Краткое содержание страницы № 1
Foundry NetIron
M2404C and M2404F
Metro Access Switches
Installation Guide
™
4980 Great America Parkway
Santa Clara, CA 95054
Tel 408.207.1700
www.foundrynetworks.com
January 2007
Краткое содержание страницы № 2
Copyright © 2007 Foundry Networks, Inc. All rights reserved. No part of this work may be reproduced in any form or by any means – graphic, electronic or mechanical, including photocopying, recording, taping or storage in an information retrieval system – without prior written permission of the copyright owner. The trademarks, logos and service marks ("Marks") displayed herein are the property of Foundry or other third parties. You are not permitted to use these Marks without the prior
Краткое содержание страницы № 3
Foundry NetIron M2404C/M2404F Metro Access Switches Safety Considerations This equipment is for use in a restricted access area by qualified personnel only. To avoid electric shock, do not perform any servicing other than those contained in the unpacking instructions. This equipment contains Electrostatic Discharge (ESD) sensitive components. Use ESD protection before servicing or installing components of this system. CAUTION Changes or modifications made to this device that are not exp
Краткое содержание страницы № 4
Foundry NetIron M2404C/M2404F Metro Access Switches WARNING GROUNDING Before connecting the product to the power line, make sure that the protective ground terminal of the device is connected to the safety ground conductor of the mains power cord. The main power supply plug should only be inserted in a socket outlet provided with a connected safety ground. The protective action must not be negated by use of an extension cord (power cable) without a protective conductor (grounding).
Краткое содержание страницы № 5
Foundry NetIron M2404C/M2404F Metro Access Switches Table of Contents ABOUT THIS DOCUMENT......................................................................................... 1 WHO SHOULD USE THIS GUIDE ..................................................................................... 1 HOW THIS DOCUMENT IS ORGANIZED ........................................................................... 1 CONVENTIONS USED IN THIS DOCUMENT .......................................................
Краткое содержание страницы № 6
Foundry NetIron M2404C/M2404F Metro Access Switches SOFTWARE IMAGE NAMING CONVENTIONS ................................................................. 26 DOWNLOADING A SOFTWARE IMAGE TO THE SWITCH USING TFTP ............................ 26 Preparing to Download an Image Using TFTP...................................................... 26 Downloading a Device Software Image Using TFTP............................................. 26 Downloading a NI-M2404WebView Image Using TFTP ...........
Краткое содержание страницы № 7
Foundry NetIron M2404C/M2404F Metro Access Switches About This Document Who Should Use This Guide The procedures in this manual are for trained and qualified service personnel who are proficient with network switching and routing concepts. Installation, replacement and maintenance of the equipment described in this guide may only be done by trained and qualified service personnel. How This Document is Organized This document contains the following chapters. Chapter Contains 1. About T
Краткое содержание страницы № 8
Foundry NetIron M2404C/M2404F Metro Access Switches Conventions Used in this Document This document uses the following formatting styles and conventions: • CLI syntax and coded examples are represented by mono-space characters and enclosed in rectangular frames. Under this category: o Text issued by the device software is represented by regular characters. o In command syntax specifications, text to be entered by the user is represented as follows: Command names and keywords appear as
Краткое содержание страницы № 9
Foundry NetIron M2404C/M2404F Metro Access Switches Overview Introduction High powered networks require a combination of speed and robust services support to be able to provide the intensive and fluctuating demands of their end users. To answer these requirements, the network needs to provide data transmission at wire speed performance in a non-blocking fashion. This switch is an enhanced Metro Ethernet CPE platform designed to provide wire speed non-blocking Layer-2 and Layer-3 switchi
Краткое содержание страницы № 10
Foundry NetIron M2404C/M2404F Metro Access Switches Hardware Description Front Panel Enhanced GigE Ports 100baseX Ports GigE Ports Switch Management Ports (Outband Port on PSU LEDs Reset Button top and Console Port on bottom) Figure 3: NetIron M2404F Platform Front Panel Enhanced GigE Ports 10/100baseTX Ports GigE Ports Switch Management Ports (Outband Port on PSU LEDs Reset Button top and Console Port on bottom) Figure 4: NetIron M2404C Platform Front Panel To prepa
Краткое содержание страницы № 11
Foundry NetIron M2404C/M2404F Metro Access Switches 3. Gently insert the SFP tranceiver into the port until the module clicks into place. The module is keyed to prevent incorrect insertion. See Figure 5. Important Note When inserting an SFP tranceiver into ports marked 27 or 28, verify that the SFP is facing upside -down (as shown in figure below). All other SFP ports on the switch face right-side up. Figure 5: Inserting an SFP, upside-down, into the Enhanced GigE Slot NetIron M240
Краткое содержание страницы № 12
Foundry NetIron M2404C/M2404F Metro Access Switches Component Description GigE Dual-Mode Ports Two dual-mode1000baseX interface (SFP) or 10/100/1000BaseT (RJ45) marked 25 and 26. Enhanced GigE Ports Two 1000baseX interface (SFP) marked 27 and 28. Please note that the SFP transceivers are inserted into the slot, belly-down, as shown in figure above. Console Management RJ45 socket for CLI configuration and management of the unit. Port Ethernet Management RJ45 socket with 10/100 Mbps LAN
Краткое содержание страницы № 13
Foundry NetIron M2404C/M2404F Metro Access Switches Port Status LEDs A status LED is associated with each port. Port Status Indication Link Green Activity Blinking green Fault/disabled Amber NetIron M2404C Port Status LEDs Port 1 Port 3 Port 5 Port 7 Port 9 Port 11 Port 4 Port 6 Port 8 Port 12 Port 2 Port 10 Figure 6: Location of NetIron M2404C Port Status LEDs The port status LEDs (1 to 24) for NetIron M2404C are situated on the upper row of ports. The LED on the left side o
Краткое содержание страницы № 14
Foundry NetIron M2404C/M2404F Metro Access Switches NetIron M2404F Dual-Mode Port Status LEDs Figure 8: Location of NetIron M2404F Dual-Mode Port Status LEDs Dual-mode port status LEDs are associated with dual-mode RJ45/SFP GiGE ports 25 and 26. RJ-45 Indicators RJ45 Dual-Mode Port Status Indication Link/Activity Left LED is Green Right LED is Amber Disabled SFP Indicators SFP Dual-Mode Port Status Indication Link Green Activity Blinking green Disabled Amber January 2007 © 2007
Краткое содержание страницы № 15
Foundry NetIron M2404C/M2404F Metro Access Switches Rear Panel – with AC Power-Supply Units Hot-swappable PSU #2 Fan apertures Hot-swappable PSU #1 On-off AC-Power Grounding studs On-off AC-Power switch inlet switch inlet Figure 9: Rear Pane l with AC PSUs Panel Main Components Two AC Power supplies As specified in Power Supply Units. Two grounding posts Designed for a UL-listed two-hole long-barrel 5/8 10 AWG compression lug. Burndy YAZV10-2TC14 or an equivalent is recommended
Краткое содержание страницы № 16
Foundry NetIron M2404C/M2404F Metro Access Switches Rear Panel – with DC Power-supply Units Hot-swappable PSU #2 Fan apertures Hot-swappable PSU #1 Terminal PWR and Grounding studs Terminal PWR and block Invert. Con. block Invert. Con. LEDs LEDs Figure 10: Rear Panel with DC PSUs Panel Main Components Two DC Power supplies As specified in Power Supply Units. Two grounding posts Designed for a UL-listed two-hole long-barrel 5/8 10 AWG compression lug. Burndy YAZV10-2TC14 or an eq
Краткое содержание страницы № 17
Foundry NetIron M2404C/M2404F Metro Access Switches DC power-supply terminals: LEDs: -48V/3A GND +BAT.RET INVERT CON. PWR Figure 12: DC Power Supply Unit The DC power supply panel has the following components: Input terminals: -48V/3A Negative DC input terminal GND Ground terminal internally connected to the platform’s ground line +BAT.RET Positive DC input terminal NOTE Neither the +BAT.RET nor the -48VDC is connected to the GND terminal. If required, this
Краткое содержание страницы № 18
Foundry NetIron M2404C/M2404F Metro Access Switches Figure 13 Blank Filler for Empty Power-Supply Slot January 2007 © 2007 Foundry Networks, Inc. 12
Краткое содержание страницы № 19
Foundry NetIron M2404C/M2404F Metro Access Switches Installation and Setup This section provides installation and setup instructions. The platform can be installed in a standard 19-inch rack or as a standalone unit in a desktop configuration. Packing List The shipping package includes the following items: • NetIron M2404F /NetIron M2404C platform. • One AC (ACPS) or DC (DCPS) power-supply unit, installed. • One power cable. • Two rack-mounting brackets with screws • Console cable •
Краткое содержание страницы № 20
Foundry NetIron M2404C/M2404F Metro Access Switches WARNING Make sure the rack or cabinet housing the device is adequately secured to prevent it from becoming unstable or falling over. Rack Mounting Specifications Width Basic body: 440 mm (17.4”) Overall, including brackets: 483 mm (19”) Height 44 mm (1.73”) = 1 RU Depth 414 mm (16.3”) Distance between mounting holes Horizontal: 465 mm (18.3”) Vertical: 31.75 mm (1.25”) Vertical separation: 12.7 mm (0.5”) Note that there is no n