Installation Instructions BEFORE YOU BEGIN WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL Read these instructions completely and carefully. SHOCK OR INJURY TO PERSONS, OBSERVE THE • IMPORTANT – Save these instructions for FOLLOWING: local inspector’s use. A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the • IMPORTANT – Observe all governing codes manufacturer. and ordinances. B. Before servicing or cleaning unit, switch power off at • Note t
Краткое содержание страницы № 3
Installation Instructions CONTENTS Step 1, Determine Ductwork and Wiring Locations .... 10 Step 2A, Install Hood Onto Wall ................................... 11 Product Dimensions ......................................................... 3 Step 2B, Install Hood Beneath Soffit ............................ 12 Installation Clearances ..................................................... 4 Step 3, Connect Ductwork ............................................. 13 Optional Duct Cover Accessories ....
Краткое содержание страницы № 4
SOFFIT SOFFIT Advance Planning INSTALLATION CLEARANCES OPTIONAL DUCT COVER These vent hoods are designed to be installed onto a ACCESSORIES wall or beneath a soffit or cabinet. Standard and Full-Width decorative duct covers are Installation with Warming Shelf available in 6" and 12" heights. Duct covers may be • Hoods must be installed 32" Min., 38" Max over any stacked, in various combinations, to conceal the type cooking surface when warming shelf is used. ductwork running from the top of the
Краткое содержание страницы № 5
Advance Planning DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES These vent hoods must be installed 30" min. to Restaurant-Style Hoods Restaurant-Style Hoods 36" max. above the standard 36" high cooking without Warming Shelf Installed with Shelf Installed1 surface. When installed with the warming shelf, *Possible *Possible allow 32" min. to 38" max. clearance. The exact Actual Hood Hood Ceiling Installation 6" Duct 12" Duct Installation 6" Duct 12" Duct hood installation height is determin
Краткое содержание страницы № 6
Advance Planning ADVANCE PLANNING POWER SUPPLY Ductwork Planning IMPORTANT – (Please read carefully) • These vent hoods are equipped for 10" round ductwork. For best performance, use 10" round WARNING: ductwork on the 48" wide hoods. 30" and 36" hoods FOR PERSONAL SAFETY, THIS APPLIANCE MUST may be transitioned to 8" round. BE PROPERLY GROUNDED. • This hood may be vented vertically through upper cabinets, soffit or ceiling. A duct transition piece is AVERTISSEMENT– POUR DES supplied for vertica
Краткое содержание страницы № 7
Advance Planning Equivalent Quantity Total DUCT FITTINGS Duct Piece Length* Used Length Use this chart to compute maximum 10" round permissable lengths for duct runs to to 8" round 5 ft. outdoors. For best results, use 10" diameter duct. Round, 1 ft. straight (per foot length) Note: Do not exceed maximum permissable equivalent lengths! 90° elbow 8" Dia. 52 ft. 10" Dia. 24 ft. Maximum recommended duct length for these hoods: 150 feet 45° elbow 8" Dia. 31 ft. Flexible ducting: 10" Dia. 14 ft. If f
Краткое содержание страницы № 8
Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) 1/4" pivoting hex socket Hammer Electric or battery operated drill Duct tape Key Hole Saw Wire cutter/stripper and 1/8", 3/8" bits Pencil and tape measure 10" round metal duct, length to Safety glasses suit installation. Wire nuts Phillips and flat Spirit level blade screwdrdivers Flashlight Strain relief for junction cover. Step ladder 120V 60Hz. 15 or 20 Amp, Pliers Metal Snips Saber saw 2-wire with ground. Properly or Sawsal
Краткое содержание страницы № 9
Installation Preparation PARTS PROVIDED Locate the parts packed with the hood. Wood Support Duct Transition with Original Screws with Damper 2 Stainless Steel Grease Filters (3 filters with 48" models) Heat Lamp (2 with 48" models) 2 Implement Rods and 4 Stand-offs Backguard Allen Wrench For Implement Rods Grease Tray Warming Shelf HARDWARE 4 Phillips head screws to PACKAGE secure the duct transition to Locate and check contents. the hood outlet on the top. Screws shown actual size. Note: Hardwa
Краткое содержание страницы № 10
Installation Instructions STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS • Use a level to draw the cooktop centerline location. Draw the line to ceiling height. 9-7/8" • Measure desired distance from the bottom of the hood to the cooking surface. Top of Hood Note: If you are installing the hood with duct covers, be sure to read “Using Duct Cover Accessories” page 7. Exact installation height may be determined by use of one or more duct covers. Wood 22-1/2" Support • Determine bottom 20"
Краткое содержание страницы № 11
Installation Instructions STEP 2A INSTALL HOOD ONTO WALL IMPORTANT: Framing must be capable of supporting up to 150 lbs. SKIP THIS STEP IF INSTALLING BENEATH A SOFFIT OR Install Transition Onto Top of Hood CABINET, GO TO STEP 2B. Duct • Locate at least 2 vertical studs at the wood support. Transition • Center the supplied wood support, left to right and below the 20" marked line. IMPORTANT: Remove shipping tape from damper and check that damper moves freely. • Place the duct transition piece ov
Краткое содержание страницы № 12
Installation Instructions STEP 2B Alternate Mounting Method INSTALL HOOD TO SOFFIT OR BENEATH CABINETS SKIP THIS STEP IF USING WALL MOUNTING IMPORTANT: Soffit framing must be capable METHOD of supporting up to 150 lbs. When necessary, the hood may be installed so that it is supported by the soffit. Install Transition Onto Top of Hood • The soffit should be constructed with 2 x 4’s. • Determine the installation location on the wall. • Continue the centerline forward on the bottom of the Duct cab
Краткое содержание страницы № 13
Installation Instructions STEP 3 CONNECT DUCTWORK STEP 5 INSTALL DUCT COVERS • Install ductwork, making connections in direction of Note: For easier handling, remove cardboard insert airflow as illustrated. after film is peeled off. • Secure joints in ductwork with sheetmetal screws. • Wrap all duct joints with Remove protective film from duct covers. If more than duct tape for an airtight seal. one duct cover is used, secure each piece together with • Use duct tape to seal the screws provided
Краткое содержание страницы № 14
Installation Instructions • Insert the filter into the opening and drop into the STEP 7 INSTALL FILTERS bottom. Raise filter to the top and lock into place. • Drop grease tray into the hood. The rear tabs should engage the slots in the hood track. • To remove the filters, grasp the latch, pull the filter up and lift out. This hood can be installed with the STEP 8 INSTALL BACKGUARD AND SHELF warming shelf and backguard together or with the warming shelf or backguard alone. INSTALL BACKGUARD: I
Краткое содержание страницы № 15
Installation Instructions STEP 9 INSTALL SHELF “ONLY” STEP 10 INSTALL IMPLEMENT RODS • Remove shelf packaging and protective film. • If installing the shelf alone, without the backguard, place shelf against the bottom of the hood and mark screw hole locations “B” on the wall. • Drill two 1/8" pilot holes. • If drill did not enter studs, enlarge holes to 3/8". • Insert wall anchors into enlarged holes. Remove screws from wall anchors. • Install two shoulder screws into holes “D” in the Screw
Краткое содержание страницы № 16
Note: While performing installations described in this book, safety glasses or goggles should be worn. ® For Monogram local service in your area, call 1.800.444.1845. Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice. GE Consumer & Industrial GE Appliances Pub. No. 49-80152-4 General Electric Company Louisville, KY 40225 11-07 JR ge.com Printed in Italy ©2007 GE Company 16