Краткое содержание страницы № 1
Installation
Instructions
Downdraft Vent Systems
PVB37
PVB67
PVB94
PVB98
ZVB30
ZVB36
31-10728
09-09 JR
1
Краткое содержание страницы № 2
Safety Information befoRe you beGIN WARNING: To ReDuce The RISk Read these instructions completely and carefully. of f IRe, elec TRIc Shock o R INju Ry To pe RSo NS, obSeRVe The folloWING. • IMpoRTANT – Save these instructions A. Use this unit only in the manner intended by for local inspector’s use. the manufacturer. If you have questions, contact • IMpoRTANT – Observe all governing the manufacturer. codes and ordinances. b. Before service or cleaning unit, switch power off
Краткое содержание страницы № 3
Design Information coNTeNTS Design Information Ductwork Product Dimensions ................................................................3 Duct Fittings ............................................................................. 10 Accessories..................................................................................3 Installation Instructions Advance Planning ............................................................... 4, 5 Step 1, Install Downdraft Vent ..........................
Краткое содержание страницы № 4
Design Information ADVANce pl ANNING Remote Switch before you begin, you must: The 30" and 36" Monogram models and the 36" 1. Review countertop dimension illustrations to Profile model have a separate raise/lower switch. be sure you will have enough flat countertop Plan to install the switch in a convenient location surface. outside of the vent/cooktop cutout. 2. Check to be sure that the total countertop depth required (including minimum cutout to front edge Downdraft Vent and cooktop cuto
Краткое содержание страницы № 5
Design Information clearances Ductwork Prepare ductwork to vent to the outdoors. • The downdraft system with blower, motor and ductwork will occupy the cabinet below • Use the shortest and straightest duct run possible. the countertop and cooktop. • The maximum permissible length for duct run • The blower/motor assembly can be located is 150 feet. below the cabinet floor. The assembly will fit • Refer to “Duct Fittings” chart to calculate between 16" floor joists. Order JXRB67 for in
Краткое содержание страницы № 6
Installation preparation cuT ouTS AND cle ARANceS • Measure carefully when cutting the countertop. • Refer to cooktop installation instructions to Make sure sides of the opening are parallel and be sure that models fit into the base cabinets rear and front cuts are exactly perpendicular being used. to the sides. • Draw lines on the countertop to follow as • Measure to be sure there is room for clearances a cutting guide. Measure and mark cooktop to the front edge of the countertop. a
Краткое содержание страницы № 7
Installation preparation cle ARANceS cAuTIoN: Wall coverings, countertops and cabinets should withstand 200° heat generated by any cooktop. Gas - 6" to 12" Electric - 2" Clearance to Side Walls 13" 13" Max. Max. 682Dia40 a 30" 30" Min. Min. 18" 18" Min. Min. 2" Min. to 6" or 12" Min. Wall When to Wall When 2" Min. to 6" or 12" Min. Installed Installed Wall When to Wall When Installed Installed electric cooktop clearances When Installed Gas cooktop clearances When Installed 682Dia39 682D
Краткое содержание страницы № 8
Installation preparation Do Not Locate Gas or Electrical poWeR Supply Connections Within Shaded Area WARNING: FOR PERSONAL SAFETy, ThIS APPLIANCE MUST bE PROPERLy GROUNDED. 29-1/2" Remove house fuse or open circuit breaker before beginning installation. Electrical Outlet Do not use an extension cord or adapter plug 12" Above with this appliance. Follow National Electrical Code Cabinet Floor or prevailing local codes and ordinances. 34" for 36" Models 28-1/2" for 30" Models This downd
Краткое содержание страницы № 9
Installation preparation VeNTING opTIoNS Loosen Screws to Adjust 3-1/2" to • The downdraft vent is shipped with the Left or Right discharge outlet pointing straight down and can be changed to the left or right side. • The blower outlet is sized for 3-1/4" x 10" and can be transitioned to 6" round. Side-to-Side Adjustments: The entire blower mounting plate can be adjusted 3-1/2" to the left or right. This will help to align vent discharge to house ductwork. Discharge Down (As Suppl
Краткое содержание страницы № 10
Installation preparation Use this chart to Total DucT Equivalent Quantity Equivalent compute maximum fITTINGS Duct Piece Dimensions Length* Used Length permissible lengths for duct runs to 1 ft. Use 3-1/4" x 10" 6" round, (per foot outdoors. duct. It can straight length) transition to 6" No Te: Do not exceed 1 ft. round. 3-1⁄4" x 10" (per foot maximum permissible straight length) equivalent lengths! 6" Downdraft Vent: 90° elbow 12 ft. 150' maximum e
Краткое содержание страницы № 11
Installation Instructions 1 INSTAll DoWNDRAf T VeNT 2 INSTAll DucTWoRk Place the downdraft vent into the countertop • The downdraft blower system is designed for use cutout, against the back side. with 3-1/4" x 10" ductwork. It can be transitioned to 6" round. bracket location for right-side or straight- • Ductwork MUST be vented to the outside—never down blower discharge in a crawl space, attic or other enclosed space. • 6" PVC duct should be used when installing under a concrete slab.
Краткое содержание страницы № 12
Installation Instructions 3 INSTAll coNTR ol SWIT ch (on some models) Skip this step if there is no separate control switch. WARNING: Disconnect electrical power from unit before beginning switch installation. Failure to do so could result in personal injury or damage to the electrical controls. connect control Switch to Remote harness Determine the location for the control switch. • Thread the remote harness through the 1/2"-dia. The wiring lead is 68" long. hole and attach the ha
Краткое содержание страницы № 13
Installation Instructions 4 coNNecT poWeR cle ANING Plug power cord into properly grounded receptacle. painted or Stainless Steel Surfaces To clean the stainless steel or painted surfaces, use warm, sudsy water or a stainless steel cleaner or polish. 5 INSTAll fIl TeRS, check opeRATIoN The filters should be washed by hand. Do not clean filters in the dishwasher. • Press and hold the ON/OFF pad on the control to raise the vent. • Slip fingers into the vent holes. Lift the vent straight
Краткое содержание страницы № 14
Notes 14
Краткое содержание страницы № 15
Notes 15
Краткое содержание страницы № 16
NOTE: While performing installations described in this book, safety glasses or goggles should be worn. NOTE: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specifications are subject to change without notice. 31-10728 09-09 JR 16
Краткое содержание страницы № 17
NOTA: Mientras efectúa las instalaciones descriptas en este libro, deben utilizarse gafas o lentes de seguridad. NOTA: La mejora de los productos es un esfuerzo continuo para General Electric. Por lo tanto, los materiales, la apariencia y las especifi caciones pueden sufrir cambios sin previo aviso. 31-10728 09-09 JR 16
Краткое содержание страницы № 18
Notas 15
Краткое содержание страницы № 19
Notas 14
Краткое содержание страницы № 20
Instrucciones de instalación 4 CONECTE LA ENERGÍA LIMPIEZA Enchufe el cable de energía en un tomacorriente Superfi cies pintadas o de acero inoxidable con adecuada conexión a tierra. Para limpiar superfi cies pintadas o de acero inoxidable, utilice agua tibia jabonosa o un limpiador o lustrador para acero inoxidable. Los fi ltros deben lavarse a mano. No lave los fi ltros 5 INSTALE LOS FILTROS Y CONTROLE en el lavavajillas. EL FUNCIONAMIENTO • Presione y sostenga el botón ON/OFF (enc