Краткое содержание страницы № 1
Magnum P62-Series
Corporate Headquarters
(P62F and managed mP62 models)
GarrettCom, Inc.
Hardened Ethernet Switches
213 Hammond Avenue
Fremont, CA 94539
Phone: 510.438.9071
Fax: 510-438-9072
Web: www.GarrettCom.com
Email: support@Garrettcom.com
Installation and User Guide
ww www w .. .. Ga Garrrre ettttC Co om m c co om m
www .. GarrettCom com
Краткое содержание страницы № 2
Краткое содержание страницы № 3
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Magnum ™ P62-Series (P62F and managed mP62 models) Hardened Ethernet Switches Installation and User Guide Part #: 84-00092, (Rev I 11/03) Trademarks Ethernet is a trademark of Xerox Corporation NEBS is a trademark of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories GarrettCom, Magnum, Personal Switch, S-Ring Redundancy Manager (patent pending)
Краткое содержание страницы № 4
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Contacting GarrettCom, Inc Please use the mailing address, phone and fax numbers and email address listed below: GarrettCom, Inc. 47823 Westinghouse Drive Fremont, CA 94539 Phone (510) 438-9071 Fax (510) 438-9072 Website: http://www.GarrettCom.com email support@garrettcom.com Federal Communications Commission Radio Frequency Interference Statement This equipmen
Краткое содержание страницы № 5
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) MAGNUM ETHERNET CONNECTIVITY PRODUCTS "DESIGNED AND MANUFACTURED IN THE USA" Overview GarrettCom, Inc. offers the Magnum line of Ethernet LAN connectivity products with industry-standard functionality. Magnum products are heavy duty, feature fiber-built-in ports, and have AC and DC power options to make them suitable for a variety of Industrial and Carrier Class applications. 6K25
Краткое содержание страницы № 6
Краткое содержание страницы № 7
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) TABLE OF CONTENTS PAGE 1.0 SPECIFICATIONS..............................................................................................2 1.1 Technical Specifications ...................................................................................2 1.2 Ordering Information...............
Краткое содержание страницы № 8
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Rev B 08/01: This revision includes the update of additional power source Rev A 04/01: This revision is the initial release of the P62F Hardened Switches user manual. 1.0 SPECIFICATIONS 1.1 Technical Specifications Ports Performance Fiber, and when an auto-negotiating port is operating at 100Mbps: Data Rate: 100Mbps When an RJ-45 auto-neg
Краткое содержание страницы № 9
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Operating Shock and Vibration: Meets Bellcore GR-63-CORE Conformal coating (tropical humidity protection) optional, request quote Power Supply (Internal) 24VDC and -48VDC Power Supply Power Input Voltage: 20 to 60 VDC (auto-ranging), “-, GND, +” Power Consumption: 10 watts typical. DC-DC Converter Rating: 5VDC, 2Amps Power Supply (Ext.) 125VDC & 250VDC, (PSX-T) fo
Краткое содержание страницы № 10
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) is transmitting / receiving. F/H (RJ-45 ports only): ON = full-duplex, OFF = half-duplex MTBF (Bellcore method) Over 10 years MTBF. Email sales@GarrettCom.com for details Agency Approvals UL Listed (UL 60950), cUL, CE Emissions meet FCC part 15, Class A. NEBS L3 and ETSI compliant. IEEE P1613 Environmental Standard for Electric Power Substations. IEC61850
Краткое содержание страницы № 11
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) 1.2 Ordering Information Magnum P62-Series, 10/100 Ethernet Switch Magnum P62F-AC-2MSC: P62F-AC Ethernet Switch with six 10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Has 16KB address table and 1.0 MB packet buffers. AC power input, 85-160vac 47-63Hz worldwide auto-ranging via PSX-A power source Extended Temp ( a separate unit). Steel case used as a heat sink, d
Краткое содержание страницы № 12
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) Magnum Model P62F-5V Switch. Magnum PSX-T: Same as PSX-A , except 125VDC to 250VDC input, terminal lugs for “+”, “-“, and GND Managed P62-Series (mP62) Hardened Switches Magnum mP62-AC-2MSC: mP62-AC Managed Switch with six10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Software includes menu-driven user interface for ease of use, SNMP, QoS, Telnet, Security,
Краткое содержание страницы № 13
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) 2.0 INTRODUCTION 2.1 Inspecting the Package and Product Examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during shipment or delivery. Inspect the contents of this package for any signs of damage and ensure that the items listed below are included. This package should contain: 1 Magnum P62-
Краткое содержание страницы № 14
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) 2.2 Product Description The Magnum P62-Series Ethernet “Outdoor” Switches are designed to operate in extended temperature applications and are suitable for use in environments with inhospitable high / low temperatures. Magnum P62-Series Hardened switches provide two built-in 100Mb full- duplex switched fiber ports so that several units can be daisy-chained. These fiber ports are coupl
Краткое содержание страницы № 15
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) performance plug-and-play operation in a rugged package. The high-strength steel enclosure gives extra protection. Each P62-Series Hardened Switch is non-blocking on all ports and has large packet buffers and a 4K-node address table for advanced performance. A Magnum P62-Series Switch, with store-and-forward switching ability, filters all faulty packets to minimize traffic congestion.
Краткое содержание страницы № 16
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) The Magnum P62-5V models are available with an External Power Source (Optional) for power input of universal AC power using the Magnum PSX-A unit. The 125/250 VDC model (PSX-T) input power supports a range of 100-275VDC and comes with input safety shield, fuses, and is diode-protected against accidental reverse polarity connection. The AC Power Source, PSX-A, is equipped with a worldw
Краткое содержание страницы № 17
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) The serial (Console) port is provided on the right front of the Managed mP62 Switch to use the Console Management Interface(CMI) to manage all functions of the switch. In addition, the Link-Loss-Learn ™ feature (patent pending) in mP62’s allows rapid operating recovery from a link loss. The Link-Loss-Learn feature of the Magnum mP62 Ethernet Switch addresses issues that can occur whe
Краткое содержание страницы № 18
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) format, a separate document normally accessed via the web-browser, ftp://ftp.garrettcom.com/ or FTP client program by ftp.GarrettCom.com using user : mpuser password : mpuser All the MNS-mP Software related information and NEW releases related to MNS-mP Software and Hardware for mP62’s can be accessed and download from Garrettcom’s FTP site. Or please visit www.GarrettCom.com/
Краткое содержание страницы № 19
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) 2.2.5 RS-232 (DB-9) Console Com. port pin assignments. Pin 1 Pin 5 DB-9 (Console port connector) Pin Signal Description 1 CD Carrier detect (not used) 2 RXD Receive Data (input) 3 TXD Transmit Data (output) 4 open not used 5 GND Signal Ground 6-9 open not used The above provided information enables a managed station( a PC or
Краткое содержание страницы № 20
Magnum P62-Series Hardened Switches Installation and User Guide (11/03) On Magnum P62-Series units, there are three LED’s for each of the RJ-45 switched ports. The F/H indicates full-duplex when ON or half-duplex when OFF. The (LK/ACT) LED is steady ON to indicate LINK, and blinking to indicate transmitting / receiving. The 10/100 LED is ON for 100Mbps and OFF for 10 Mbps (when LINK is made). For fiber ports, the LEDs are the same except there is no F/H