Краткое содержание страницы № 1
User's Manual
FT-902
FT-902S15/S35/S50
FT-905A
FT-906A20/906B20
10/100Base-TX to 100Base-FX
Web Smart Media Converter
Краткое содержание страницы № 2
Trademarks Copyright © PLANET Technology Corp. 2007. Contents subject to which revision without prior notice. PLANET is a registered trademark of PLANET Technology Corp. All other trademarks belong to their respective owners. Disclaimer PLANET Technology does not warrant that the hardware will work properly in all environments and applications, and makes no warranty and representation, either implied or expressed, with respect to the quality, performance, merchantability, or fitness fo
Краткое содержание страницы № 3
TABLE OF CONTENTS 1. INTRODUCTION............................................................................................................................................................. 1 1.1 PACKAGE CONTENTS .................................................................................................................................................... 1 1.2 HOW TO USE THIS MANUAL......................................................................................................
Краткое содержание страницы № 4
1. INTRODUCTION 1.1 Package Contents Check the contents of your package for following parts: ● Web Smart Media Converter x1 ● CD-ROM user's manual x1 ● Quick installation guide x1 ● External 5VDC/2A power adapter x 1 If any of these are missing or damaged, please contact your dealer immediately, if possible, retain the carton including the original packing material, and use them against to repack the product in case there is a need to return it to us for repair. FT-905A is with one
Краткое содержание страницы № 5
Supports Bandwidth Control (Kbps) for both Ingress and Egress Supports Broadcast Storm Control to optimize network bandwidth. Supports Ethernet Statistics on both TP and Fiber interface Look Back Test Function(LBT) , Link Loss Return(LLR) Firmware upgrade via HTTP protocol 5VDC power supply LED indicators for easy network diagnose Reset Button at the front panel for reset to factory default Choice of fiber-connector from ST, SC, MT-RJ/VF-45 and WDM, multi-mode / single-mode fi
Краткое содержание страницы № 6
2. INSTALLATION This section describes the functionalities of FT-90X’s components and guides how to install it on the desktop or shelf. Basic knowledge of networking is assumed. Please read this chapter completely before continuing. 2.1 Product Description The Web-Smart FT-90x Media Converters supports conversion between 10/100Base-TX and 100Base-FX network. There are SC/SFP connectors and single-mode/multi-mode media for your needs. Ethernet signal that allows two type segments connect
Краткое содержание страницы № 7
2.1.1 FT-90X Front Panel Figure 2-1, 2-2 & 2-3 shows a front panel of FT-90X. Figure 2-1 PLANET FT-902/FT-902S Front Panel Figure 2-2 PLANET FT-905A Front Panel Figure 2-3 PLANET FT-906A/B Front Panel -4-
Краткое содержание страницы № 8
2.1.2 LED Indicators ■ System LED Color Function PWR Green Lit: Power on. ■ 10/100Base-TX Port LED Color Function Lit: Indicate that the port is link up. Blink: Indicate that the converter is actively sending or receiving data over LNK/ACT Green that port. Off: Indicate that the port is link down or no data flow. Lit: Indicate that the connection made through the corresponding port is running in Full-Duplex mode. FDX Green Off: Indicate that the connection made through the c
Краткое содержание страницы № 9
2.1.3 FT-90X Rear Panel The rear panel of the converter indicates one DC jack, which accepts input power with 5V DC 2A. ■ FT-90x series Figure 2-6 Rear Panel of FT-90x Power Notice: 1. The device is a power-required device, it means, it will not work till it is powered. If your networks should active all the time, please consider using UPS (Uninterrupted Power Supply) for your device. It will prevent you from network data loss or network downtime. 2. In some area, installing a surge
Краткое содержание страницы № 10
2.2 Install the Converter This section describes how to install your FT-90X Web Smart Media Converter and make connections to the converter. Please read the following topics and perform the procedures in the order being presented. The hardware installation of PLANET FT-90X Web Smart Media Converter do not need software configuration. To install your FT-90X on a desktop or shelf, simply complete the following steps. 10/100Base-TX Cat. 5/5e TP Cable Network FT-90X 100Base-FX Fibe
Краткое содержание страницы № 11
Please refers to APPENDIX-A for detailed wiring information of the FT-90X. Note: To prevent from optic acceptor malfunction, check the both wires / transmitter before power on the converter. FT-905A Installation FT-905A is with high reliability and flexibility to extend the distance up to 2Km, 20Km, or longer. It depends on the 100Base-FX SFP transceiver modules. The SFP transceivers are hot-plug e and hot-swappable. You can plug-in and out the transceiver to/from any SFP port witho
Краткое содержание страницы № 12
2.2.2 Chassis Installation and Rack Mounting To install the media converter in a 10-inch or 19-inch with standard rack, follow the instructions described below. Step 1: Place your FT-90X on a hard flat surface, with the front panel positioned towards your front side. Step 2: Carefully slide in the module until it is fully and firmly fitted into the slot of the chassis. Figure 2-1: Insert a media converter into an available slot Step 3: Attach a rack-mount bracket to each side of the C
Краткое содержание страницы № 13
Figure 2-2 Mounting the Chassis in a Rack -10-
Краткое содержание страницы № 14
3. WEB MANAGEMENT This chapter describes how to manage the FT-90X. Topics include: - Overview - Management methods - Assigning an IP address to the FT-90X - Logging on to the FT-90X 3.1 Overview This chapter gives an overview of converter management. The FT-90X provides a simply WEB browser interface. Using this interface, you can perform various converter configuration and management activities, including: System Port Configuration Converter Configuration Converter Statu
Краткое содержание страницы № 15
3.2.2 Login the media converter Before you start configure the FT-90X, please note the FT-90X is configured through an Ethernet connection, make sure the manager PC must be set on same the IP subnet address. For example, the default IP address of the FT-90X is 192.168.0.100, then the manager PC should be set at 192.168.0.x (where x is a number between 2 and 254), and the default subnet mask is 255.255.255.0. Use Internet Explorer 6.0 or above Web browser. Enter IP address http://192.168.0
Краткое содержание страницы № 16
4. CONFIGURATION The FT-90X Web Smart Media Converter provide Web interface for Media converter smart function configuration and make the Media converter operate more effectively - They can be configured through the Web Browser. A network administrator can manage and monitor the FT-90x from the local LAN. This section indicates how to configure the media converter to enable its smart function. 4.1 Main Menu After a successful login, the main screen appears, the main screen displays the
Краткое содержание страницы № 17
4.2 System 4.2.1 System Information The System Information page provides information for the current device. System Info page helps a network manager to identify the versions and IP Address etc. The screen in Figure 4-2 appears. Figure 4-2 System Information screen The page includes the following fields: Specifies the device MAC address. • MAC Address • Software Version The current software version running on the device. • IP Address The current IP Address of the device. The IP Addr
Краткое содержание страницы № 18
4.2.2 IP Configuration The IP Configuration includes the IP Address, Subnet Mask and Gateway. The screen in Figure 4-3 appears. Figure 4-3 IP Configuration screen The page includes the following configurable data: IP Address - The IP address of the interface. The factory default value is 192.168.0.100 Subnet Mask - The IP subnet mask for the interface. The factory default value is 255.255.255.0 Gateway - The default gateway for the IP interface. The factory default value is 1
Краткое содержание страницы № 19
4.2.3 Password Setting This function provides administrator to secure Web login. The screen in Figure 4-4 appears. Figure 4-4 Password Setting screen The page includes the following configurable data: Login Name Displays the user name. Old Password Enter the old password is required before entering the new password New Password Specifies the new password. The password is not displayed. As it entered an “ ” corresponding to each character is displayed in the field. (The maximum
Краткое содержание страницы № 20
4.3 Port Configuration This function allows displaying each port’s status. The Link Status in the screen displays the current connection speed and duplex mode; else this function will show down when the port is disconnected. Press the “Refresh” button to renew the screen. The screen in Figure 4-5 appears. Figure 4-5 Port Configuration screen The page includes the following configurable data: • Port Indicate the Copper port and Fiber port • Link Displays the current connection spe