Краткое содержание страницы № 1
Owner's Manual
Manual del Propietario
®
ROOM AiR CONDITIONER
ACONDICIONADOR DE AIRE DE VENTANA
Model, Modelo 580.72184
Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.
www.sears.com
Краткое содержание страницы № 2
Features ................................................. 10 TABLE OF CONTENTS ........................2 Using the Air Conditioner ....................... 10 WARRANTY ..............................................2 Display ................................................... 11 SAFETY .....................................................3 MAINTENANCE .....................................12 Important Safety Instructions ...................... 3 Air Filter Cleaning ................................
Краткое содержание страницы № 3
IMPORTANT SAFETY INSTRUCTIONS The safety instructions below will tell you how to use your room air conditioner to avoid harm to yourself or damage to your ROOM AIR CONDITIONER. FOR YOUR SAFETY Do not store er use gasoline or other flammable Avoid fire hazard or electric shock. vapors and liquids in the vicinity of this or any other Do not use an extension cord or an adapter plug. appliance. Read product labels for flammability and Do not remove any prong from the power cord. other warnings. PREV
Краткое содержание страницы № 4
OBSERVE ALL LOCAL CODES AND ORDINANCES. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG. ELECTRICAL GROUND IS REQUIRED ON THIS APPLIANCE. For 230/208 volt 60Hz, AC only, !5A fused and Electrical Shock Hazard properly grounded electrical supply is required. Plug into a grounded 3 prong outlet. A time delay fuse or time delay circuit breaker Do not remove ground prong. is recommended. Use a dedicated circuit, Do not use an adapter. serving only this appliance. Do not use
Краткое содержание страницы № 5
INSTALLATION HARDWARE INSTALLATION REQUIREMENTS Your air conditioner will install into standard double hung windows with actual clear opening widths of A B C D E 29 to 4t inches (737mm to 1041mm) (FIG, 1) Lower sash must open sufficiently to allow a clear vertical opening of 18 inches (457mm). Side louvers and the rear of the air conditioner must have clear air space to allow enough airflow through the F G H I J K condenser for heat removal. The rear of the unit must be outdoors, not inside a bu
Краткое содержание страницы № 6
_] Insert the side curtain(ITEM A) into the upper guide INSTALLATION and lower guide of the air conditioner. Fasten the curtains Pick a location which will allow you to blow the cold to the unit with screws (ITEM E). air into the area you want, Windows used for installation must be strong enough to support the weight of the air conditioner. Good installation with special attention to the proper position of the unit will lessen the chance that service will be needed. When cooling more than one ro
Краткое содержание страницы № 7
_Pull the bottom window sash down behind the ° Connect a drain elbow of 9/16" inside diameter to upper guide until they meet. the drain pipe. • Connect a drain hose of 9/16" inside diameter to the NOTE: drain elbow, (Drain hose is not supplied.) • Do not pull the window sash down so tightly that the movement of sliders is restricted. Attach the cabinet to the window inner sill by driving the screws (ITEM F) I I Drain through the cabinet into window inner sill. • The cabinet should be installed w
Краткое содержание страницы № 8
_i_ FRONT INSTALLATION Top of wood strip should be approximately 3/4" higher than the storm window frame to help Install the front grille onto the cabinet as follows: condensation to drain properly to the outside. • Hook upper tabs of front grille into slots on the • Install a second wood strip (approximately 6" tong by cabinet top.(FIG. 17) 11t2"wide and same thickness as first strip) in the • Push front grille's tips toward the cabinet in order center of the outer sill flush against the back o
Краткое содержание страницы № 9
HOW AND WHY Your room air conditioner provides the following You may hear air functions to make hot weather living more movement from the i an comfortable: fan. ° Cools and circulates room air. Unit Vibration -- -Compressor • Lowers humidity by removing excess moisture. The unit may vibrate The modern high • Filters out summertime dust, dirt, and some and make noise efficiency compressor airborne impurities, because of poor wall may have a high The air conditioner performs these functions by or
Краткое содержание страницы № 10
FEATURES USING THE AIR CONDITIONER _]_]_ To reduce the risk of fire, electric shock, or injury to persons, read the important SAFETY instructions section before operating this appliance To begin operating the air conditioner after installation, follow these steps: 1. Plug in the air conditioner.(To prevent electrical hazards, do not use an extension cord or an adapter plug.) 2, Set the exhaust vent to the CLOSE position. 3, Set the TEMP Control to the coolest setting, 4. Set the MODE Control at
Краткое содержание страницы № 11
AIR CONDITIONER FEATURES The controls featured in this manual are representative of the many models available. Your model may look slightly different. 5 off _ On OFF e 4 ° 6 Auto Swing 3° 2" =_ _ MED _ HIGH 1 ° _ °9 LO MED FAN COOL ° LOW COOL TEMP MODE TEMP AUTO SWING The thermostat will automatically control the ON : Air swing is operated while Operation knob temperature of the room. Select a higher number for is set to the Cool position. lower room temperature. The temperature is selected by t
Краткое содержание страницы № 12
AIR FILTER CLEANING HOW TO REMOVE THE The Air Filter will become dirty as it removes dust FRONT GRILLE from the inside air, It should be washed at least • Open the inlet grille downward. every 2 weeks. If the Air Filter remains full of dust, the air flow will decrease and the cooling capacity - Remove the screw securing the Front Grille, will be reduced, possibly damaging the unit. • Push the grille up from the bottom and pull the top . Pull the inlet grille forward, grasping both tabs, and of t
Краткое содержание страницы № 13
BEFORE CALLING FOR SERVICE Check the following list to be sure a service call is really necessary. A quick reference to this manual may help you avoid an unneeded service call. THE AIR CONDITIONER WILL NOT OPERATE Check if.,. Then... Wallplugdisconnected. Pushplugfirmlyintowalloutlet. Housefuseblownorcircuitbreakertrippe& Replace fusewitht_me delaytypeorresetcircuitbreaker. MODEselectorisOFFposition. TurnMODEselectorto thedesiredCOOLsetting, Unitwasturnedoffandthenontooquickly. Turnunitoffandwai
Краткое содержание страницы № 14
Room Air Conditioner To order Parts call Toll Free Model No. 580.72184200 1-800-4-MY-HOME®(1-800-469-4663) CAUTION: Use the Kenmore part number on all orders, not the illustration number. CABINET & FRONT GRILLE ASS'Y 3-A 11/01 - 14 -
Краткое содержание страницы № 15
580.72184200 CAUTION: Use the Kenmore part number on all orders, no_jtthe illustration number. CABINET & FRONT GRILLE ASS'Y POS. NO PART NO DESCRIPTION 1 - A 3530AR1182A FRONT GRILLE 2 - A 3530AR1531A INLET GRILLE 3 - A 5230AR1327A AIR FILTER ASS'Y 4 - A 5990AR2972A VAN E 5 - A 3091AR6057C CABIN ET ASS'Y 6 - A 2H00858E UPPER GUIDE 7 - A 3850A20423F LABEL, ENERGY 3828A20145E MANUAL OWNER'S # = Functional Parts * = Non-illustrated Parts - 15 - 11/01
Краткое содержание страницы № 16
580.72184200 CAUTION: Use the Kenmore part number on all orders, no__tt the illustration number. CONTROL BOX ASS'Y 10-B 14-B 2-B 12-B 1-B 16-B 4-B ,L 8-B 3-B 7-B 6-B 13-B 11-B 15-B 11/01 - 16-
Краткое содержание страницы № 17
580.72184200 CAUTION: Use the Kenmore part number on all orders, not the illustration number. CONTROL BOX ASS'Y POS. NO PART NO DESCRIPTION 1 - B # 4994AR1587A CONTROL BOX 2 - B 2H01109L THERMOSTAT 3 - B 2H00598E ROTARY SWITCH 4 - B 6120AR2194D SH CAPACITOR 5 - B # 2H00677Q POWER CORD ASS'Y 6 - B 4941AR7134C KNOB ASS'Y 7 - B 2H01316C ROCKER SWITCH 8 - B 3721A20035W POWER, CONTROL 9 - B 4H01762A CLIP CORD 10 - B 6631AR2687A CONNECTOR ASS'Y 11 - B 2H01102A SYNCHRONOUS MOTOR 12 - B 4520AR4386A LINK
Краткое содержание страницы № 18
580.72184200 CAUTION: Use the Kenmore part number on all orders, not the illustration number. AIR HANDLING & CYCLE PARTS 15-C 22-C 17-C 4-C 13-C 11-C 11-C 16-C 9-C 14-C 11/01 - 18-
Краткое содержание страницы № 19
580.72184200 CAUTION: Use the Kenmore part number on all orders, not the illustration number. AIR HANDLING & CYCLE PARTS POS. NO PART NO DESCRIPTION 1 - C 3041A30002K BASE PAN WELD ASS'Y 2 - C 5238AR1584A AIR GUIDE 3 - C 3072AR1583A SCROLL 4 - C 4790AR1558A BARRIER 5 - C 4900AR7265A DAMPER 6 - C 4960AR1596A MOTOR MOUNT 7 - C # 4681AR6033K MOTOR ASS'Y 8 - C 3040AR6160A INSULATION, EPS 9 - C # 5834AR1599A BLOWER 10- C # 5900AR1508A FAN 11 - C 3H02932C CLAMP SPRING 12 - C 4998AR1597A SHROUD 13 - C
Краткое содержание страницы № 20
580.72184200 CAUTION: Use the Kenmore part number on all orders, no___tt the illustration number. COMPRESSOR PARTS 9-D 8-D 7-D 12-D 14-D O-D 5-D 10-D 2-D 4-D 3-D .._ 11/01 - 20 -