Краткое содержание страницы № 1
®
USB Only
Intraoral Digital Video
Camera System
Part Number A5500
Operator’s Manual
Краткое содержание страницы № 2
FOREWORD Air Techniques and its ALLPRO Imaging division have prepared this document as ® a guide to the proper use of the Acclaim USB Only Intraoral Digital Video Camera System. References in this manual to Air Techniques includes its division ALLPRO Imaging. Refer to the following companion documents as necessary: Document Part Number Acclaim Handpiece Instruction Sheet A5537 TABLE OF CONTENTS P Pa ag ge e C Co on ng gr ra attu ulla attiio on ns s . . . . . . . . . . . . . . . . . . . . . . .
Краткое содержание страницы № 3
CONGRATULATIONS ® Congratulations on your purchase of the Acclaim USB Only Intraoral Digital Video Camera System, the latest camera in the dental video imaging product line from Air Techniques, a leading manufacturer of dental and veterinary equipment since 1962. The Acclaim USB Only Camera System design offers the flexible benefits of USB Plug-N-Play technology that is easily integrated into any practice. The very light- weight one-piece toothbrush-size Acclaim Camera Handpiece is an extremely
Краткое содержание страницы № 4
SAFETY NOTICE GENERAL This equipment has been designed to minimize exposure of personnel to hazards. While the Acclaim System is designed for safe operation, certain precautions must be observed. Use of the Acclaim System not in conformance with the instructions specified in this manual may result in permanent failure of the unit. KNOWLEDGE OF WARNINGS AND CAUTIONS Users must exercise every precaution to ensure personnel safety, and be familiar with the warnings and cautions presented throughou
Краткое содержание страницы № 5
SAFETY NOTICE Use of Accessory Equipment. The use of ACCESSORY equipment not complying with the equivalent safety requirements of this equipment may lead to a reduced level of safety of the resulting system. Consideration relating to the choice shall include: Use of the accessory in the PATIENT VICINITY Evidence that the safety certification of the ACCESSORY has been performed in accordance to the appropriate IEC 60601-1 and/or IEC 60601-1-1 harmonized national standard. Use of ACCESSORIES or ca
Краткое содержание страницы № 6
KEY PARTS IDENTIFICATION The Acclaim System is comprised of a Camera Handpiece and USB Umbilical. Each is boxed separately along with associated accessories and is available individually by their selling numbers A5520 and A5550 respectively. When shipped together as a complete Acclaim System, the sperate boxes are packed in a single box as selling number A5500. The following lists the components included with the Acclaim System. A5520 Camera Handpiece box includes: IItte em m Q Qtty y Camera
Краткое содержание страницы № 7
COMPONENT DESCRIPTION The Acclaim System is an intraoral camera system designed for dental and veterinary applications that consists of the Camera Handpiece, Camera Handpiece Holder and the USB Umbilical as described below. NOTE: Air Techniques’ VISIX Imaging Software is fully compatible with the Acclaim System. Contact your authorized Air Techniques dealer to acquire VISIX. Camera Handpiece - The Camera Handpiece is extremely lightweight with a high resolution, high sensitivity, auto-exposure
Краткое содержание страницы № 8
PRE-INSTALLATION INFORMATION IMPORTANT: When operating the Acclaim System connected to the USB port on a Computer System, the computer must be loaded with Air Techniques Authorized DirectX 9 compliant streaming video software application and authorized imaging software such as VISIX. Contact your dealer for available Computer Systems and software options. NOTE: VISIX Imaging Software is fully compatible with Acclaim Systems. Minimum Computer System Requirements - The Computer System (lap- top o
Краткое содержание страницы № 9
HANDPIECE KEYPAD BUTTON FUNCTIONS 1 2 3 Acclaim Camera Handpiece A5520 Keypad Buttons - Each keypad button provides the Acclaim Camera Handpiece fingertip control over the PC streaming video capture software via the USB Umbilical. The specific functions performed by the keypad buttons depend on a software installation that supports the 2-button handpiece. Typical keypad actions provided below. NOTE: Simultaneously depressing both keypad buttons for approximately 3 seconds deactivates the Camera
Краткое содержание страницы № 10
SYSTEM SETUP Installing the Acclaim System is as simple as making the necessary connections of the USB Umbilical between a PC loaded with an Air Techniques Authorized DirectX 9 compliant user-supplied streaming video software application such as VISIX and the Camera Handpiece. Perform the following procedures to set up the Acclaim System. Notes: Authorized Imaging Software, such as VISIX, supplied by the dealer or other company, must be installed on the computer in order to operate the Acclaim
Краткое содержание страницы № 11
SYSTEM SETUP USB Interface Connection - Connect the USB Type A connector side of the USB Umbilical to any available USB 2.0 High Speed port on the user supplied Computer System. Always make sure to u us se e tth he e s sa am me e U US SB B p po or rtt whenever recon- nection of the USB cable is necessary. Computer USB Port USB Type A Connector USB Umbilical U US SB B IIn ntte er rffa ac ce e C Co on nn ne ec cttiio on n Use care when adhering the handpiece holder to selected surface. The
Краткое содержание страницы № 12
INFECTION CONTROL SHEATH The Acclaim System should be used with an infection control sheath covering the handpiece. Make sure to use a new disposable infection control sheath for each patient. The infection control sheath must be used for only one patient and disposed of properly in accordance with 2 local code. NOTE: For optimum image clarity, the optically clear section of the sheath must be aligned with the camera lens by facing the camera/light source section of the handpiece down toward the
Краткое содержание страницы № 13
SYSTEM OPERATION Verify that the video capture software is running and correctly configured. The Acclaim System is operated connected directly to a computer system running various PC USB streaming video capture software applications such as VISIX. The camera provides the image/video source while the computer and associated software are used to display and save the resultant images. Perform the following procedures to operate the Acclaim System when correctly connected to a computer. 1. Remove t
Краткое содержание страницы № 14
CAMERA PORTABILITY Do not twist or turn the Handpiece Cable connector. The connector is keyed and mates straight on with Camera Handpiece connector. Whether detaching just the Camera Handpiece from the USB Umbilical and using with additional Acclaim USB Umbilicals installed on other computers or bringing the complete system (handpiece and umbilical), the Acclaim System is easily shared among patient operatories. Refer to the corresponding illustrations and perform the following when trans- port
Краткое содержание страницы № 15
FINAL SYSTEM CHECK USB Video Diagnostic - If live video is not displayed on the PC monitor of the Acclaim System when the streaming video capture software application is running, there could be a problem with the settings in the software application or with the camera system. Perform the USB Video Diagnostic procedure to check the following: The camera and the USB 2.0 interface control module of the USB Umbilical are working correctly. The USB Umbilical is correctly connected between the cam
Краткое содержание страницы № 16
MAINTENANCE INSPECTION AND CLEANING Perform the following inspection and cleaning procedures periodically as a preventive maintenance measure to keep the Acclaim System in optimal condition resulting in trouble-free operation producing crisp, clear images. Do not attempt any internal service of Acclaim System components. Contact your local authorized air techniques dealer for service. Failure to heed this warning may result in equipment damage and voiding the warranty. Inspection - Routinely in
Краткое содержание страницы № 17
SPECIFICATIONS Power Consumption: USB powered device using less than 500 mA. No external power supply is required. Video Outputs: High Speed USB 2.0 Video Sensor: ¼ Inch CCD Format: NTSC Pixels: 768 H X 494 V Resolution: 470 TV lines Signal to Noise Ratio: > 50 dB Exposure Control: Automatic Illumination: Ultra-bright white LED lamps Image: Normal, not mirrored Viewing Angle: 50 Degrees horizontal Operating Temperature: 10º to 40º C Storage Temperature: 0º to 70º C Humidity: 10 to 90% non-conden
Краткое содержание страницы № 18
PHYSICAL CHARACTERISTICS Dimensions Length Width Height Weight Handpiece A5520: 8.3 inches 1.0 inches 0.9 inches 2.1 oz. (21.08 cm) (2.54 cm) (2.29 cm) (59 g) USB Umbilical A5550: 13.5 feet 7.8 ounces (4.11 m) (221.12 g) USB 2.0 Interface 5.9 inches 1.9 inches 0.9 inches Control Module (15.0 cm) (4.8 cm) (2.3 cm) USB 2.0 Cable 4 feet (1.22 m) Control Umbilical 9 feet (2.74 m) ACCESSORIES The following lists the ordering number and description for accessory compo- nents available to maintain and
Краткое содержание страницы № 19
VISIX IMAGING SOFTWARE Consider VISIX, our new comprehensive digital imaging software application, providing seamless integration with our digital imaging suite; the Accent CCD Intraoral Sensor, ScanX PSP Systems and Acclaim Intraoral Cameras. Key Features. Easy to learn. Simple to use. Acquire, mount, view and store images with just a few mouse clicks. Customize images to personal preferences with our simple Set-Up 1-2-3 tool. Exposure - Our Stop Light Exposure System is a unique
Краткое содержание страницы № 20
Air Techniques and ALLPRO Imaging are leading manufacturers of fine dental, medical and veterinary equipment from air and vacuum systems and X-ray film processors, to an impressive line of new products incorporating the most recent technological advances. These new products, vital components of the innovative professional practice, include intraoral cameras, digital imaging systems, which utilizes phosphor plate technology and, most recently, an intraoral digital X-ray system using sensor techno