Краткое содержание страницы № 1
Enterprise Networking Solution
Installation Guide
L2 Managed Switch
TL-SG3210/TL-SG3216/TL-SG3424/TL-SG3424P
Краткое содержание страницы № 2
COPYRIGHT & TRADEMARKS Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2013 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved. htt
Краткое содержание страницы № 3
Related Document The User Guide and CLI Reference Guide of the product are provided on the resource CD. To obtain the latest product information, please visit the official website: http://www.tp-link.com About this Installation Guide This Installation Guide describes the hardware characteristics, installation methods and the points that should be attended to during installation. This Installation Guide is structured as follows: Chapter 1 Introduction. This chapter describes the external co
Краткое содержание страницы № 4
Contents Chapter 1 Introduction ———————————— 01 1.1 Product Overview .........................................01 1.2 Appearance .................................................01 Chapter 2 Installation ————————————— 06 2.1 Package Contents .........................................06 2.2 Safety Precautions ........................................06 2.3 Installation Tools ..........................................08 2.4 Product Installation ......................................08 Chapter 3 Li
Краткое содержание страницы № 5
L2 Managed Switch ChaCter C Introduction C1C Product Overview TP-LINK JetStream L2 Managed Switch, designed for workgroups and departments, provides wire-speed performance and abundant layer 2 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. ACL, 802.1x and Dynamic ARP Inspection provide robust
Краткое содержание страницы № 6
L2 Managed Switch LEDs LED Status Indication On The switch is powered on. PWR Off The switch is powered off or power supply is abnormal. Flashing Power supply is abnormal. Flashing The switch works properly. SYS On/Off The switch works improperly. On A device is linked to the corresponding port. Flashing Data is being transmitted or received. Green The linked device is running at 1000Mbps. 10/100/1000M Yellow The linked device is running at 10/100Mbps. Off No device is connected to the correspo
Краткое содержание страницы № 7
L2 Managed Switch LED Status Indication On A 1000Mbps device is connected to the corresponding port. 1000Mbps A 10/100Mbps device or no device is connected to the Off corresponding port. A device is connected to the corresponding port, but no On activity. Link/Act Flashing Data is being transmitted or received. Off No device is connected to the corresponding port. The front panel of TL-SG3424P is shown as the following figure. LEDs Console Port 10/100/1000Mbps RJ45 Port SFP Port Figure 1-4
Краткое содержание страницы № 8
L2 Managed Switch LED Status Indication On The remaining PoE power ≤7W. The remaining PoE power keeps ≤7W after this LED is PoE Max Flashing on for 2 minutes. Off The remaining PoE power ≥7W. On The port is supplying power normally. Green The supply power exceeds the correponding port's Flashing maximum power. 10/100/ On Overload or short circuit is detected. 1000 Mbps Yellow Flashing Power-on self-test has failed. Off No PoE power supply is provided on the port. Note: TL-SG3216/TL-SG3424/TL
Краткое содержание страницы № 9
L2 Managed Switch Grounding Terminal Power Socket Figure 1-5 Rear Panel of TL-SG3210 The rear panel of TL-SG3216/TL-SG3424/TL-SG3424P is shown as the following figure. Grounding Terminal Power Socket Figure 1-6 Rear Panel of TL-SG3216/TL-SG3424/TL-SG3424P Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth1 cable of AC cord or with Ground Cable. For detailed information, please refer to Chapter 3 Li
Краткое содержание страницы № 10
L2 Managed Switch ChaCter 1 Installation 11CPackage Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. One Switch One Power Cord, One Console This Installation Guide Cable and one Ground Cable Two mounting brackets and One Resource CD the fittings 111Safety Precautions To avoid any device damage and bodily injury caused by improper use, please observe the following rules. ■ Safety Precaution
Краткое содержание страницы № 11
L2 Managed Switch Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions. Too high temperature may accelerate aging of the insulation materials and can thus significantly shorten the service life of the device. For normal temperature and humidity of the device, please check the following table. Environment Temperature Humidity Operating 0℃ ~ 40℃ 10% ~ 90%RH Non-con
Краткое содержание страницы № 12
L2 Managed Switch ■ E nsure the rack and device are well earthed. ■ Ma ke sure the power socket has a good contact with the ground. ■ K eep a reasonable cabling system and avoid induced lightning. ■ Use the signal SPD (Surge Protective Device1 when wiring outdoor. Note: For detailed lightning protection measures, please refer to Chapter 3 Lightning Protection. Installation Site When installing the device on a rack or a flat workbench, please note the following items: ■ T he rack or work
Краткое содержание страницы № 13
L2 Managed Switch Feet Bottom of the Device Notch Figure 2-1 Desktop Installation ■ Rack Installation To install the device in an EIA standard-sized, 19-inch rack, follow the instructions described below: 1. Check the grounding and stability of the rack. 2. Secure the supplied rack-mounting brackets to each side of the device with supplied screws, as illustrated in the following figure. Rack- mounting Bracket Screw Figure 2-2 Bracket Installation 3. After the brackets are attached to the
Краткое содержание страницы № 14
L2 Managed Switch ChaCter 2 Lightning Protection 21CCabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices. Note: It’s not recommended using Ethernet cables outdoors. When cabling outdoors, please use a signal lightning arrester. ■ Requirements for Cabling Outdoors ■ Aerial cabling without safegua
Краткое содержание страницы № 15
L2 Managed Switch ■ Requirements for the distance between Ethernet cable and other pipelines are shown in the table. Ethernet Cable Other Pipelines Min Parallel Net Length Min Parallel-overlapping Net Height L (mm1 H (mm1 Down-conductor 1000 300 PE 50 20 Service pipe 150 20 Compressed air pipe 150 20 Thermal pipe (not wrapped1 500 500 Thermal pipe (wrapped1 300 300 Gas pipe 300 20 The two diagrams below demonstrate parallel net length and parallel-overlapping net height. Note: The above min
Краткое содержание страницы № 16
L2 Managed Switch 211Connect to Ground Connecting the device to ground is to quickly release the lightning over-voltage and over-current of the device, which is also a necessary measure to protect the body from electric shock. In different environments, the device may be grounded differently. The following will instruct you to connect the device to the ground in two ways, connecting to the grounding bar or connecting to the ground via the power cord. Please connect the device to ground in
Краткое содержание страницы № 17
L2 Managed Switch Note: ■ The figure is to illustrate the application and principle. The power cord you get from the package and the socket in your situation will comply with the regulation in your country, so they may differ from the figure above. ■ If you intend to connect the device to the ground via the PE (Protecting Earth1 cable of AC power cord, please make sure the PE (Protecting Earth1 cable in the electrical outlet is well grounded in advance. 212Equi Cotential Bonding Equipoten
Краткое содержание страницы № 18
L2 Managed Switch 212Use Lightning Arrester Power lightning arrester and signal lightning arrester are used for lighting protection. Power lightning arrester is used for limiting the voltage surge due to a lightning. If an outdoor AC power cord should be directly connected to the device, please use a power lightning arrester. Note: Power lightning arrester is not provided with our product. If needed, please self purchase it. Signal lightning arrester is used to protect RJ45 ports of the dev
Краткое содержание страницы № 19
L2 Managed Switch ChaCter 2 Connection 21CEthernet Port Connect the Ethernet ports of the switch to the network devices by RJ45 cable as the following figure shown. RJ45 Port RJ45 Cable Figure 4-1 Connecting the RJ45 Port 211SFP Port Connect the SFP port to a SFP module. For TL-SG3216/TL-SG3424/TL-SG3424P, if an SFP transceiver (purchased separately1 is installed in a slot and has a valid link on the port, the associated RJ45 port will be disabled and cannot be used. SFP Port SFP Module
Краткое содержание страницы № 20
L2 Managed Switch 212Console Port CLI (Command Line Interface1 enables you to manage the switch, thus you can load the CLI after connecting the PCs or Terminals to the console port on the switch via the provided cable. Connect the console port of the device with your computer by the console cable as the following figure shown. Figure 4-3 Connecting the Console Port You can also manage the device through the console port, for details please refer to the CLI Reference Guide on the resource