Краткое содержание страницы № 1
® ®
Polycom RMX 4000
Hardware Guide
Version 6.0 | August 2010 | DOC2559A
Краткое содержание страницы № 2
Trademark Information Polycom®, the Polycom “Triangles” logo, and the names and marks associated with Polycom’s products are trademarks and/or service marks of Polycom, Inc., and are registered and/or common-law marks in the United States and various other countries. All other trademarks are the property of their respective owners. Patent Information The accompanying product is protected by one or more U.S. and foreign patents and/or pending patent applications held by Polycom, Inc. © 2010
Краткое содержание страницы № 3
CE MARK R&RTTE Directive Česky [Czech]: Polycom (UK) Ltd tímto prohlašuje, že tento RMX 4000 je ve shod ě se základními požadavky a dalšími p říslušnými ustanoveními sm ěrnice 1999/5/ES. Dansk [Danish]: Undertegnede Polycom (UK) Ltd erklærer herved, at følgende udstyr RMX 4000 overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/ EF. Deutsch [German]: Hiermit erklärt Polycom (UK) Ltd, dass sich das Gerät RMX 4000 in Übereinstimmung mit den grundlegenden Anforderungen und d
Краткое содержание страницы № 4
Polski [Polish]: Niniejszym Polycom (UK) Ltd o świadcza, że RMX 4000 jest zgodne z zasadniczymi wymaganiami oraz innymi stosownymi postanowieniami Dyrektywy 1999/5/WE Português [Portuguese]: Polycom (UK) Ltd declara que este RMX 4000 está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Slovensko [Slovenian]: Polycom (UK) Ltd izjavlja, da je ta RMX 4000 v skladu z bistvenimi zahtevami in ostalimi relevantnimi dolo čili direktive 1999/5/ES. Slovensky [Slovak]
Краткое содержание страницы № 5
Polycom RMX 4000 Hardware Guide Table of Contents Hardware Description . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Main Features .......................................................................................... 1-1 RMX 4000 Specifications ....................................................................... 1-2 RMX 4000 System Capacities ........................................................ 1-3 MPMx Resource Capacities ...................................................
Краткое содержание страницы № 6
Table of Contents ISDN/PSTN Clock Source .................................................. 1-31 RTM LAN ...................................................................................... 1-31 AC Power Entry Module (PEM) ................................................ 1-32 DC Power Rail Module ................................................................ 1-32 Component Slot Allocation ......................................................... 1-32 RMX 4000 LEDs ...........................
Краткое содержание страницы № 7
1 Hardware Description This Hardware Guide provides information on the RMX 4000 and its components. This system utilizes a modular “universal slot” platform, whose components are designed for high performance, capacity and reliance. Main Features The Polycom RMX 4000 offers the following features: •Linux® based • Chassis based on the ATCA standard • Built-in redundancy, hot swappable parts • Physical network and media separation between management and signaling networks, with high speed swi
Краткое содержание страницы № 8
Chapter 1- Hardware Description RMX 4000 Specifications Table 1-1 Polycom RMX 4000 Specifications Physical Height 6U (26.56 cm.) Width 19” (48.26 cm.) Depth 15.74” (40 cm.) Weight Up to 40 Kg. Media Protocols Audio G.711, G. 719, G.722, G.722.1, G.729A, G.723.1, Siren14, Siren 22. Video H.261, H.263, H.264. Network Interfaces IP, ISDN, PSTN and LAN H.323, SIP, PSTN, LAN and ISDN. Power Supply AC Input/ Range, BTU Voltage range:100-240 VAC, 14-7 AMP, 50/60 Hz. BTU output: 5120. DC Input/Range
Краткое содержание страницы № 9
Polycom RMX 4000 Hardware Guide Table 1-1 Polycom RMX 4000 Specifications (Continued) Operating temperature 10°– 40°C (50°– 104°F). Storage temperature -40°– 70°C (40°– 158°F). Relative humidity 15% - 90% no condensing. Operating altitude 60m below sea level, up to 3,000 m (10,000 ft.). Operating ESD 4kV. RMX 4000 System Capacities The following table summarizes the different system capacities. Table 1-2 System Functions and Capacities RMX 4000 System Functions MPM+ Mode MPMx Mode Maximum number
Краткое содержание страницы № 10
Chapter 1- Hardware Description Table 1-2 System Functions and Capacities RMX 4000 System Functions MPM+ Mode MPMx Mode Maximum number of IVR Services 80 80 Maximum number of Recording Links 20 (default) 20 (default) Maximum number of IVR Video Slides 150 150 Maximum number of Log Files (1Mb max.) 8000 8000 Maximum number of CDR Files 4000 4000 Maximum number of Fault Files 1000 1000 Number of Participant alerts Unlimited Unlimited Maximum number of concurrent RMX Web 20 20 Client connections to
Краткое содержание страницы № 11
Polycom RMX 4000 Hardware Guide Table 2 MPMx – Resource Capacity per Card (Continued) Resource Type MPMx - S MPMx - D H.264 CIF/VSW 45 90 SD 30 60 HD720p30 15 30 HD720p60/ 815 HD1080p30 (Symmetrical) MPM+ Resource Capacities Three MPM+ card assemblies are available: MPM+ 80, MPM+ 40 and MPM+ 20 offering various resource capacities for CP conferences. Table 1-1 summarizes the video capacities of the various MPM+ card assemblies. Table 1-1 MPM+ Card Assemblies and Resource Capacities for CP
Краткое содержание страницы № 12
Chapter 1- Hardware Description Table 1-2 MPM+ Resource/Port Capacity Resource Type Maximum Capacity (4 MPM+ Cards) CIF 320 SD30 120 HD720p 80 HD1080p 40 720p VSW 4Mb 160 1080p VSW 4Mb 160 1080p VSW 6Mb 80 RMX memory size is listed in the Administration > System Information properties box. In HD Video Switching conferences, an RMX with four MPM+ cards can support up to 160 participants at HD1080p resolution at bandwidths of up to 4Mbps and 80 participants at HD1080p resolution at bandwidths o
Краткое содержание страницы № 13
Polycom RMX 4000 Hardware Guide • The RMX switches between MPMx and MPM+ Card Configuration Modes when MPM+/MPMx cards are removed or swapped while the system is running. • The switch between Card Configuration Modes occurs during the next restart. • Installing or swapping MPM+/MPMx cards while the system is off will not cause a switch in the Card Configuration Mode when the system is restarted – it will restart in the Card Configuration Mode that was active previous to powering down. 1-7
Краткое содержание страницы № 14
Chapter 1- Hardware Description Safety Requirements This section describes the requirements your site must meet for safe installation and operation of the system. Site Safety Requirements For your protection, please read these safety instructions completely before operating the equipment. • Look carefully for potential hazards in your work area: moist floors, ungrounded power cables, frayed power cords, missing safety grounds and so forth. • Locate the main circuit breaker within the room.
Краткое содержание страницы № 15
Polycom RMX 4000 Hardware Guide General Installation Precautions Attention: The RMX 4000 can weigh up to 40kg when all slots are occupied. Two people are required to lift the MCU out of the box and also when installing it in a rack. • Use a regulating uninterruptable power supply (UPS) to protect the RMX 4000 from power surges and voltage spikes, to keep your MCU operating in case of a power failure. The RMX 4000 requires either two (DC) or three (AC) power supply cables, each connected to a
Краткое содержание страницы № 16
Chapter 1- Hardware Description • Always keep the rack’s trays and card’s slots closed when not servicing, to maintain proper cooling. Installing the RMX 4000 The following procedures have to be performed to install the RMX 4000 in your site: • Unpacking the RMX 4000 • Installing the RMX in a rack or as a standalone • Connecting the RMX 4000 to the power source • Connecting the network (LAN, IP and ISDN) cables to the RMX Unpacking the RMX 4000 To unpack and lift the RMX 4000: 1 When you recei
Краткое содержание страницы № 17
Polycom RMX 4000 Hardware Guide Make sure that boxes contain all the required parts. 4 Remove the boxes and top Stratocell®. 5 Holding the handle on each side, lift the RMX 4000 from the box, and place it on a flat surface or install it in a rack. Remove any packaging material prior to positioning the RMX 4000. Attention: Two people are required to lift the MCU out of the box and when installing it in a rack. 1-11
Краткое содержание страницы № 18
Chapter 1- Hardware Description Installing the RMX in a Rack or as a Standalone Either place the RMX 4000 on a hard, flat surface such as a desktop or mount it on a 19”/23” rack. Standalone RMX 4000 Installation Place the RMX 4000 on a flat surface or desktop. The RMX 4000 must rest on the four feet at the base of the MCU and must be shifted or moved into position using the two handles attached to the front. Rack Mount Preparations • Optional - Depending on the rack installed in your site
Краткое содержание страницы № 19
Polycom RMX 4000 Hardware Guide Placing the RMX 4000 in a 19” Rack 1 When the RMX is to be rack mounted chassis runners must be installed on the rack as shown in Figure 1-2. Two chassis runners are included in the Rack Installation Accessories kit and are attached facing inward from the outside of the 19”/23“rack mount. Figure 1-2 Installing chassis runners and RMX in a rack 2 Mount the RMX on top of the rack brackets using the blades or placing it on a rack mount shelf with runners. 1-13
Краткое содержание страницы № 20
Chapter 1- Hardware Description 3 Fasten the RMX to the rack with 8 screws into the holes provided on the RMX’s front as shown in Figure 1-3. Figure 1-3 RMX 4000 Rack Mount Rack mounting screws must be supplied by the rack’s manufacturer. The airflow of the RMX 4000 is from right to left. Be sure that the areas on the left and right side of the system are clear for proper ventilation. When the unit is installed on a rack, the rack must be properly grounded to the central office ground. The r