Краткое содержание страницы № 1
Title Page
™
7F06-02 FDDI SmartSwitch
Interface Module
User’s Guide
903 9031672-02
Краткое содержание страницы № 2
Краткое содержание страницы № 3
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FO
Краткое содержание страницы № 4
Notice DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. VCCI NOTICE
Краткое содержание страницы № 5
Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This
Краткое содержание страницы № 6
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Di
Краткое содержание страницы № 7
CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual....................................................................... 1-1 1.2 The 7F06-02 Module ................................................................... 1-1 1.2.1 Cable Type and FPIMs ................................................... 1-2 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch.................................................................... 1-3 1.3 Feature
Краткое содержание страницы № 8
Contents CHAPTER 5 TECHNICAL SPECIFICATIONS 5.1 Standards.....................................................................................5-1 5.2 EMI...............................................................................................5-1 5.3 EMC .............................................................................................5-1 5.4 Network Interfaces .......................................................................5-1 5.5 Safety...............................
Краткое содержание страницы № 9
CHAPTER 1 INTRODUCTION Welcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User Guide. This guide is a simple reference for installing and using the 7F06-02 Module. Before installing this module, you should carefully read through this manual to gain a full understanding of its capabilities. The 7F06-02 Module is a two-port FDDI module. This module connects to a network and the 7X00 SmartSwitch™ Control Module in the 7C03, 7C04 or 7C04-R MMAC Smart
Краткое содержание страницы № 10
Chapter 1: Introduction 1.2.1 Cable Type and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 SmartSwitch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs. There are two FPIMs for each channel. These FPIMs allow the use of single mode or multimode fiber cable with MIC or SC type connectors and twisted pair cable, either shielded or unshielded. 7F06-02 SP A F D SN D P A S B I 1 B A F D P A D B S I 2 B Figur
Краткое содержание страницы № 11
Chapter 1: Introduction 1.2.2 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch and the 7C04-R Workgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMAC SmartSwitch, the 7C04 Workgroup SmartSwitch or the 7C04-R Workgroup SmartSwitch. The modular design of the 7C03 MMAC SmartSwitch allows other modules that support Ethernet, Fast Ethernet, ATM, FDDI, or Token Ring to be used with the 7F06-02 Module. These modules provide the capability to share d
Краткое содержание страницы № 12
Chapter 1: Introduction 1.3.3 Connectivity The 7F06-02 Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection provides power to the 7F06-02 Module and a channel for communication with the 7X00 SmartSwitch Control Module. The two front panel FPIMs provide FDDI connections, allowing the use of single mode or multimode fiber cable with MIC or SC type connectors. 1.4 RELATED MANUALS The following Cabletron Systems manuals supplement
Краткое содержание страницы № 13
Chapter 1: Introduction 1.5 GETTING HELP If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center: Phone (603) 332-9400 Internet mail support@ctron.com FTP ctron.com (134.141.197.25) Login anonymous Password your email address BBS (603) 335-3358 Modem setting 8N1: 8 data bits, No parity, 1 stop bit For additional information about Cabletron Systems or our
Краткое содержание страницы № 14
Chapter 1: Introduction 1-6 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
Краткое содержание страницы № 15
CHAPTER 2 NETWORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, review the network requirements outlined in this chapter. All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module. Failure to do so may result in unsatisfactory network performance. 2.1 FPIM MODULE SPECIFICATIONS This module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs are user-installable. Refe
Краткое содержание страницы № 16
Chapter 2: Network Requirements Table 2-2 Transmitter Power Parameters Worst Worst Typical Parameter Typical Value Case Case Budget Budget 50/125 m m -13.0 dBm -15.0 dBm 13.0 dB 17.5 dB fiber 62.5/125 -10.0 dBm -12.0 dBm 16.0 dB 20.5 dB m m fiber 100/140 m m -7.0 dBm -9.0 dBm 19.0 dB 23.5 dB fiber -10 Error Rate Better than 10 The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD. 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an R
Краткое содержание страницы № 17
Chapter 2: Network Requirements 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector. The specifications for both devices are listed in Table 2-4. Table 2-4 FPIM-05 and FPIM-07 Specifications Parameter Typical Minimum Maximum Transmitter Peak Wave Length 1300 nm 1270 nm 1330 nm Spectral Width 60 nm - 100 nm Rise Time 3.0 nsec 2.7 nsec 5.0 nsec Fall Time 2.5 nsec 2.2 nse
Краткое содержание страницы № 18
Chapter 2: Network Requirements 2-4 7F06-02 FDDI SmartSwitch Interface Module User’s Guide
Краткое содержание страницы № 19
CHAPTER 3 INSTALLATION/REMOVAL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMAC SmartSwitch • 7C04 Workgroup SmartSwitch • 7C04-R Workgroup SmartSwitch Also included in the chapter are instructions for installing the front panel FPIMs. 3.1 UNPACKING THE 7F06-02 MODULE Unpack the 7F06-02 Module by using the following steps: Before unpacking the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or Smart
Краткое содержание страницы № 20
Chapter 3: Installation/Removal 3.2 INSTALLING FPIMS Before installing the 7F06-02 module, attach the antistatic wrist strap included with the SmartSwitch or SmartSwitch module by following the instructions printed on the package. The 7F06-02 module is shipped without FPIMs. To install an FPIM, follow the procedure below: 1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the procedure in Section 3.3. 2. Remove the blank front cover over the FPI