Краткое содержание страницы № 1
Industrial 3-Port Fast Ethernet
Media Converter Switches
KSD-103-A series
KSD-103-B series
Installation Guide
DOC.081111
1/20
Краткое содержание страницы № 2
(C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used to make any directive work (such as translation or transformation) without permission from KTI Networks Inc. KTI Networks Inc. reserves the right to revise this documentation and to make changes in content from time to time without obligation on the part of KTI Networks Inc. to provide notification of such revision or change. For more information, contact:
Краткое содержание страницы № 3
The information contained in this document is subject to change without prior notice. Copyright (C) All Rights Reserved. TRADEMARKS Ethernet is a registered trademark of Xerox Corp. FCC NOTICE This device complies with Class B Part 15 the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received including the interference that may cause. CE NOTICE Marking by the sy
Краткое содержание страницы № 4
Table of Contents 1. Introduction ................................................................................................................................5 1.1 Features.................................................................................................................6 1.2 Product Panels ......................................................................................................6 1.3 Specifications...............................................................
Краткое содержание страницы № 5
1. Introduction The industrial rated KSD-103 Fast Ethernet switch series supports three switching-base segment communications and benefit the following applications and make fiber deployment easier : Copper to fiber bridging converter Multimode fiber to single mode fiber bridging converter Fiber cable extender Cascaded fiber networking Depending on the types of the network ports, two different model series are defined as follows: Model Copper Port (RJ-45) Fiber Port KSD-103
Краткое содержание страницы № 6
High and wide operating Temperature Power input interface: Industrial screw terminal block and DC power jack for external commercial power adapter as option Screw panel and DIN rail mounting support for industrial enclosure Industrial-rated Emission and Immunity performance 1.1 Features Provide 3 switching-base network segments Auto MDI/MDI-X crossover function on the TP copper port Support IEEE 802.3x flow control for full-duplex operation Support Back-pressure flow control f
Краткое содержание страницы № 7
KSD-103-B 1.3 Specifications Copper Ports Compliance IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX Connectors Shielded RJ-45 jacks Pin assignments Auto MDI/MDI-X detection Configuration Auto-negotiation Transmission rate 10Mbps, 100Mbps Duplex support Full/Half duplex Network cable Cat.5 UTP up to 100 meters Fiber Ports Connectors ST, SC, VF-45, Bi-Directional SC (model dependent) Configuration 100Mbps, Full duplex Network cables MMF 50/125 60/125 μm, SMF 9/125 μm Eye safety IE
Краткое содержание страницы № 8
Forwarding & filtering Non-blocking, full wire speed Switching technology Store and forward Maximum packet length 1536 bytes max. Flow control IEEE 802.3x pause frame base for full duplex operation Back pressure for half duplex operation Broadcast Storm Protection design DC Power Interface Interface Screw-type terminal block 1. Two pairs for power wire cascading 2. One pair for alarm relay output DC Jack (-D6.3mm/+D2.0mm) Operating voltages +7V ~ +50V(+5%) Power consumption KSD-103
Краткое содержание страницы № 9
Certificate FCC Part 15 Class B CE/EMC EMI EN50081-1 Class B EMS EN55024 CE/LVD Safety EN 60950 EN 50081-1/1992 : EN55022:1994/A1:1995/A2:1997 EN61000-3-2:2000 EN61000-3-3:1995/A1:2001 EN 55024:1998/A1:2001 IEC 61000-4-2:1995 ESD Test IEC 61000-4-3:1995 RS Test IEC 61000-4-4:1995 EFT/BURST Test IEC 61000-4-5:1995 Surge Test IEC 61000-4-6:1996 CS Test IEC 61000-4-8:1993 Magnetic Field IEC 61000-4-11:1994 Voltage Int. Dips 9/20
Краткое содержание страницы № 10
2. Installation 2.1 Unpacking Check that the following components have been included: Information CD The device unit DIN-rail mounting bracket If any item is found missing or damaged, please contact your local reseller for replacement. The following are available optional accessories: Panel Mounting Bracket The bracket is used for mounting the device on a panel surface. Commercial-rated AC power adapters: - Rated input AC120V/60Hz, AC230V/50Hz, AC100V/50-60Hz, AC240V/50Hz -
Краткое содержание страницы № 11
label. If you are not sure of the type of power source required, consult your service provider or local power company. 2.3 DIN-Rail Mounting In the product package, a DIN-rail bracket is installed on the device for mounting the device in a industrial DIN-rail enclosure. The steps to mount the device onto a DIN rail are: 1. Install the mounting bracket onto the device unit as shown below: 2. Attach bracket to the lower edge of the DIN rail and push the unit upward a little bit until
Краткое содержание страницы № 12
The final mechanical dimensions after installing DIN rail mounting bracket are: 2.4 Panel Mounting The product is provided with an optional bracket for panel mounting. The bracket supports mounting the device on a plane surface securely. The mounting steps are: 1. Install the mounting bracket on the device unit. Screw the bracket on the device unit. 2. Screw the device unit on a panel. Make sure that there are proper heat dissipation from and adequate ventilation around the device. D
Краткое содержание страницы № 13
2.5 Applying Power The power specifications of the device are: Operating Voltage +7 ~ +50VDC Power Consumption 4W max. @+50VDC Using Terminal Blocks Either DC1 interface or DC2 interface can be used to receive DC power from an external power system. Or, DC2 also can be used to deliver the power received on DC1 to next device in cascading way. DC1 +Vdc Positive (+) terminal DC1 -Vdc Negative (-) terminal DC2 +Vdc Positive (+) terminal DC2 -Vdc Negative (-) terminal
Краткое содержание страницы № 14
If cascading the power to next device is needed, install the power wires and plug for another switch. Then, use DC2 contacts. Note: Only up to four device units can be cascaded to receive power from one main power input source. Using DC Power Jack DC Jack Connector: D 6.3mm D 2.0mm AC Power Adapters: Optional power adapters are available for purchasing. Connect power adapter DC plug to the DC power jack of the converter before connecting to the AC outlet. Connect the power adapt
Краткое содержание страницы № 15
Use the provided 2P terminal plug for signal wiring and plug into the PF+/- contacts. Relay Output Normal PF+ and PF- contacts shorted Indication Alarm PF+ and PF- contacts open Alarm Events: Input power failure Specific fiber port link down (To specify the fiber ports, use the DIP SW located on bottom.) KSD-103-A SW1 ON Enable broadcast storm protection OFF Disable broadcast storm protection SW2 ON Enable FX port link down alarm OFF Disable FX port link alarm KSD-103-B S
Краткое содержание страницы № 16
3. Making LAN Connections 3.1 Making Copper Port (RJ-45) Connections The copper ports support the following connection types and distances: Network Cables 10BASE-T: 2-pair UTP Cat. 3,4,5 , EIA/TIA-568B 100-ohm 100BASE-TX: 2-pair / 4-pair UTP Cat. 5, EIA/TIA-568B 100-ohm Link distance: Up to 100 meters Auto MDI/MDI-X Function This function allows the port to auto-detect the twisted-pair signals and adapts itself to form a valid MDI to MDI-X connection with the remote connected devi
Краткое содержание страницы № 17
3.3 LED Indication KSD-103-A KSD-103-B LED Function State Interpretation PWR Power status ON The power is supplied to the device. OFF The power is not supplied to the device. UTPx Copper port link status ON Port link is established. (No traffic) BLINK Port link is up and there is traffic. OFF Port link is down. FXx Fiber port link status ON Port link is established. (No traffic)
Краткое содержание страницы № 18
4. Applications 4.1 Application in Industrial Networks The following figure illustrates an application example in an industrial network. Four devices are cascaded by fiber cables. 4.2 Copper to Fiber Bridging Media Converter Application 4.3 Bridging Multimode to Single Mode Fiber Converter Application 18/20
Краткое содержание страницы № 19
5. Appendix 5.1 Model Definition KSD-103-A Model Ext. FX Connector Cable Ref. Distance Operating Temperature o -T Duplex ST MMF 2km -10 ~ 70 C o -C Duplex SC MMF 2km -10 ~ 70 C o -C1 Duplex SC MMF 2km -20 ~ 70 C o -SA2 Duplex SC SMF 20km -20 ~ 70 C o -SL2 Duplex SC SMF 20km -20 ~ 70 C o -SL3 Duplex SC SMF 30km -20 ~ 70 C o -SL4 Duplex SC SMF 40km -20 ~ 70 C o -SL6 Duplex SC SMF 60km -20 ~ 70 C o -W3515 BiDi SC SMF 15 ~ 20km -20 ~ 70 C o -W5315 BiDi SC SMF 15 ~ 20km -20 ~ 70 C KS
Краткое содержание страницы № 20
5.2 Optical Specifications KSD-103-A Model Ext. FX Port Wavelength TX Power Sensitivity RX Max. Power -T FX 1310nm -19 ~ -14dBm -31dBm -14dBm -C FX 1310nm -19 ~ -14dBm -31dBm -14dBm -C1 FX 1310nm -20 ~ -14dBm -31dBm 0dBm -SA2 FX 1310nm -15 ~ -8dBm -31dBm -7dBm -SL2 FX 1310nm -15 ~ -8dBm -30dBm 0dBm -SL3 FX 1310nm -15 ~ -8dBm -34dBm 0dBm -SL4 FX 1310nm -5 ~ 0dBm -34dBm 0dBm -SL6 FX 1310nm -5 ~ 0dBm -35dBm 0dBm -W3515 FX 1310nm -14 ~ -8dBm -31dBm 0dBm -W5315 FX 1550nm -14 ~ -8dBm -31dBm