Краткое содержание страницы № 1
K K F F R R - - 3 3 2 2 0 0 8 8 G G W W / / A A E E
S SP PL LIIT T T TY YP PE E A AIIR R C CO ON ND DIIT TIIO ON NE ER R
I I N N S S T T R RU U C CT T I I O O N N
M M A A N N U U A A L L
I IN NS ST TA AL LL LA AT TI IO ON N
Hisense Corporation
Краткое содержание страницы № 2
This air conditioner provides with cooling, heating, and drying functions. Details of the functions are below; refer to these descriptions when using the air conditioner. Compact Size Air Sweep Control This model is smaller than its predecessors and This function moves a flap up and down in the air yet offers the same capabilities. outlet, directing air in a sweeping motion around the room and providing comfort in every corner. Microprocessor Controlled Operation
Краткое содержание страницы № 3
Contents Pardon not to inform you if the contents of the manual changes. Page Alert symbol 1 Caution statements 2 Composition of the air conditioner 3 Operation guide 8 Care and cleaning 15 Tips for energy saving 17 Troubleshooting 17 Schematic diagram 18
Краткое содержание страницы № 4
Caution Statements 1.We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the installation WARNING instructions provided with the unit. 2.Before installation, check if the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate. WARNING 3.Do not install the air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhou
Краткое содержание страницы № 5
Composition of the Air Conditioner 1.Diagram of Structure Air intake grille INDOOR UNIT Air outlet Drain hose Remote control Refrigerant tubes unit OUTDOOR UNIT Air outlet The appearance of the appliance may differ from some pictures. This air conditioner consists of an indoor unit and an outdoor unit. You can NOTE control the air conditioner with the remote control unit. Air from the room is drawn into this section and passes Air Intake through air filters which remove dust. Condition
Краткое содержание страницы № 6
2.Introduction of the Indoor ControI Unit INDOOR UNIT OPERATING lamp TIMER lamp POWER lamp IMPORTANT: POWER HI POWER HIGH POWER TIMER lamp Avoid using radio equipment such as mobile phone near OPERATING (within 1m) the indoor unit. Some radio equipment may ON/OFF cause maIfunction of the unit. If the troubIe happens, dis- connect power and restart the air conditioner after a few REMOTE CONTROL receiver ON/OFF button minutes. REMOTE CONTROL
Краткое содержание страницы № 7
3.Introduction of Display Displayed when setting temperature T TE EM MP P S S E E T T Displayed when transmitting data A C Displayed when temperature is shown Displayed when temperature setting is at the upper or lower allowable limits Displayed when one-hour Displayed when Night Setback is 1HOUR OFF timer is enable running Displayed when main unit sensor is in HOUR use A Displayed when setting timer ON A OFF Symbols (1) Operation mode (3) Set temperature 16-30 When set to 28
Краткое содержание страницы № 8
H.P. 4.Introduction of the Remote control Unit 4.Introduction of the Remote control Unit SENSOR Transmitter T T E E M M PS P S E E T T A C 1HOUR 1 С ʱ HOUR A ON Display OFF A FAN 1 HR TEMP SPEED 1 HR. TIMER button FAN SPEED selector button ON/OFF button HIGH POWER button TEMP.setting button FLAP MODE MODE selector button FLAP button ON OFF TIMER ON/OFF button SLEEP SET CANCEL SLEEP button TIMER SET/CANCEL button A/C SENSOR ACL ACL button A/C SENSOR button (Cover closed) Battery compartmen
Краткое содержание страницы № 9
Remote Control Unit(continued) TIMER ON button :The air conditioner starts at the set time. TIMER OFF button :The air conditioner stops at the set time. TIMER SET/CANCEL button This button is used to set/cancel the time at which you wish the air conditioner to go on or off. MODE selector button Use this button to select AUTO, HEATING, DRY or COOLING mode. (AUTO) :When this setting is selected, the air conditioner calculates the difference between the A set t
Краткое содержание страницы № 10
Operation Guide HOW TO INSTALL BATTERIES 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction m arked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. + + - - - - + + Sliding cover Replace the batteries when the remote control unit's display fails to light, or when the NOTE ! remote control unit cannot be used to change the air conditio
Краткое содержание страницы № 11
H.P. Operation with the Remote Control Unit(continued) C A A FAN 1 HR TEMP SPEED STEP 4 STEP 3 STEP 2 FLAP MODE STEP 1 STEP 5 ON OFF SLEEP SET CANCEL ACL A/C SENSOR Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is NOTE in the ON position. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired. Press the MODE selector button
Краткое содержание страницы № 12
Adjusting the Fan Speed A. Automatic A Simply set the FAN SPEED selector to the position. A A microprocessor in the air conditioner automatically controls the fan speed when the mode is selected. When the air conditioner starts operating, the difference between the room temperature and the set temperature is detected by the microprocessor which then automatically switches the fan speed to the most suitable level. B. Manual If you want to adjust fan speed manuall
Краткое содержание страницы № 13
H.P. H.P. Night Setback / Simultaneous Use Energy Saving T TE EM MP P S SE ET T C A ¡ñ Night Setback Mode A Night Setback Mode is used for saving energy. Press the SLEEP button in operation. The mark appears in the display. To release the night FAN setback function, press the SLEEPbutton again. 1 HR TEMP SPEED NOTE This function loses in automation or airflow mode. FLAP MODE ON OFF SLEEP SET CANCEL ACL A/C SENSOR HIGH POWER Operation This operation makes highe
Краткое содержание страницы № 14
H.P. H.P. Using the 12-Hour ON and OFF Timer 1.TIMER ON mode After the length of time set for TIMER ON elapses, the unit begins operating. (Example) The display depicted at left indicates that the air conditioner will begin operating in three hours. Setting Procedures: C Press the MODE button and set the desired operation mode and STEP 1 HO HOUR UR press the ON/OFF operation button. STEP 2 Press the timer ON button to set the time at which you want operation to begin. The time can b
Краткое содержание страницы № 15
H.P. Using the 1-Hour OFF Timer This function causes the unit to operate for one hour and then stop, regardless of whether the unit is on or off when this button is pressed. 1HOUR 1HOUR The indicator in the display indicates that this function is operating. C 1HOUR 1 С ʱ Setting procedure: A Regardless of whether the unit is operating or stopped, press the 1 HR .TIMER button. A Appears in the display 1HOUR 1HOUR . FAN 1 HR TEMP SPEED Cancellation procedure: Pr
Краткое содержание страницы № 16
Special Remarks Heating ( ) Operation Heating performance Because this air conditioner heats a room by drawing on the heat of the outside air (heat pump system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this air conditioner, use another heating appliance in conjunction with it. When the outdoor temperature is low, frost or ice may from in the heat exchanger Defrosting coil,
Краткое содержание страницы № 17
Operation without the Remote Control Unit HI POWER POWER TIMER OPERATING ON/OFF button ON/OFF If you have lost the remote control unit or it has trouble, follow the steps below. 1.When the air conditioner is not running If you want to turn on the air conditioner, pressing the ON/OFF button once. 2.When the air conditioner is running If you want to turn off the air conditioner, pressing the ON/OFF button once. Pressing buttons cannot last too long time, or the air conditioner may N
Краткое содержание страницы № 18
Care and Cleaning (continued) Anti-Mold Filter The anti-mode filter behind the air intake grille should be checked and cleaned at least once every three weeks. How to remove the 1.Grasp both ends of the air intake grille and pull it out and up. anti-mold filter 2.Push the anti-mold filter up slightly, and then pull it down. Air intake grille Anti-mold filter Anti-Mold Filter Use a vacuum cleaner to remove light dust. If there is sticky dust on the filter, Cleaning wash the filter in lukewarm
Краткое содержание страницы № 19
Tips for Energy Saving Do not Block the air intake and outlet of the unit. If they are obstructed, the unit will not work well, and may be damaged. Let sunlight directly into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer time to cool the room. Always try to keep the air filter clean. (Refer to Care and Cleaning .)A Do clogged filter will impair the performance of the unit. To preven
Краткое содержание страницы № 20
Schematic Diagram 1. Refrigerant Flow Diagram Outdoor unit Indoor unit Compressor Accumulator Wide tube Wide service valve 4-way valve Capillary Narrow service Cooling cycle tube Capillary Narrow tube Heating cycle Check valve 2. Permitted ambient temperature for the air conditioner is following:-7 ~+43 . 3. Electric Wiring Diagram 1 1 2 2 3 3 4 4 5 5 INDOOR OUTDOOR UNIT UNIT 18 Heat exchanger Heat exchanger