalent feet (meters) for each vent piece used in the system. C 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 6 ft (1.8 m) Vent Piece Rectangular B A 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 5.0 ft 90° elbow (1.5 m) 2 ft (0.6 m) D 3¹⁄₄" x 10" (8.3 cm x 25.4 cm) 12.0 ft flat elbow (3.7 m) A. Blower motor C. 90° elbows B. Transition D. Back draft damper The following example falls within the maximum vent length of 3¹⁄₄" x 10" (8.3 cm x 25.4
Краткое содержание страницы № 10
5. Attach the right and left end caps to the vent box. Place the Bottom Venting: tab into the mounting slot at each end of the downdraft vent NOTE: If installing the vent damper in the down position, a wall or as shown and push down to lock into place. roof cap with a damper at the exit end of the vent system is required. A ■ Downdraft vent is shipped with blower in down venting B position so no modification is required. ■ If rear mounting of the blower motor is not required, go to the “
Краткое содержание страницы № 11
Rear Mounting - Blower Motor NOTE: Optional blower motor rear mounting position (opposite 5. Remove the screws from the wire mounting plate. side) for island cabinet locations. The blower motor box assembly can be moved to the opposite side (rear) of the vent box. 1. Remove 7 screws from the mounting flanges of the blower motor box. Front View A A A B C A. Screws B. Wire mounting plate C. Blower motor box 6. Hold the wire mounting plate and push the grommet out of A the mounting plate. A A
Краткое содержание страницы № 12
Complete Installation NOTE: The downdraft vent system is supplied with a 3¹⁄₄" x 10" 3. Determine which direction (front or rear) the home power (8.3 x 25.4 cm) back draft damper and a 6" (15.2 cm) round vent supply cable will enter the terminal box. Remove the transition with damper. Refer to “3¹⁄₄" x 10" (8.3 x 25.4 cm) back appropriate knockout from the front or rear panel and install a draft damper” or “6" (15.2 cm) round vent transition with ¹⁄₂" (12.7 mm) UL listed or CSA approved cond
Краткое содержание страницы № 13
7. Fasten the lower support legs to the cabinet floor with screws 4. Connect the 2 white wires together using UL listed wire (not provided). connectors. F C D E A B A. Screw (not provided) 8. Tighten the lower support legs screws. A Make Electrical Connections A. Green or green and yellow D. Black wires ground wire E. UL listed or CSA approved B. White wires conduit connector WARNING C. UL listed wire connectors F. Downdraft vent wiring 5. Connect the 2 black wires together using UL listed wir
Краткое содержание страницы № 14
VENT SYSTEM USE The retractable downdraft vent system is designed to remove smoke, cooking vapors and odors from the cooktop area. Operating Downdraft Vent ■ For best results, the vent should be operating before cooking To Use: is started. 1. Push and hold the button on top of downdraft vent for a few ■ If you use large or tall utensils, place them on the large rear seconds. (This slight delay helps avoid unintentional raising of element or burner surface. the vent during cleaning of the
Краткое содержание страницы № 15
WIRING DIAGRAM Y 7 Motor Specifications Y/G Power supply 120 VAC BR Frequency 60 Hz W attage rating S50 420 W Amperage 3.7 A 9 Motor Resistance BU/W 21.6 Ohms BU/R 18 Ohms BU/GY 14.3 Ohms BU/BK 9.8 Ohms 8 2 1 BK BK 1 GY GY R R W W BR BR BR 1 Blower Switch Operation Contact Function 1 - 3 OFF N.O. Com 1st Speed 3 - 5 BR 5 N.C. 2nd Speed 5 - 7 8 - 10 3rd Speed GY GY 10 - 12 4th Speed N.O. N.O. Com Com R 3 4 Component Layout N.C. N.C. GY Num. Description GY 1 Filter microswitch 2 Filter microswitch
Краткое содержание страницы № 16
ASSISTANCE OR SERVICE When calling for assistance or service, please know the purchase date and the complete model and serial number of your In Canada appliance. This information will help us to better respond to your Call the dealer from whom your appliance was purchased, or call request. Jenn-Air at 1-800-807-6777 to locate an authorized service company. When calling, please know the purchase date and the If you need replacement parts complete model and serial number of your appliance. B
Краткое содержание страницы № 17
® JENN-AIR MAJOR APPLIANCE WARRANTY ONE YEAR LIMITED WARRANTY For one year from the date of purchase, when this major appliance is operated and maintained according to instructions attached to or furnished with the product, Jenn-Air brand of Whirlpool Corporation or Whirlpool Canada LP (hereafter “Jenn-Air”) will pay for factory specified parts and repair labor to correct defects in materials or workmanship. Service must be provided by a Jenn-Air designated service company. This limited warra
Краткое содержание страницы № 18
Notes 18
Краткое содержание страницы № 19
SÉCURITÉ DU SYSTÈME DE VENTILATION Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité. Ce symbole d’alerte de sécurité vous signale les dangers potentiels de décès et de blessures graves à vous et à d’autres. Tous les messages de sécurité suivront le symbole d’alerte
Краткое содержание страницы № 20
IMPORTANTES INSTRUCTIONS DE SÉCURITÉ AVERTISSEMENT : POUR MINIMISER LE RISQUE AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D'UN FEU DE GRAISSE SUR LA CUISINIÈRE : D'INCENDIE, CHOC ÉLECTRIQUE OU DOMMAGES CORPORELS, RESPECTER LES INSTRUCTIONS ■ Ne jamais laisser un élément de surface fonctionner à SUIVANTES : puissance de chauffage maximale sans surveillance. Un renversement/débordement de matière graisseuse pourrait ■ Utiliser cet appareil uniquement dans les applications provoquer une infla