Краткое содержание страницы № 1
Corporate Headquarters
GarrettCom, Inc.
Magnum S14 Convenient Switch
213 Hammond Ave.
(A member of Converter Switch family)
Fremont, CA 94539
Phone (510) 438-9071
Fax (510) 438-9072
Website: http://www.GarrettCom.com
email support@garrettcom.com
Installation and User Guide
www .. GarrettCom com www .. GarrettCom com
Краткое содержание страницы № 2
S14 Convenient Switch Installation and User Guide (09/04) Magnum ™ S14 Convenient Switch ™ Installation and User Guide Part #: 84-00100 Rev. A (06/04) Trademarks GarrettCom, Magnum, Link-Loss-Learn, S-Ring, Convenient Switch and Converter Switch are trademarks and Personal Hub is a registered trademark of GarrettCom, Inc. Ethernet is a trademark of Xerox Corporation NEBS is a registered trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories I
Краткое содержание страницы № 3
S14 Convenient Switch Installation and User Guide (09/04) Federal Communications Commission Radio Frequency Interference Statement This equipment generates, uses and can radiate frequency energy and if not installed and used properly, that is in strict accordance with the manufacturer's instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of
Краткое содержание страницы № 4
S14 Convenient Switch Installation and User Guide (09/04) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 213 Hammond Ave. Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com Email: support@garrettcom.com www .. GarrettCom com iii
Краткое содержание страницы № 5
S14 Convenient Switch Installation and User Guide (09/04) TABLE OF CONTENTS Page 1.0 SPECIFICATIONS...............................................................................1 1.1 Technical Specifications ..................................................................... 1 2.0 INTRODUCTION...............................................................................10 2.1 Inspecting the Package and the Product............................................. 10 2.2 Pro
Краткое содержание страницы № 6
S14 Convenient Switch Installation and User Guide (09/04) 3.7 S14H, DC-powered, -48VDC, 24VDC and 9VDC Installation ....... 38 3.8 Connecting Twisted Pair (RJ-45 ports).............................................. 40 3.8.1 Connecting Twisted Pair (RJ-45, CAT 3 or CAT 5) ................ 41 3.8.2 Connections to NICs which support Auto-Negotiation ............. 42 4.0 OPERATION.......................................................................................42 4.1 Dual-Speed Func
Краткое содержание страницы № 7
S14 Convenient Switch Installation and User Guide (09/04) Revisions 10/04: Small edit and updates on power supply option. 09/04: Small edit and updates on UL. 06/04: Small revision of the Agency Approvals Rev A 03/04: Initial release of this user manual for the S14 Converter Switch GarrettCom, Inc. reserves the right to change specifications, performance characteristics and/or model offerings without notice. www .. GarrettCom com vi
Краткое содержание страницы № 8
S14 Convenient Switches Installation and User Guide (09/04) 1.0 SPECIFICATIONS 1.1 Technical Specifications Ports Performance When a port is operating at 100Mbps: Data Rate: 100Mbps When a port is operating at 10 Mbps: Data Rate: 10 Mbps Network Standards 100Mb: Ethernet IEEE 802.3u, 100BASE-TX, 100BASE-FX 10 Mb: Ethernet IEEE 802.3, 10BASE-T Auto-sensing for speed: IEEE 802.3u
Краткое содержание страницы № 9
S14 Convenient Switches Installation and User Guide (09/04) Address buffer age-out time: 300 sec. Packet buffers memory: 128KB,dynamically shared on all domains Latency (not including packet time): 100 to 10 Mbps: 5 µs 10 to 100Mbps: 5 µs Path Delay Value: 50 BT on all ports Maximum Ethernet Segment (or Domain) Lengths 10BASE-T (Unshielded twisted pair) - 100 m (328 ft) 100BASE-TX (CAT 5 UTP) - 100 m (328 ft) Operating Environment Ambient Temperature (S14):
Краткое содержание страницы № 10
S14 Convenient Switches Installation and User Guide (09/04) -58ºF to 212ºF (-50ºC to 100ºC) Short term per IEC Type tests Storage Temperature, All models: -40ºF to 160ºF (-40ºC to 85ºC) Cold Start: (S14H) model to -20ºC (S14P) model to -40ºC Ambient Relative Humidity: 5% to 95% (non-condensing) Altitude (All models): -200 to 5000ft. (-60 – 15,000 m) Conformal Coating (optional) Humidity pr
Краткое содержание страницы № 11
S14 Convenient Switches Installation and User Guide (09/04) –Hd, and Hi: 5.8 oz (165g) –Pd, and =Pi: 7.9 oz (225g) Cooling Method: Convection on regular model, plus the case is used as a heat sink on “H” and “P” models. POWER SUPPLY These products are intended to be supplied by a Listed, Direct Plug-In power unit, marked “Class 2”, or a Listed ITE Power Supply, marked “LPS”, which has suitably rated output voltage (i.e. 9vdc, 12vdc, 24vdc, 48vdc), and
Краткое содержание страницы № 12
S14 Convenient Switches Installation and User Guide (09/04) Input: 120vac at 60 Hz for “d” models, 240vac at 50Hz for “i” models that have IEC320 power connector built-in the PS unit. Out put- 12vdc, 1 Amps Input: 100-240V AC at 47-63Hz, for “-Hd” high temp., 100-240V AC at 47-63Hz “-for Hi” models that have IEC320 power connector built-in the PS unit. Out put- 12vdc, 1.25 Amps Input: 100-240V AC at 47-63Hz, for “-Pd” high temp. 100-240V AC at 47-63Hz, “-Pi” models that have
Краткое содержание страницы № 13
S14 Convenient Switches Installation and User Guide (09/04) -48V DC internal (range of 36 to 60V DC) t. Power Consumption: 3 watts typical, 4 watts max. Note 1: 8-15V DC can be used for dual source DC input Note 2: Internal DC power floats, user may ground “+” or “-” if desired. Port Connectors: RJ-45 Port: Auto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded (STP) and unshielded (UTP)
Краткое содержание страницы № 14
S14 Convenient Switches Installation and User Guide (09/04) Mounting option for S14 Family of Switches: Metal Mounting clips for panel mounting : included DIN-Rail mounting option: Model # DIN-RAIL MC2 (see Section 3.4) Rack-mount option: MC14-TRAY, see http://www.garrettcom.com/mc_tray.htm Mean Tine Between Failure (MTBF) – 15+ years, Telcordia (Bellcore) Method Agency Approvals and Standard Compliance: UL Listed (UL 60950), cUL, CE, Emissions meet FCC Part 15, Class A. N
Краткое содержание страницы № 15
S14 Convenient Switches Installation and User Guide (09/04) Warranty: Three years, return to factory Made in USA www .. GarrettCom com 8
Краткое содержание страницы № 16
S14 Convenient Switches Installation and User Guide (09/04) 1.2 Summary of models and descriptions: S14-d,i = four 10/100 RJ-45 ports Switch, for office and wiring closet env., ext. AC Pwr Supply S14H-Hd, Hi = Hardened, four 10/100 RJ-45 ports Switch, Factory floor, Int. 8-15VDC, Ext. AC Hardened power supply included . S14H-12VDC = Same as S14H model, except Ext. AC Hardened power supply not included S14H-24VDC = Same as S14H-12VDC model, except for 24VDC power input S14HR-2
Краткое содержание страницы № 17
S14 Convenient Switches Installation and User Guide (09/04) 2.0 INTRODUCTION This section describes S14-Series models, including appearance, features and typical applications. 2.1 Inspecting the Package and the Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier immediately of any damage which you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that th
Краткое содержание страницы № 18
S14 Convenient Switches Installation and User Guide (09/04) Remove the Magnum S14-Series Switch from the shipping container. Be sure to keep the shipping container should you need to ship the unit at a later date. In the event there are items missing or damaged contact your supplier. If you need to return the unit use the original shipping container. Refer to Section 5 Troubleshooting, for specific return procedures. 2.2 Product Description The Magnum S14 family of Convenient Swi
Краткое содержание страницы № 19
PO RT 4 WWW.GarrettCom.Com S14 Convenient Switches Installation and User Guide (09/04) PORT 3 PORT 1 PORT 2 8 15V DC – GarrettCom GarrettCom S14 PORT 4 Fig. 2.2a Left Side View Magnum S14 Convenient Switch Fig2.1a. Magnum S14, Front view (three RJ-45 ports on Front side of the unit, as shown in Fig Fig2.2a. Magnum S14, Rear view (one RJ-45 port on rear GarrettCom Magnum S14 side) Convenient Switch
Краткое содержание страницы № 20
S14 Convenient Switches Installation and User Guide (09/04) The Yellow label, S14 shown above in regular-package units are for office and wiring closet environments, uses an external AC power supply. A metal case with convection cooling is featured. Operation may be in 0° to 50°C ambient temperature. The units can be mounted securely on a closet wall or metal cabinet, or by using the metal panel mounting clips included. The orange-label Magnum S14H as shown above in Fig 2.2c, are har