Краткое содержание страницы № 1
VigorSwitch P2260
User’s Guide
Version: 1.0
Date: 2008/12/08
Cop27
yright 2008 All rights reserved.
Краткое содержание страницы № 2
Copyright Information Copyright Copyright 2008 All rights reserved. This publication contains information that is Declarations protected by copyright. No part may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language without written permission from the copyright holders. Trademarks The following trademarks are used in this document: Microsoft is a registered trademark of Microsoft Corp. Windows, Windows 95, 98, Me, NT, 2000, XP and
Краткое содержание страницы № 3
European Community Declarations Manufacturer: DrayTek Corp. Address: No. 26, Fu Shing Road, HuKou County, HsinChu Industrial Park, Hsin-Chu, Taiwan 303 Product: VigorSwitch Series Device The product conforms to the requirements of Electro-Magnetic Compatibility (EMC) Directive 2004/108/EC by complying with the requirements set forth in EN55022/Class A and EN55024/Class A. The product conforms to the requirements of Low Voltage (LVD) Directive 2006/95/EC by complying with the require
Краткое содержание страницы № 4
T Ta ab blle e o of f C Co on nt te en nt ts s 1 Preface ...............................................................................................................1 1.1 Overview ................................................................................................................................. 1 1.2 Features .................................................................................................................................. 2 1.3 Packing List.............
Краткое содержание страницы № 5
2.8.2 Tag-based Group............................................................................................................ 55 2.8.3 PVID................................................................................................................................ 56 2.8.4 Port-based Group ........................................................................................................... 57 2.8.5 Management VLAN ................................................................
Краткое содержание страницы № 6
2.19.2 Loopback Test ............................................................................................................ 110 2.19.3 Ping Test..................................................................................................................... 110 2.20 TFTP Server.......................................................................................................................111 2.21 Log ...........................................................................
Краткое содержание страницы № 7
1 Preface Preface In this user’s manual, it will not only tell you how to install and connect your network system but configure and monitor the VigorSwitch P2260 through the built-in CLI and web by RS-232 serial interface and Ethernet ports step-by-step. Many explanations in detail of hardware and software functions are shown as well as the examples of the operation for web-based interface and command-line interface (CLI). 1.1 Overview 1.1 Overview VigorSwitch P2260, implemented
Краткое содержание страницы № 8
Below shows key features of this device: QoS QoS Support Quality of Service by the IEEE 802.1P standard. There are two priority queue and packet transmission schedule using Weighted Round Robin (WRR). User-defined weight classification of packet priority can be based on either VLAN tag on packets or user-defined port priority. S Sp pa an nn niin ng g T Tr re ee e Support IEEE 802.1D, IEEE 802.1w (RSTP: Rapid Spanning Tree Protocol) standards. VLAN VLAN Support Port-based VLAN and
Краткое содержание страницы № 9
In 24-Port PoE L2 Managed Fast Ethernet Switch with 2 SFP Dual Media switch, it supports 2 Gigabit dual media ports(TP/SFP) and 2 slots for removable SFP module supporting 1000M SFP fiber module Supports on-line pluggable fiber transceiver modules Supports 256KB packet buffer and 128KB control memory Maximal packet length can be up to 1536 bytes Full-duplex flow control (IEEE802.3x) and half-duplex backpressure Extensive front-panel diagnostic LEDs; System: Power, CPURUN, ACT / F
Краткое содержание страницы № 10
Supports diagnostics to let administrator knowing the hardware status Supports external loopback test to check if the link is ok TFTP for firmware upgrade, system log upload and config file import/export Supports remote boot the device through user interface and SNMP Supports network time synchronization and daylight saving Supports 120 event log records in the main memory and display on the local console 1 1..3 3 P Pa ac ck kiin ng g L Liis st t Before you start installing the
Краткое содержание страницы № 11
There are 24 TP Fast Ethernet ports and 2 slots for optional removable modules on the front panel of the switch. LED display area, locating on the front panel, contains a ACT, Power LED and 26 ports working status of the switch. L LE ED D E Ex xp plla an na at tiio on n LED Color Explanation ACT Green Blinks when CPU is active. PWR Green Lit when +5V DC power is on and good Lit when LEDSET(NORM/FDX/SPD) set NORM Green on normal mode Lit when LEDSET (NORM/FDX/SPD) set FDX Green
Краткое содержание страницы № 12
U Us se er r IIn nt te er rf fa ac ce es s o on n t th he e R Re ea ar r P Pa an ne ell One RS-232 DB-9 interface is offered for configuration or management. 6 VigorSwitch P2260 User’s Guide
Краткое содержание страницы № 13
1.5 Hardware Installation 1.5 Hardware Installation At the beginning, please do first: Wear a grounding device to avoid the damage from electrostatic discharge Be sure you have inserted the power cord to power source 1 1..5 5..1 1 C Co on nn ne ec ct tiin ng g t th he e S SF FP P F Fiib be er r T Tr ra an ns sc ce eiiv ve er r t to o t th he e C Ch ha as ss siis s The optional SFP modules are hot swappable, so you can plug or unplug it before or after powering on. 1. Veri
Краткое содержание страницы № 14
1 1..5 5..2 2 IIn ns st ta alllliin ng g O Op pt tiio on na all S SF FP P F Fiib be er r T Tr ra an ns sc ce eiiv ve er rs s t to o t th he e s sw wiit tc ch h If you have no modules, please skip this section. 1 1..5 5..3 3 IIn ns st ta alllliin ng g C Ch ha as ss siis s t to o a a 1 19 9- -IIn nc ch h W Wiir riin ng g C Cllo os se et t R Ra aiill Caution: Allow a proper spacing and proper air ventilation for the cooling fan at both sides of the chassis. 1. Wear a g
Краткое содержание страницы № 15
C Ca ab blliin ng g R Re eq qu uiir re em me en nt ts s f fo or r 1 10 00 00 0S SX X//L LX X S SF FP P M Mo od du ulle e It is more complex and comprehensive contrast to TP cabling in the fiber media. Basically, there are two categories of fiber, multi mode (MM) and single mode (SM). The later is categorized into several classes by the distance it supports. They are SX, LX, LHX, XD, and ZX. From the viewpoint of connector type, there mainly are LC and BIDI LC. Gigabit Fiber with mu
Краткое содержание страницы № 16
Sum up all elements’ bit-time delay and the overall bit-time delay of wires/devices must be within Round Trip Delay (bit times) in a half-duplex network segment (collision domain). For full-duplex operation, this will not be applied. You may use the TP-Fiber module to extend the TP node distance over fiber optic and provide the long haul connection. Typical Network Topology in Deployment A hierarchical network with minimum levels of switch may reduce the timing delay between server and c
Краткое содержание страницы № 17
The same VLAN members could not be in different switches. Every VLAN members could not access VLAN members each other. The switch manager has to assign different names for each VLAN groups at one switch. Case 3: Port-based VLAN - 2 VLAN1 members could not access VLAN2, VLAN3 and VLAN4 members. VLAN2 members could not access VLAN1 and VLAN3 members, but they could access VLAN4 members. VLAN3 members could not access VLAN1, VLAN2 and VLAN4. VLAN4 members could not access VLAN1 and
Краткое содержание страницы № 18
Case 4: The same VLAN members can be at different switches with the same VID 12 VigorSwitch P2260 User’s Guide
Краткое содержание страницы № 19
1 1..5 5..5 5 C Co on nf fiig gu ur riin ng g t th he e M Ma an na ag ge em me en nt t A Ag ge en nt t o of f S Sw wiit tc ch h We offer you three ways to startup the switch management function. They are RS-232 console, CLI, and Web. Users can use any one of them to monitor and configure the switch. You can touch them through the following procedures. Configuring the Management Agent of VigorSwitch P2260 through the Serial RS-232 Port Configuring the Management Agent of VigorSw
Краткое содержание страницы № 20
Stop bits 1 Data bits 8 Parity N Flow control none 4. When you complete the connection, then press key. The login prompt will be shown on the screen. The default username and password are shown as below: Username = admin Password = admin Additionally, if a user connects VigorSwitch to VigorPro router, he also can access into VigorPro web configuration page to find out External Devices menu item. Then click the new added switch icon to ope