Thanks for buying a BISSELL Vacuum We’re glad you purchased a BISSELL CleanView Multi Cyclonic vacuum. Everything we know about floor care went into the design and construction of this complete, high-tech home cleaning system. Your BISSELL CleanView Multi Cyclonic canister vacuum is well made, and we back it with a limited one year warranty. We also stand behind it with a knowledgeable, dedicated Consumer Services department, so, should you ever have a problem, you’ll receive fast, con
Краткое содержание страницы № 3
IMPORTANT SAFETY INSTRUCTIONS When using an electrical appliance, ■ Remove plug from electrical outlet before basic precautions should be observed, cleaning or maintaining the appliance. including the following: ■ If the supply cord is damaged, it must be replaced by the manufacturer or its service REAd ALL agent in order to avoid a hazard. ■ Do not pick up toxic material (chlorine INSTRUCTIONS bleach, ammonia, drain cleaner, petrol, etc.). BEFORE USINg YOUR ■ Do not use for any purp
Краткое содержание страницы № 4
Product view Handle Air Flow Regulator Flex Hose Telescoping Extension Wand Easy Empty™ Dirt Cotainer Multi-Surface Hose Connector Floor Nozzle Brush Switch CAUTION: Do not plug in your vacuum until you are familiar with all instructions and Upholstery Tool Crevice Tool Dusting Brush operating procedures. 4 w w w. b i s s e l l . c a 1 - 8 0 0 - 2 6 3 - 2 5 3 5
Краткое содержание страницы № 5
Assembly 1. Connect the hose to the vacuum by inserting the hose connector into the WARNING: suction opening on the bottom front Plastic film can be of the vacuum. Push in until it clicks dangerous. To avoid danger into the locked position. of suffocation, keep away 2. Connect the telescoping extension from babies and children. wand to the handle end of the hose. 3. Connect the floor nozzle foot onto the telescoping extension wand. 1. 2. 4. Attach the tool holder onto the top porti
Краткое содержание страницы № 6
Operations Power cord The power cord is located at the rear of the vacuum. Gently pull out the power cord, watching for the yellow line. Stop pulling the power cord once the yellow line is visible. There is also a red line, which indicates the end of the usable Automatic Cord cord. Do not pull the power cord out Rewind Button beyond the red line. Automatic cord rewind Your vacuum is equipped with an automatic cord rewind. When cleaning is finished, press the power button OFF ( )an
Краткое содержание страницы № 7
Operations Power Power button Button Turn the power ON or OFF by pressing lightly downward on the power button ( ). Variable suction power control The variable suction power control is located on the back of the vacuum. Turn the control toward the larger dots for maximum suction. Turn the control toward the smaller dots to minimize suction for lightly soiled areas or delicate fabrics. Variable Suction Air flow regulator Control Open the air flow regulator by sliding the regulator
Краткое содержание страницы № 8
Operations Special tools Your BISSELL CleanView Multi cyclon- ic is not only a powerful Brush Up carpet and rug vacuum cleaner, 1. it’s also a versatile bare floor and above floor vacuum cleaner when you select one of the special tools. Floor nozzle: Use to vacuum carpets, rugs and bare floors. Swivel head turns to get into tight spaces and fits under cabinets. 2. Brush Down 1. To vacuum carpets and rugs, push the brush switch to the carpet position . This will pull the brushes up
Краткое содержание страницы № 9
Maintenance and care Emptying the dirt container Empty the dirt container as soon as WARNING: the dirt reached the “FULL” lines on To reduce the risk of electric the sides of the dirt container. shock, turn power switch OFF and 1. Unplug the vacuum from the electrical disconnect plug from electrical outlet. outlet before performing maintenance or troubleshooting checks. 2. Press the dirt container release button located on the back of the carry handle and lift up to remove. 3. Choo
Краткое содержание страницы № 10
Maintenance and care Cleaning the inner cyclone & screen Filters protect the motor from dirt and dust particles. Use only BISSELL replacement filters in your CleanView Multi Cyclonic 1. Unplug the vacuum from the electrical outlet. 3. 2. Remove the dirt container from the vacuum. 3. Remove the top portion of the dirt container by grasping the carry handle and turning counter clockwise and pulling up and out of the dirt container. 4. Remove the inner cyclone by grasping the bottom of the c
Краткое содержание страницы № 11
Maintenance and care Cleaning the pre-motor filter NOTICE: The pre-motor filter protects the motor This product is intended for household from dirt and dust particles. Use only use only and not for commercial or BISSELL replacement filters in your industrial use. Vacuuming of dust from products like plaster, concrete or ashes CleanView Multi Cyclonic. will damage the motor and void the 1. Turn the power OFF. Unplug the vacuum warranty. from the electrical outlet. 2. Remove the dirt
Краткое содержание страницы № 12
Maintenance and care Cleaning the Post-motor HEPA media filter The post-motor HEPA media filter assists in the filtration process to return clean air to the room. Use only BISSELL replacement filters in your CleanView Multi Cyclonic. 1. Turn the power OFF. Unplug the vacuum from the electrical outlet. 3. 2. The post-motor filter is located behind the door labeled “FILTER” on the rear of the vacuum. Open the door by pushing down on the tab of the door and pulling out to remove. 3. Remov
Краткое содержание страницы № 13
Troubleshooting WARNING: To reduce the risk of electric shock, turn power OFF and disconnect plug from electrical outlet before performing maintenance or troubleshooting. Vacuum cleaner won’t run Possible causes Remedies 1. Vacuum cleaner is no t plugged in 1. Check electrica l plug 2. Power button is no t pressed down 2. Press power button down 3. Therma l protector activated 3. Allow cleaner to coo l for 2 hours . See page 12. Vacuum cleaner won’t pic
Краткое содержание страницы № 14
BISSELL consumer services For information about repairs or replacement parts, or questions about your warranty, call: BISSELL Consumer Services 1-800-263-2535 Monday - Friday 8 a.m. — 10 p.m. ET Saturday 9 a.m. — 8 p.m. ET Or write: BISSELL Homecare, Inc. PO Box 3606 Grand Rapids MI 49501 ATTN: Consumer Services Or visit the BISSELL website - www.bissell.ca When contacting BISSELL, have model number of cleaner available. Please record your Model Number: ___________________ Please record y
Краткое содержание страницы № 15
Replacement parts - Item Part No. Part Name 1 203-1578 Hose 2 203-1579 Telescoping Extension Wand 3 203-1536 Multi-Surface Floor Nozzle 4 203-1583 Tool Holder 5 203-1581 Upholstery Tool 6 203-1580 Crevice Tool 7 203-1582 Dusting Brush 8 203-1575 Inner Cyclonic Assembly 9 203-1569 Pre-Motor Filter 10 203-1557 Post-Motor HEPA media Filter 1 2 3 4 5 6 7 8 9 10 15 w w w. b i s s e l l . c a 1 - 8 0 0 - 2 6 3 - 2 5 3 5
Краткое содержание страницы № 16
Warranty - BISSELL CleanView™ Multi Cyclonic Vacuum If you need additional instruction regarding this warranty or have questions regarding what it may cover, please contact BISSELL Consumer Services by E-mail, telephone, or regular mail as described below. Limited One Year Warranty Subject to the *EXCEPTIONS AND EXCLUSIONS identified below, upon receipt of the product, BISSELL Canada Corporation will repair or replace (with new or remanufactured components or products), at BISSELL’s option,