Краткое содержание страницы № 1
ENG ENG FRE GER SPA ITA JAP RUS CZE TUR
SCX-RD100
COAXIAL REMOTE
CONTROLLER
user manual
imagine the possibilities
Thank you for purchasing this Samsung product.
To receive more complete service,
please register your product at
www.samsungsecurity.com
English 1
Краткое содержание страницы № 2
Safety information 9 CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN 1 CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED C SERVICE PERSONNEL. 1 This symbol indicates that dangerous voltage consisting a risk of 2 electric shock is present within this unit. This exclamation point symbol is intended to alert the user to 3 the presence of important operating and maintenance (servicing) instructions in the lite
Краткое содержание страницы № 3
ENG Safety information 9. If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.) 10. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock. CAUTION 1. Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive vibr
Краткое содержание страницы № 4
Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. 8. Do not install near any heat sources such as radiators, heat registers, or other apparatus (including amplifi ers) that produce heat. 9. Do not defeat the safety purpose of
Краткое содержание страницы № 5
ENG Contents Introduction Introduction 6 Part names and functions 7 Installation Checking Installation Environment 11 Installation precautions 11 Connection & Control To Control the camera coaxial communications 12 To control the camera using RS-485 device via coaxial communications 13 To control the camera using RS-232 device via coaxial communications 14 To control the camera using RS-485 signal output 15 To control the camera using RS-485 signal output via RS-232 communicati
Краткое содержание страницы № 6
Introduction INTRODUCTION P This product is a remote controller for Samsung’s CCTV cameras of New-generation ❖ DSP, via coaxial cable not requiring additional control wirings. ❖ Features � Long-distance remote control Through RS-485 communication, remote control is possible up to 1.2 kilometers. � Easy Control Easy and simple 5-way keys for controlling the camera. � System’s Expandability It is possible to implement an integrated system by using the system controller (SSC-5000 or similar)
Краткое содержание страницы № 7
7 7 7 6 6 6 ENG 5 5 5 4 4 4 3 3 3 Introduction PART NAMES AND FUNCTIONS ❖ Front Panel POWER STATUS POWER ADDRESS OFF ON (X)100 (X)10 (X)1 CABLE COMPENSATION SL ON ON 1 2 1 2345678 TERMINATION PROTOCOL REMOTE CONTROLLER SCX-RD100 ❶ STATUS LED - Displays the status of the current operation. ❷ POWER LED - When the controller turns on, it will be turn light. ❸ POWER Switch - If you slide it to ON, the controller turns on. ❹ CABLE COMPENSATION Switch - For long distance coaxial communicatio
Краткое содержание страницы № 8
7 7 7 6 6 6 5 5 5 4 4 4 3 3 3 Introduction P ❺ RS-485 TERMINATION & PROTOCOL Setting Switch - You can select to set the RS-485 termination. ❖ - Turn this switch ON, if RS-485 termination is required. ON ON ON 1 2 1 1 2345678 2 3 4 5 6 7 8 TERMINATION PROTOCOL PROTOCOL - For multi-protocol settings, you can set the protocol and baud rate, and selection of COAXIAL/RS-485 or RS-232. ON ON ON 1 1 2 2 1 2345678 TERMINATI TERMINATION ON PROTOCOL - Use pin 1,2,3,4 of the Protocol setting switch to se
Краткое содержание страницы № 9
ENG Introduction PART NAMES AND FUNCTIONS ❖ Rear Panel - AA BATTERY You can use 4 AA-sized batteries for the power. . - The average operation time is 20 hours based on the alkaline battery. (If the battery is discharged, it can cause a distortion of the video signal, or electric interference.) Remove the battery if you do not use the controller for a longer period. Otherwise, it NOTE may cause damage to the controller from a leak of the battery solution. Take caution not to change the spec
Краткое содержание страницы № 10
Introduction ❖ Top C RS-485 DC 12V VIDEO IN RS-232C TX RX OUT IN ❶ USB Port - This terminal is used for updating the product’s fi rmware. ❷ RS-232 Port (9-pin D SUB) - Used to control remotely using RS-232 communication. ❸ RS-485 Port (4-pin) - Used to control remotely using RS-485 communication. ❹ VIDEO IN/OUT Connector (BNC) - VIDEO IN receives coaxial communication from cameras, and VIDEO OUT outputs the video signal. ❺ DC12V Power Connector (2-PIN) - Used for connecting DC12V power sour
Краткое содержание страницы № 11
ENG Installation CHECKING INSTALLATION ENVIRONMENT � Please check the following instructions before installation for your safety. � The way of connecting the main product with external devices (COAXIAL BNC) is very important to build up a proper system. � Do not disassemble the unit; doing so could expose you to dangerous high voltage points. INSTALLATION PRECAUTIONS � Make sure you turn off the product before installation. � Do not put a strong force on or shake the product; otherwise it may
Краткое содержание страницы № 12
Connection & Control TO CONTROL THE CAMERA COAXIAL COMMUNICATIONS T V 1. Connect the product to DC 12V power source or insert 4 AA-sized 1 batteries into the battery compartment. 2. Set the protocol switch 7 to ON. 2 3. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera 3 directly. – For proper data communication, the unit and AI camera should be connected directly. (If you connect a DVR or keyboard in the middle of the main unit and AI camera, bidirectional communication will
Краткое содержание страницы № 13
ENG Connection & Control S TO CONTROL THE CAMERA USING RS-485 DEVICE VIA COAXIAL COMMUNICATIONS 1. Connect the product to DC 12V power source or insert 4 AA-sized batteries into the battery compartment. 2. Set the protocol switch 7 to ON. 3. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera directly. – For proper data communication, the unit and AI camera should be connected directly. (If you connect a DVR or keyboard in the middle of the main unit and AI camera, bidirectiona
Краткое содержание страницы № 14
Connection & Control TO CONTROL THE CAMERA USING RS-232 DEVICE T VIA COAXIAL COMMUNICATIONS O 1. Connect the product to DC 12V power source or insert 4 AA-sized 1 batteries into the battery compartment. 2. Set the protocol switches 7 and 8 to ON. 2 3. Connect the VIDEO IN of the unit and VIDEO OUT of the AI Camera 3 directly. 4 – For proper data communication, the unit and AI camera should be connected directly. (If you connect a DVR or keyboard in the middle of the main unit and AI camera, 5
Краткое содержание страницы № 15
ENG Connection & Control TO CONTROL THE CAMERA USING RS-485 SIGNAL OUTPUT 1. Connect the product to DC 12V power source or insert 4 AA-sized batteries into the battery compartment. 2. Set the protocol switches 7 and 8 to OFF. 3. Connect the RX(+/-) of the unit to the RS-485 (+/-) port of the camera. 4. Match the camera’s address, baud rate, and protocol to the same to those of the unit. 5. Now you can control the camera by using the menus. ❖ You can use the menu as following : – Press and hol
Краткое содержание страницы № 16
Connection & Control TO CONTROL THE CAMERA USING RS-485 SIGNAL S OUTPUT VIA RS-232 COMMUNICATIONS ❖ 1. Connect the product to DC 12V power source or insert 4 AA-sized batteries into the battery compartment. 2. Set the protocol switch 8 to ON. N 3. Connect the RX(+/-) of the unit to the RS-485(+/-) port of the camera. 4. Match the camera’s address, baud rate, and protocol to the same to those of the unit. ❖ – RS-232 can be controlled using the Samsung protocol alone. 5. Connect the RS-232 devic
Краткое содержание страницы № 17
ENG Connection & Control SWITCH SETTING TABLE ❖ Use a combination of pin 1,2,3,4 of the Protocol setting switch to select a protocol. ON ON ON 1 2 1 1 234 2345678 HALF : half-duplex TERMINATION PROTOCOL FULL : full-duplex Protocol Setting Switch (0 : , 1 : ) Protocol HALF/ Pin 1 Pin 2 Pin 3 Pin 4 0 0 0 0 SAMSUNG HALF 1 0 0 0 SAMSUNG FULL 1 1 0 0 PANASONIC HALF 0 0 1 0 PANASONIC FULL 1 1 1 0 PHILIPS HALF 1 0 0 1 KALATEL HALF 0 1 0 1 ERNA HALF 1 1 0 1 DIAMOND HALF 0 0 1 1 VCL TP HALF By defau
Краткое содержание страницы № 18
Connection & Control – See the following table to set the baud rate. ON ON 1 2 1 2345678 56 TERMINATION PROTOCOL 1. SAMSUNG BAUD RATE PIN 5 PIN 6 38400 BPS OFF OFF 19200 BPS ON OFF 9600 BPS OFF ON 4800 BPS ON ON 2. PHILIPS BAUD RATE PIN 5 PIN 6 38400 BPS OFF OFF 9600 BPS ON OFF 3. PANASONIC BAUD RATE PIN 5 PIN 6 19200 BPS OFF OFF 9600 BPS ON OFF 4800 BPS OFF ON 4. DIAMOND, VCL TP BAUD RATE PIN 5 PIN 6 9600 BPS OFF ON Only supports 9600 bps 18 – COAXIAL REMOTE CONTROLLER
Краткое содержание страницы № 19
ENG Connection & Control 5. ERNA BAUD RATE PIN 5 PIN 6 2400 BPS ON ON Only supports 2400 bps 6. KALATEL BAUD RATE PIN 5 PIN 6 9600 BPS OFF ON 4800 BPS ON ON English 19
Краткое содержание страницы № 20
Specifi cations SPECIFICATIONS D Item Description Communication Method COAXIAL INTERFACE COAXIAL Range Max. 500m (with 5C-HFBT cable) Connector Type D-SUB 9P Port 1 Port RS-232 4800/9600/19200/38400bps BAUD RATE (Only Samsung protocol supported) Connector Type 4P Terminal Type Port 1 Port RS-485 2400/4800/9600/19200/38400bps BAUD RATE (Supports each protocol) USB PORT(USB2.0) S/W PROGRAM UPLOAD Composite Video 1.0Vp-p, 75ohm, VIDEO IN/OUT Cable Compensation out (Select:S/L) Operating Temp. -10