The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccuracies that may be contained in this document, makes no commitment to update or to keep current the information in this manual, or to notify any person or organization of the updates. Please Note: For the most up-to-date version of this manual, please see our web site at www.supermicro.com. SUPERMICRO COMPUTER reserves the right to make chang
Краткое содержание страницы № 3
Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the AS1041M-T2/1041M-82. Installation and maintainance should be performed by experienced technicians only. The AS1041M-T2/1041M-82 is a high-end server based on the SC818TQ+-1000/ SC818S+-1000 1U rackmount chassis and the H8QME-2+/H8QM8-2+, a quad processor serverboard that supports AMD Socket F type processors and up to
Краткое содержание страницы № 4
AS1041M-T2/1041M-82 User's Manual Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the AS1041M-T2/1041M-82. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the H8QME-2+/H8QM8-2+ serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors
Краткое содержание страницы № 5
Preface Notes v
Краткое содержание страницы № 6
AS1041M-T2/1041M-82 User's Manual Table of Contents Preface About This Manual ...................................................................................................... iii Manual Organization ................................................................................................... iii Chapter 1: Introduction 1-1 Overview ......................................................................................................... 1-1 1-2 Serverboard Features ...............
Краткое содержание страницы № 7
Table of Contents Chapter 4: System Safety 4-1 Electrical Safety Precautions .......................................................................... 4-1 4-2 General Safety Precautions ........................................................................... 4-2 4-3 ESD Precautions ............................................................................................ 4-3 4-4 Operating Precautions ....................................................................................
Краткое содержание страницы № 8
AS1041M-T2/1041M-82 User's Manual Overheat LED ........................................................................................ 5-16 Wake-On-LAN ........................................................................................ 5-17 Wake-On-Ring ........................................................................................ 5-17 SMB Power Header ............................................................................... 5-17 3rd Power Supply Alarm Reset Header ...
Краткое содержание страницы № 9
Table of Contents Chapter 7: BIOS 7-1 Introduction ..................................................................................................... 7-1 7-2 Main Menu ...................................................................................................... 7-2 7-3 Advanced Settings Menu ............................................................................... 7-2 7-4 Boot Menu ............................................................................................
Краткое содержание страницы № 10
AS1041M-T2/1041M-82 User's Manual Notes x
Краткое содержание страницы № 11
Chapter 1: Introduction Chapter 1 Introduction 1-1 Overview The AS1041M-T2/1041M-82 is a high-end server comprised of two main subsys- tems: the SC818TQ+-1000/SC818S+-1000 1U server chassis and the H8QME-2+/ H8QM8-2+ quad processor serverboard. Please refer to our web site for information on operating systems that have been certifi ed for use with the 1041M-T2/1041M-82 (www.supermicro.com/aplus). In addition to the serverboard and chassis, various hardware components have be
Краткое содержание страницы № 12
AS1041M-T2/1041M-82 User's Manual 1-2 Serverboard Features At the heart of the 1041M-T2/1041M-82 lies the H8QME-2+/H8QM8-2+, a quad processor serverboard based on the nVidia MCP55 Pro and AMD-8132 chipsets. Below are the main features of the H8QME-2+/H8QM8-2+ (see Figure 1-1 for a block diagram of the chipset). Processors The H8QME-2+/H8QM8-2+ supports dual or quad AMD Socket F type processors. Please refer to the serverboard description pages on our web site for a complete listing of s
Краткое содержание страницы № 13
Chapter 1: Introduction Onboard Controllers/Ports One fl oppy drive controller and one onboard ATA/100 controller are provided to support up to two IDE hard drives or ATAPI devices. The color-coded I/O ports include one COM port, a VGA (monitor) port, two USB 2.0 ports, PS/2 mouse and keyboard ports and two gigabit Ethernet ports. ATI Graphics Controller The H8QME-2+/H8QM8-2+ features an integrated ATI video controller based on the ES1000 graphics chip. The ES1000 was designed specifi cal
Краткое содержание страницы № 14
AS1041M-T2/1041M-82 User's Manual PCI Expansion Slots One standard size PCI-E add-on card may be used with the SC818TQ+-1000/ SC818S+-1000 chassis. See section 5-6 for details. Front Control Panel The SC818TQ+-1000/SC818S+-1000's control panel provides you with system monitoring and control. LEDs indicate system power, HDD activity, network activity (2) and overheat/fan failure. A main power button and system reset button is also included. I/O Backplane The SC818TQ+-1000/SC818S+-100
Краткое содержание страницы № 15
Chapter 1: Introduction Figure 1-1. nVidia MCP55 Pro/AMD-8132 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. DDR2-667/533/400 DDR2-667/533/400 AMD Socket F Type AMD Socket F Type DIMMC 2A DIMMB 1B Processor (CPU3) Processor (CPU4) DIMMC 2 B DIMMB 1A DIMMC 1 A DIMMB 2B DIMMC 1B DIMMB 2A 16 x 16 HT link (1 GHz) AMD Socket F Type AMD Socket F Type DIMMD 1B DIMMA 2A Processor (CPU2) Processor (CPU1) DIMMD 1 A DIMMA 2B DIMMD 2 B DIMMA 1A
Краткое содержание страницы № 16
AS1041M-T2/1041M-82 User's Manual 1-4 Contacting Supermicro Headquarters Address: SuperMicro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: SuperMicro Computer B.V. Het Sterrenbeeld 28, 5215 ML '
Краткое содержание страницы № 17
Chapter 2: Server Installation Chapter 2 Server Installation 2-1 Overview This chapter provides a quick setup checklist to get your 1041M-T2/1041M-82 up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled. If your system is not already fully integrated with a serverboard, pro
Краткое содержание страницы № 18
AS1041M-T2/1041M-82 User's Manual Choosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches). - Leave approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing. - This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). Warnings and Precautions! ! ! Rack Precautions - Ensure that
Краткое содержание страницы № 19
Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra). Reduced Airfl ow Equipment should be mounted into a rack so that the
Краткое содержание страницы № 20
AS1041M-T2/1041M-82 User's Manual 2-4 Installing the System into a Rack This section provides information on installing the 1041M-T2/1041M-82 into a rack unit with the rack rails provided. If the system has already been mounted into a rack, you can skip ahead to Sections 2-5 and 2-6. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.