Only qualified personnel should perform installation procedures. NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes have been made. The hardware, firmware, or software described in this manual is subject to change without notice. IN NO EVENT SHALL CABLETRON SYSTEMS BE LIABLE FOR AN
Краткое содержание страницы № 4
Notice DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada. VCCI NOTICE
Краткое содержание страницы № 5
Notice CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE. You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement. You may not copy, reproduce or transmit any part of the Program except as permitted by the Copyright Act of the United States or as authorized in writing by Cabletron. 2. OTHER RESTRICTIONS. You may not reverse engineer, decompile, or disassemble the Program. 3. APPLICABLE LAW. This
Краткое содержание страницы № 6
Notice DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Cabletron Systems, Inc. Manufacturer’s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representative Name: Mr. J. Solari European Representative Address: Cabletron Systems Limited Nexus House, Newbury Business Park London Road, Newbury Berkshire RG13 2PZ, England Conformance to Directive(s)/Product Standards: EC Directive 89/336/EEC EC Dir
Краткое содержание страницы № 7
CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Guide......................................................................... 1-1 1.2 Structure of This Guide................................................................ 1-1 1.3 Document Conventions ............................................................... 1-2 1.4 Using the 6C105 Manual Set....................................................... 1-2 1.5 Getting Help..................................................................
Краткое содержание страницы № 8
Contents vi 6C105 Overview and Setup Guide
Краткое содержание страницы № 9
CHAPTER 1 INTRODUCTION Welcome to the Cabletron Systems 6C105 SmartSwitch 6000 Overview and Setup Guide. This guide explains how to set up and configure the Cabletron Systems 6C105 SmartSwitch 6000 chassis. 1.1 USING THIS GUIDE Read through this guide completely to familiarize yourself with its contents and to gain an understanding of the features and capabilities of the 6C105 SmartSwitch 6000. This guide lists the features and options of the 6C105 SmartSwitch 6000 and expla
Краткое содержание страницы № 10
Chapter 1: Introduction 1.3 DOCUMENT CONVENTIONS Throughout this guide the following symbols are used to call attention to important information. Note symbol. Calls the reader’s attention to any item of NOTE information that may be of special importance. Caution symbol. Contains information essential to avoid damage to the equipment. ! CAUTION Electrical Hazard Warning symbol. Warns against an action that could result in the presence of an electrical hazard. 1.4 USING THE 6C105
Краткое содержание страницы № 11
Getting Help 1.5 GETTING HELP If you need additional support related to this device, or if you have any questions, comments, or suggestions concerning this manual, contact the Cabletron Systems Global Call Center: Phone (603) 332-9400 Internet mail support@ctron.com FTP ctron.com (134.141.197.25) Login anonymous Password your email address BBS (603) 335-3358 Modem setting 8N1: 8 data bits, No parity, 1 stop bit For additional information about Cabletron Systems
Краткое содержание страницы № 12
Chapter 1: Introduction 1.6 OVERVIEW The Cabletron Systems 6C105 chassis design provides five 2.4-inch slots that can contain a variety of interface modules. The chassis supports redundant power supplies, LANVIEW Diagnostic LEDs, and is 19-inch rack mountable. All chassis components (power supplies, fan tray, and modules) are installed from the front of the chassis for ease of maintenance. All LED indicators are observable from the front of the chassis to aid in monitoring network op
Краткое содержание страницы № 13
Features 1.7 FEATURES Redundant Power Supply Modules The 6C105 supports two power supply modules which reside in the slots labeled PS1 and PS2. If the 6C105 is configured with a single power supply module it must be located in slot PS1. ! CAUTION Installing one ac power supply and one DC power supply in the same chassis is NOT allowed. Each power supply module supports an ac input connector that allows each power supply to be connected to a separate ac power source. Ca
Краткое содержание страницы № 14
Chapter 1: Introduction Auto-Ranging Power Supplies The 6C105 power supply modules automatically adjust to the input voltage and frequency. No additional adjustments are necessary. Hot Swapping To reduce network downtime, the power supply modules are also hot swappable. This allows for the removal of one power supply without powering down the chassis and interrupting network traffic. The 6C105 Cooling System The 6C105 features a removable fan tray that is accessible from the front
Краткое содержание страницы № 15
CHAPTER 2 INSTALLATION REQUIREMENTS AND SPECIFICATIONS This chapter describes the following: • Site guidelines that must be met before installing a 6C105 into a rack or cabinet • 6C105 configuration guidelines • Operating specifications for the 6C105 enclosure and power supply modules Only qualified personnel should install or service this unit. 2.1 SITE GUIDELINES The following guidelines must be followed when a site is selected for the 6C105. If the guidelines are no
Краткое содержание страницы № 16
Chapter 2: Installation Requirements and Specifications 2.2 CONFIGURATION GUIDELINES The 6C105 has 5 slots that accept interface modules. The slots are numbered 1 to 5 beginning from the left. There are two additional slots located on the far right of the chassis that are reserved for power supply modules. These slots are labeled PS1 and PS2. Cabletron Systems modules for the 6C105 are equipped with a firmware-based management tool called Local Management, which provides the capabi
Краткое содержание страницы № 17
Operating Specifications 2.3.1 Physical Specifications The physical specifications for the 6C105 chassis, 6C205-1, 6C205-2, 6C205-3 power supply modules and the 6C405 fan tray module are as follows: 6C105 Chassis Dimensions: 62.23 H x 44.04 W x 35.56 D (cm) 24.5 H x 17.34 W x 14 D (in) Weight (with factory 11.7 kg (26 lb) installed fan tray): 6C205-1 Power Supply Dimensions: 44.63 H x 6.05 W x 32.77 D (cm) 17.57 H x 2.38 W x 12.9 D (in) Weight: 3.65 kg (8.1 lb) 6C205-2 Power Supply Dimensions: 4
Краткое содержание страницы № 18
Chapter 2: Installation Requirements and Specifications 2.3.2 Power Supply Requirements The power supply requirements for the 6C205-1, 6C205-2 and 6C205-3 power supply modules are as follows: 6C205-1 AC Power Supply Input Frequency: 50/60 Hz Input: (Voltage/Current): 100 to 125 Vac, 6.2 Amps 200 to 250 Vac, 3.1 Amps 6C205-2 DC Power Supply Input Frequency: NA Input: (Voltage/Current): 48/60 Vdc, 17 Amps 6C205-3 AC Power Supply Input Frequency: 50/60 Hz Input: (Voltage/Current): 100 to 125 Vac,
Краткое содержание страницы № 19
LEDs Table 2-1 Power Supply LED States and Their Definitions LED Name Color Status PWR (Power) Green All outputs and input of the power supply are within regulation. Red Any output or input of the specific power supply is out of regulation. REDUNDANCY Green Redundancy is available. Amber Redundancy is possible, but not available (two power supplies are installed). Off Redundancy not possible. (One power supply installed.) Redundancy LED PWR LED 2016_03 Figure 2-1 Power Supply LEDs 6C105 Over
Краткое содержание страницы № 20
Chapter 2: Installation Requirements and Specifications 2.4.2 Fan Tray LED The following table describes the different states of the fan tray LED and their definitions. Refer to Figure 2-2 for the location of the fan tray LED. Table 2-2 Fan Tray LED States and Their Definitions LED Color Status Green All fans are operating normally. Red One or more fan failures have occurred. When the 6C105 is first powered up, the Fan Tray LED will NOTE display red briefly, until the fans are operating at the pr