Краткое содержание страницы № 5
Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This
Краткое содержание страницы № 6
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir
Краткое содержание страницы № 7
CONTENTS CHAPTER 1 INTRODUCTION 1.1 ABOUT THIS MANUAL ........................................................................1-1 1.2 GETTING HELP.......................................................................................1-2 1.4 RELATED DOCUMENTATION ...........................................................1-4 1.5 OVERVIEW...............................................................................................1-4 1.5.1 SmartSTACK 10 ELS10-26 Architecture.......
Краткое содержание страницы № 8
Contents 3.10 DISPLAYING MONITORING STATUS...........................................3-12 3.11 DEFINING AND DELETING WORKGROUPS ..............................3-14 3.12 ASSIGNING A COMMUNITY NAME.............................................3-16 3.13 CONFIGURING BROADCAST/MULTICAST STORM PROTECTION ......................................................................................3-17 3.14 MODIFYING MIB VARIABLES.........................................................3-18 3.15 SYST
Краткое содержание страницы № 9
Contents CHAPTER 5 ELS10-26 DIAGNOSTICS AND TROUBLESHOOTING 5.1 POWER-UP DIAGNOSTICS ..................................................................5-1 5.1.1 Power-up LED Sequence ..............................................................5-1 5.1.2 Specific Power-up Tests ................................................................5-2 5.1.3 Software Checksum Comparison................................................5-2 5.1.4 Power-up Diagnostics Results ..................
Краткое содержание страницы № 10
Contents viii
Краткое содержание страницы № 11
CHAPTER 1 INTRODUCTION 1.1 ABOUT THIS MANUAL This manual is for system administrators responsible for configuring, monitoring, and maintaining the SmartSTACK 10 ELS10-26TX. You should have a familiarity with networking concepts and principles. In addition, a basic understanding of SNMP is helpful. Some SmartSTACK 10 ELS10-26 configurations can only be done using an SNMP-based Network Management System (NMS). Where applicable, this manual provides instructions for using the
Краткое содержание страницы № 12
Introduction • Chapter 5, ELS10-26 Diagnostics and Troubleshooting, describes the SmartSTACK 10 ELS10-26 diagnostics and provides information on troubleshooting common problems. • Appendix A, Technical Specifications, provides the SmartSTACK 10 ELS10-26 specifications and basic cabling pin assignments. • Appendix B, Glossary, provides a glossary of terms both specific to the SmartSTACK 10 ELS10-26 and common to the networking field. 1.2 GETTING HELP If you need additional s
Краткое содержание страницы № 13
Introduction Before calling Cabletron Systems Global Call Center, have the following information ready: • Your Cabletron Systems contract number • A description of the failure • A description of any action(s) already taken to resolve the problem (e.g., changing mode switches, rebooting the unit, etc.) • The serial and revision numbers of all Cabletron Systems products in the network • A description of your network environment (layout, cable type, etc.) • Network load and fram
Краткое содержание страницы № 14
Introduction and an IP address to execute the ipaddr command: ELS10-26 >ipaddr 6 192.138.217.40 Field value options appear in bold typeface. The following conventions are also used in this document: Note: Calls the reader’s attention to any item of information that may be of special importance. Tip: Conveys helpful hints concerning procedures or actions. Caution: Contains information essential to avoid damage to the equipment. Warning: War
Краткое содержание страницы № 15
Introduction 1.5 OVERVIEW The SmartSTACK 10 ELS10-26TX is an intelligent Ethernet-to- Ethernet switch that is configured with 25 IEEE 802.3 10BASE-T Full Duplex Ethernet ports, one fixed 100BASE-TX copper connection, one port supporting either a copper or fiber 100 Mbps FEPIM (Fast Ethernet Port Interface Module), and one fixed RJ45 for port monitoring of the 10 Mbps ports. It also includes an RS232C port for out-of-band management. Figure 1-1 shows the front panel for the SmartSTACK 10
Краткое содержание страницы № 16
Introduction • Operates in either Half Duplex or Full Duplex modes on all ports. • Implements the Spanning Tree protocol (802.1d). • Configured with factory-set defaults for immediate plug-and- play capability (IP address is not configured at factory). In addition, the SmartSTACK 10 ELS10-26 offers the following features that can help you manage and maintain your network: • RMON support. • Configuration and management using the Simple Network Management Protocol (SNMP) with either
Краткое содержание страницы № 17
Introduction new devices to the network, change device addresses, and remove devices from the network without having to reconfigure the SmartSTACK 10 ELS10-26. The Open System Interconnection (OSI) Reference Model, developed by the International Standards Organization (ISO), identifies the levels of functionality inherent in each of its seven layers. The SmartSTACK 10 ELS10-26 operates at the Media Access Control (MAC) sub-layer of the Data Link layer. Figure 1-2 shows the OSI Refere
Краткое содержание страницы № 18
Introduction network and when it is granted permission to transmit. In addition, full store and forward switching ensures data integrity, thus preventing network error conditions from being generated throughout the network. Discarding Local Traffic The SmartSTACK 10 ELS10-26 checks all incoming packets for their destination address against the Bridge Address Table. If a packet’s destination address is not on the same network segment as the originating packet, the SmartSTACK 10 ELS1
Краткое содержание страницы № 19
Introduction By forwarding only packets addressed to devices on other network segments, the SmartSTACK 10 ELS10-26 reduces unnecessary traffic and thereby enhances the overall performance of the network. Note: If the packet address is not found in the Bridge Address Table, it will be forwarded (flooded) to all network segments. Spanning Tree Algorithm The SmartSTACK 10 ELS10-26 supports the IEEE 802.1d Spanning Tree algorithm. The Spanning Tree algorithm converts multiple LANs int
Краткое содержание страницы № 20
Introduction If a packet’s address is not already stored in the Bridge Address Table, the SmartSTACK 10 ELS10-26 adds the learned address, associated segment number, and a timer value indicating the age of the observation. Consequently, the SmartSTACK 10 ELS10-26 knows the address and associated segment number the next time it sees that address. By using the information stored in the Bridge Address Table, the SmartSTACK 10 ELS10-26 is able to quickly forward each packet to the correct
Краткое содержание страницы № 1
SmartSTACK 10
ELS10-26 USER GUIDE
ELS10-26TX
PORT STATUS MODE
TX ACT FDX MON
1 3 5 7 9 11 13 15 17 19 21 23 25 26
2 4 6 8 10 12 14 16 18 20 22 24 MON 27
RX COL 100 USR
FEPIM
10BASE-T/
100BASE-TX
STATUS
PWR
CPU
RESET 27
COM 2X 4X 6X 8X 10X 12X 14X 16X 18X 20X 22X 24X MONX 26X
9032243-01
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATUS
LINK
STATU
Краткое содержание страницы № 2
Краткое содержание страницы № 3
Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR
Краткое содержание страницы № 4
Notice DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. VCCI NOTICE