Краткое содержание страницы № 1
855-900549-A
Rev. 1
NX7700i/5020M-16
Operation Manual
CAUTION
Before using the product, be sure to read this manual and strictly
adhere to the instructions.
Keep this manual at hand for quick reference as required.
©NEC Corporation 2006
This manual cannot be duplicated or revised without permission from NEC Corp.
The contents of this manual may be changed without prior notice.
NEC Corporation
Краткое содержание страницы № 2
Notes on export This product (including software) may be classified into the cargo (or service) to which the Foreign Exchange and Foreign Trade Control Law is applied. If this is the case, an export permit issued by the Government of Japan is required. If you need materials to help go through the process of applying for an export permit, consult your delivery agent or the nearby NEC branch office. Compliance with the criteria of Voluntary Control Council for Interference by
Краткое содержание страницы № 3
Safety Precautions Before using the product, read this manual carefully to ensure the proper and safe operation of the product. Follow the instructions in this manual to avoid physical injuries and damages to property. Keep this manual at hand for quick reference as required. The cables supplied with this product are designed to be used solely for this product. Do not use them for other purposes. This operation manual uses the following level of notification to ensure the proper and sa
Краткое содержание страницы № 4
WARNING Do not touch the internal components of the equipment Nobody except the maintenance personnel should open the door of the equipment. Do not disassemble, repair or remodel the equipment by yourself. Do not touch the components inside the equipment or peer into the equipment while the maintenance personnel opened the door for service work. Failure to follow the instruction may result in electric shock or injury due to abnormal operation of the equipment. Do not insert foreign ma
Краткое содержание страницы № 5
Handling of the laser product A laser product of Class 1, Subchapter J, Chapter 1 of JIS C6802, EN60825, IEC825 and FDA21CFR, is used for this equipment. Note) Class 1 lasers are defined in JIC6802, EN60825, IEC825 and FDA 21CFR that they are exempt lasers or laser systems that cannot, under normal operating condition, produce a hazard, and the following label is attached to this class of laser product: CLASS 1 LASER PRODUCT PER IEC825 LASER KLASSE 1 NACH IEC825 PRODUCTO LASER DE CLASE 1
Краткое содержание страницы № 6
140 CAUTION:For continued protection against risk of fire, replace only with same type and ratings of fuse. ATTENTION:Pour une protection continue contre l'incendie,remplacer les fusibles par ceux de meme type et de meme amperage. 150 HAZARD AREA:QUALIFIED SERVICE PERSONNEL ONLY DANGER:RESERVE SEULEMENT AU PERSONNEL 163 Install with arrow pointing upwards. Monter de maniere a orienter la fleche vers le haut. 165 CAUTION:HIG
Краткое содержание страницы № 7
243 CAUTION:Disconnect input power before removing this cover. ATTENTION:Couper l'alimentation electrique avant de demonter ce capot. 416 CAUTION: PULL OUT STABILIZER WHEN MAINTAINING. ATTENTION: TIRER LE STABILISIEREN. 417 420 422 vi
Краткое содержание страницы № 8
133-314121-GRP MARKINGS 051 WARNING Do not pull out more than one component at a time as it may cause damege to the rack or allow the rack to tip over. 052 WARNING Always extract and install the stabilizers when pulling out ore unloading components from the rack. Operating on the rack without the stabilizers in place may cause damage to the rack or allow the rack to tip over. 053 DANGER Always install the stabilizers when not bolting to the floor for seismi
Краткое содержание страницы № 9
243-304367-GRP MARKINGS 001 243-306629-GRP MARKINGS 001 002 viii
Краткое содержание страницы № 10
Preface This document explains how to operate the hardware of the base module, the main body of this system. It is recommended that the related documents be read in order to make the best use of the above-mentioned system. Special techniques are necessary for installing and expanding the system. Please consult our sales personnel. Rev. 1, May 2006 Notes: (1) All rights reserved. This document cannot be reprinted or reproduced partly or entirely without permission from NEC Corp. (2)
Краткое содержание страницы № 11
Contents Chapter 1 NX7700i/5020M-16 System Overview .................................................................1-1 1.1. Configuration and Specifications of the Base Module ...............................................1-2 1.2. Expandability.............................................................................................................1-6 1.2.1. Adding Processors...............................................................................................1-6 1.2.2. Expa
Краткое содержание страницы № 12
2.4.6.4. DT (SP Data and Time) ..............................................................................2-37 2.4.6.5. EN (Environmental Information).................................................................2-38 2.4.6.6. FV (Firmware Versions) .............................................................................2-44 2.4.6.7. HC (Hardware Configuration).....................................................................2-45 2.4.6.8. HE (Help)...............................
Краткое содержание страницы № 13
NX7700i/5020M-16 System Overview Chapter 1 NX7700i/5020M-16 System Overview This system is a server that implements the following by using the high performance Intel Itanium2 processor: • High processing capability • Open system using the industry standard architecture • Advanced system management and RAS function • High system expandability with a host of optional products Unit: (mm) (a) Perspective View (Front) (b) P
Краткое содержание страницы № 14
NX7700i/5020M-16 System Overview 1.1. Configuration and Specifications of the Base Module The base module of this system is composed of the following hardware components: − CELL Can install one to four Intel Itanium2 processors. The minimum required memory capacity is 2GB and can be expanded up to 128GB. − I/O MODULE Can contain: Up to 8 PCI cards A DVD-ROM unit A DAT unit Up to 4 HDDs (up to two HDDs when DAT is used) − POWER BAY Can contain to 3 DPSs (AC/DC converter
Краткое содержание страницы № 15
NX7700i/5020M-16 System Overview Front View I/O MODULE POWER BAY FAN BOX DPS Rear View FAN BOX iSP CARD AC SW INLET BOX Figure. Layout of Parts in the Base Module 1-3 855-900549
Краткое содержание страницы № 16
NX7700i/5020M-16 System Overview Table. Base Module Specifications BASE MODULE Cell (Max. 2 cells can be installed in the base module.) CPU Max. No. of processors 8 (Max. 4 processors/cell) Main memory Expansion unit 2GB/4GB/8GB Main memory capacity 2GB to 128GB I/O module (Max. 2 modules can be installed.) Max. No. of PCI slots 16 slots (133MHz) Max. I/O bandwidth 67GB/s One unit can be installed in the I/O module. DVD-ROM unit DVD-ROM/CD-ROM mode One unit can be installed
Краткое содержание страницы № 17
NX7700i/5020M-16 System Overview Table. Base Module Specifications (Cont’d) Main Cabinet Cabinet size/weight Note 2) Width 600mm Height 1265/1620/1975mm Depth Note 1) 1050mm Weight (in max. configuration) 545Kg Power supply Voltage Single-phase, 200 to 240V ±10% Frequency 50/60Hz ±1Hz Power consumption (in max. 13.2kVA configuration) Environmental conditions Temperature Operating +5 °C to +32 °C Storage +5 °C to +45 °C Humidity Operating 20% to 80% (no con
Краткое содержание страницы № 18
NX7700i/5020M-16 System Overview 1.2. Expandability This section explains the expandability of this system and available configurations. Contact the maintenance personnel of NEC to replace or CAUTION upgrade the system. 1.2.1. Adding Processors At least one processor is required for the base module. Using the CPU expansion feature, the Itanium2 processor can be added one by one. Up to four processors can be installed for each cell. To install more than four processors, the cell mus
Краткое содержание страницы № 19
NX7700i/5020M-16 System Overview BASE MODULE The minimum 2GB memory can be expanded up to 64GB for each cell. Itanium2 SP Console (Standard) CELL RS232C(Console) Server management Ethernet cable LAN interface 10/100Base - TX DVD-ROM UNIT N E C DAT UNIT I/O MODULE POWER BAY 0 Expansion POWER BAY * The expansion power bay is POWER BAY 1 mounted only when the power is supplied from two systems or 100VAC.
Краткое содержание страницы № 20