This document describes how to install and to set up the
PROMENTUM™
Promentum™ ATCA-2210 switch and control module
(SCM).
SWITCH AND CONTROL MODULE
INSTALLATION GUIDE
Obey ESD precautions
WARNING! Obey the electrostatic discharge (ESD)
ATCA-2210
procedures described at www.radisys.com when you install
the product.
Electrostatic discharge can cause permanent damage to
static-sensitive components in this product. Important ESD
procedures include:
Keep the product in its ESD shielding ba
Краткое содержание страницы № 2
Installation Guide Configuration recommendations Standard SCM configurations come without SFP or XFP transceivers installed. To protect the internal components of the SCM, transceivers or filler plugs must be installed in all empty sockets: The Base Ethernet configuration supports up to four SFP transceivers and one XFP transceiver, with filler plugs installed in unused sockets. The Fabric Ethernet configuration supports up to four XFP transceivers, with filler plugs installed in unused soc
Краткое содержание страницы № 3
Install SFPs or XFPs on the SCM Filler plug installation If XFP or SFP transceivers are removed, install either replacement transceivers or filler plugs in the sockets to protect the internal components of the SCM. Additional filler plugs can be ordered from the applicable manufacturer; for a list of tested and qualified transceivers and filler plugs, see the Support section of the RadiSys Web site at www.radisys.com. Install fillers plugs using the insertion guidelines described below: XFP
Краткое содержание страницы № 4
Installation Guide SCM installation checklist The following table describes the possible installation scenarios for the SCM, the appropriate tasks to complete for the scenarios, and the order to complete the tasks: SCM is being..... Configuration Tasks to complete and order to complete them Installed in a RadiSys shelf Standard configuration. 1. Install the SCM in the shelf on page 5 ____ 2. Connect to the SCM on page 6 ____ 3. Verify switch operation on page 7 ____ 4. Verify shelf management
Краткое содержание страницы № 5
Install the SCM in the shelf Install the SCM in the shelf 1. Follow ESD precautions and make sure you are Open position adequately grounded before handling the transceivers and the SCM. a) push inner latch 2. Remove the SCM from its antistatic bag. in all the way 3. Open both ejector latches outward. WARNING! Never force open an ejector latch. Press the inner latch all the way in before you pull out the handle. If the latch does not open fully, close the latch and try again, making sur
Краткое содержание страницы № 6
COM-E COM-E LMP COM-E LMP USB SER SER ETH ETH XFP 1/1 OOS PWR ACT LINK PORT LINK Installation Guide Connect to the SCM The SCM can be accessed by an external computer through the serial and the Ethernet maintenance ports. Use the serial port to perform diagnostic and verification procedures or to enable or disable the Shelf Manager. Use the Ethernet maintenance port to connect the SCM to the network and to perform configuration procedures. Note: If you have two SCMs installed, connect to each
Краткое содержание страницы № 7
Verify switch operation Verify switch operation Use these steps to view port status and to enable ports on the Base Ethernet and the Fabric Ethernet switches. View port status 1. Verify you are at this prompt. ATCA-2210# If you are not at the appropriate prompt, see Connect to the SCM on page 6 for instructions on how to get there. 2. Enter the applicable command for the switch you are verifying. Switch Command to enter Resulting prompt Base Ethernet base-ethernet ATCA-2210-Base# Fabric Ether
Краткое содержание страницы № 8
Installation Guide Enable all ports 1. Verify you are at the applicable switch prompt. Switch Prompt Base Ethernet ATCA-2210-Base# Fabric Ethernet ATCA-2210-Fabric# If you are not at the appropriate prompt, see View port status for instructions on how to get there. 2. Enter this series of commands to enable all ports. A. configure B. no shutdown all C. spanning-tree port mode all D. spanning-tree E. exit F. telnetcon timeout 60 G. copy system:running-config nvram:startup-config This op
Краткое содержание страницы № 9
Verify switch operation B. Enter the specific port (interface) number to enable. The s variable represents the specified slot. The p variable represents an individual port within the group of ports for the specified slot. interface Where s and p have the following values: Base Ethernet switch interfaces ATCA-6000 backplane slots s=0 p=1-6, 9-14 ATCA-6006 backplane slots s=0 p=3-6 ATCA-6014 backplane slots s=0 p=1-6, 9-14 ATCA-6016 backplane slots s=0 p=1-7, 10-16 Front panel optical
Краткое содержание страницы № 10
Installation Guide 3. Enter the exit command again, to log off the SCM. 4. If you have two SCMs installed, repeat these steps on the other SCM. Verify shelf management operation These steps confirm that shelf management is operating when the SCM is installed in a RadiSys shelf. If the SCM is installed in a non-RadiSys shelf, shelf management is not available. 1. Verify that you are at this prompt. ATCA-2210# If you are not at the appropriate prompt, see Connect to the SCM on page 6 for instr
Краткое содержание страницы № 11
Disable the Shelf Manager on the SCM 6. To determine the version of SCM’s on-board Shelf Manager, enter: rsys_debug -h 7. After determining the version, enter the appropriate command. For version Enter this command Result 0.96 or below rsys_debug Takes you directly to IPMI serial interface. 0.97 or above rsys_debug -i 127.1 Enables LAN access. 8. Once the software tool has completed its initialization, the host address is displayed. Make a note of this address for an upcoming step. Typically
Краткое содержание страницы № 12
Installation Guide Enable the Shelf Manager on the SCM If you plan to remove an SCM from a non-RadiSys shelf and reinstall it in a RadiSys shelf, enable the on-board Shelf Manager before removing the SCM. Important: If the SCM is removed from the non-RadiSys shelf without having its on-board Shelf Manager enabled, you will need to install the SCM in a shelf (RadiSys or non-RadiSys) that already has an active Shelf Manager running. 1. Connect the included serial port cable by plugging one en
Краткое содержание страницы № 13
Rear I/O connectivity 13. The following text displays: Get SCM ShMgr Mode - Enter address (in hex): Enter the same host address you entered for step 10. If the on-board Shelf Manager is disabled, this message displays: SCM ShMgr Mode: Enabled 14. Enter q to exit the rsys_debug mode. 15. Remove the SCM and reinstall it in a RadiSys shelf. For removal instructions, see the Switch and Control Module Reference. For installation instructions, see Install the SCM in the shelf on page 5 of this
Краткое содержание страницы № 14
Installation Guide Where to get more product information Please visit the RadiSys Web site at www.radisys.com for product information and other resources. Downloads (manuals, release notes, software, etc.) are available via the Technical Support Library product links at www.radisys.com/support or the product pages at www.radisys.com/products. 14