Краткое содержание страницы № 1
Section 530
Digital Business System
ISDN
Reference
Manual
for CPC-EX Version 2.3
Doc. No. 504X00301C
Revised April 2000
Краткое содержание страницы № 2
The contents of this document are subject to change without notice and do not constitute a commitment on the part of Panasonic Telecommunication Systems Company (PTSC). Every effort has been made to ensure the accuracy of this document. However, due to ongoing product improvements and revisions, Panasonic cannot guarantee the accuracy of printed material after the date of publication nor can it accept responsibility for errors or omissions. Panasonic will update and revise this document as
Краткое содержание страницы № 3
Contents About This Manual Overview............................................................................................................................ vii Related Documents ............................................................................................................ vii Chapter 1. Introduction to the ISDN Interface Overview................................................................................................................................. 1-3 Description of th
Краткое содержание страницы № 4
Chapter 4. Programming Reference ISDN System Settings ............................................................................................................ 4-3 System Size....................................................................................................................... 4-3 T1/ISDN............................................................................................................................ 4-3 Clock Settings .............................................
Краткое содержание страницы № 5
List of Figures Figure 2-1 CSU installation .......................................................................................... 2-13 Figure 2-2 SCC-B Switch 4 .......................................................................................... 2-15 Figure 2-3 Connector 4 (CN4) strapping, Sync Unit .................................................... 2-15 Figure 2-4 Sync Unit installation .................................................................................. 2-16 Figure 2
Краткое содержание страницы № 6
List of Tables Table 1-1 Guidelines for ordering ISDN services ......................................................... 1-4 Table 4-1 ISDN alarm definitions ............................................................................... 4-17 Table 5-1 ISDN Hardware requirements for single-cabinet systems ............................ 1-8 Table 5-2 ISDN Hardware requirements for double-cabinet systems ......................... 1-8 Table 5-3 CSU equipment required for ISDN .......................
Краткое содержание страницы № 7
About This Manual Overview This manual provides an overview of the DBS ISDN Interface, along with installation and programming instructions when used with CPC-EX Version 2.2. Appendix A provides updates for CPC-EX version 2.3 as well. The following table summarizes each chapter contained in this manual. Chapter Title Purpose Introduction to the Provides an overview of the DBS ISDN Interface, plus 1 ISDN Interface information on pre-installation requirements. Installation Provides step-by-step
Краткое содержание страницы № 8
viii DBS-EX23-530 Revised April 2000
Краткое содержание страницы № 9
Chapter 1. Introduction to the ISDN Interface This chapter provides an overview of the ISDN Interface. It also describes pre-installation requirements for the ISDN. The following table summarizes the topics contained in this chapter. Topic Page Overview 1-3 Description of the ISDN Interface 1-3 Framing Options 1-3 Pre-Installation Requirements 1-4 Ordering ISDN 1-4 What You Must Purchase 1-8 Revised April 2000 DBS-EX23-530 1-1
Краткое содержание страницы № 10
1-2 DBS-EX23-530 Revised April 2000
Краткое содержание страницы № 11
Introduction to the ISDN Interface Overview Overview Description of the ISDN Interface The ISDN Interface is a Primary Rate Interface (PRI) digital trunk card that provides 23 voice channels (“B” channels) and a control channel (“D” channel) over a four-wire circuit. ISDN lines can be leased from local exchange carriers and long-distance carriers. Note: The current version of the ISDN supports voice communications only. Data can be transmitted only if it reaches the ISDN in analog form. Ex
Краткое содержание страницы № 12
Pre-Installation Requirements Introduction to the ISDN Interface Pre-Installation Requirements Use the following guidelines to prepare your site for ISDN installation. Ordering ISDN The ISDN PRI provides a flexible method of providing access to the PSTN (Public Switched Telephone Network). Because of the numerous ways that an ISDN span can be configured by the CO, it is essential that the DBS configuration and the provisioning of the CO be compatible. The following tables are provided to
Краткое содержание страницы № 13
Introduction to the ISDN Interface Pre-Installation Requirements 9 Long distance Carrier (IntraLATA) This identifies the carrier who will provide (LPIC) access for connections, which are not local but are still within the local LATA. 10 Request date of installation 11 Facility type ISDN PRI 12 Facility quantity 1 or 2 spans NOTE THAT THE FOLLOWING ITEMS MUST BE PROVIDED ON A PER SPAN BASIS 13 Signaling code DS-1 (1.544 Mbps) 14 Line coding B8ZS (Binary 8 Zero Substitution) 15 Framing Format ES
Краткое содержание страницы № 14
Pre-Installation Requirements Introduction to the ISDN Interface Copy the following tables for each site and span that is to be installed. Complete all information and use for future reference. Note that certain parameters are shown with default values. # Information Needed from CO Site Information 1 Manufacture of CO and software load 2 Is local dialing 7 digits, 10 digits or a combination. 3 For long distance dialing does the CO want to see a leading “1” or not. 4 For international diali
Краткое содержание страницы № 15
Introduction to the ISDN Interface Pre-Installation Requirements Span Item Master Cabinet Span Slave Cabinet Span 13 Signaling code DS-1 DS-1 14 Line coding B8ZS B8ZS 15 Framing Format ESF ESF 16 Bearer configuration Voice or Voice/Data Voice or Voice/Data 17 Quantity of B (bearer) channels 18 Call type Two-way Two-way 19 Quantity of phone numbers 20 Number of incoming digits to 4 digits 4 digits CPE (Customer Premise Equipment –DBS) 21 ISDN PRI Protocol 22 Glare Resolution CPE yield to CO C
Краткое содержание страницы № 16
Pre-Installation Requirements Introduction to the ISDN Interface What You Must Purchase The following items must be purchased to install ISDN. DBS Equipment If you are installing the ISDN in a single-cabinet system, order the equipment included in Table 1-1. For two-cabinet systems, see Table 1-2. Table 1-1. ISDN Hardware requirements for single-cabinet systems CPC-EX SCC-B ISDN Trunk Card MDF Card Sync Unit (VB-43415) (VB-43421) (VB-43571) (VB-43562) (VB-43563) 1 1 1 11 (See Note 1.) (See Not
Краткое содержание страницы № 17
Introduction to the ISDN Interface Pre-Installation Requirements CSU Equipment The installer must provide a Channel Service Unit (CSU) plus CSU cabling. The CSU equipment must meet the specifications contained in Table 1-3. See page 2-12 for instructions on installing the CSU. Table 1-3. CSU equipment required for ISDN Item Specifications Vendors CSU The Channel Service Unit (CSU) must The following CSUs have been used suc- comply with FCC Part 15 and Part 68. The cessfully with the DBS ISDN.
Краткое содержание страницы № 18
Pre-Installation Requirements Introduction to the ISDN Interface 1-10 DBS-EX23-530 April 2000
Краткое содержание страницы № 19
Chapter 2. Installation This section describes guidelines and procedures for installing the ISDN Interface. Once the ISDN Interface is installed, refer to Chapter 3 - “Quick Start Programming” or Chapter 4 - “Programming Reference” for programming instructions. This chapter covers the following topics. Topic Page Guidelines 2-3 Hardware Requirements 2-3 Maximums 2-3 Trunk Assignments for Single-Cabinet Systems 2-5 Trunk Assignments for Double-Cabinet Systems 2-6 Installation Procedures 2-12 I
Краткое содержание страницы № 20
2-2 DBS-EX22-530 Revised April 2000