Краткое содержание страницы № 1
HP ProLiant DL580 Generation 3 Server
Maintenance and Service Guide
May 2006 (Sixth Edition)
Part Number 379041-006
Краткое содержание страницы № 2
© Copyright 2005, 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft, Windows, and Windows NT are U.S. registered trad
Краткое содержание страницы № 3
Contents Illustrated parts catalog ................................................................................................................. 6 Customer self repair................................................................................................................................... 6 Mechanical components............................................................................................................................. 6 System components ......................
Краткое содержание страницы № 4
Advanced ECC memory ................................................................................................................. 51 Online spare memory .................................................................................................................... 52 Hot-plug mirrored memory .............................................................................................................. 53 Hot-plug RAID memory ..........................................................
Краткое содержание страницы № 5
RILOE II cabling ...................................................................................................................................... 90 Hot-plug SCSI drive cabling...................................................................................................................... 91 SCSI simplex mode........................................................................................................................ 92 SCSI duplex mode..................................
Краткое содержание страницы № 6
Illustrated parts catalog In this section Customer self repair ................................................................................................................................. 6 Mechanical components ........................................................................................................................... 6 System components .................................................................................................................................. 8
Краткое содержание страницы № 7
Item Description Original Modified Original spare Modified Customer assembly part assembly part number spare part self repair number part number number — Hardware kit, ProLiant — — 385642-001 — Yes DL580 G3 Server * 1 a) Blank, power 366450-002 — — — Yes supply 2 b) Blank, 377569-001 — — — Yes CD/DVD/diskette 3 c) Blank, memory 374278-001 — — — Yes board 4 Bezel, ProLiant DL580 367600-001 — 376481-001 — Yes G3 Server 5 Cover, top, ProLiant 367572-001 — 376480-001 — Yes DL580
Краткое содержание страницы № 8
System components Item Description Original Modified Original Modified Customer self assembly part assembly part spare part spare part repair number number number number — System — — — — — components 1 Power supply, 337867- 337867-501 364360- 406421-001 Yes 910–1300 W 001‡ See 001‡ See requirement requirement 2 System cage — — — — — 3 Fan 120 mm, hot- 364517-001 — 374552-001 — Yes plug — Boards — — — — — 4 PCI-X Hot Plug 011077- 011077-501 230981- 411796-001 Yes switch 001
Краткое содержание страницы № 9
Item Description Original Modified Original Modified Customer self assembly part assembly part spare part spare part repair number number number number 8 Media board 012207- 012207-501 376477- 416422-001 Yes (CD/DVD/diskette) 001‡ See 001‡ See requirement requirement 9 Power backplane, 012110- 012110-501 376476- 411795-001 No ProLiant DL580 001‡ See 001‡ See G3 Server * requirement requirement 10 Processor module 012095- 012095-501 376469- 412325-001 Yes assembly, ProLiant 001‡ See 0
Краткое содержание страницы № 10
Item Description Original Modified Original Modified Customer self assembly part assembly part spare part spare part repair number number number number — g) 72-GB SAS 375696-002 — 376597-001 — Yes drive, 10,000 rpm * — h) 36-GB SAS 375696-001 — 376596-001 — Yes drive, 10,000 rpm * — i) 60-GB SATA 390158-001 — 382264-001 — Yes drive, 5,400 rpm * — Memory — — — — — 17 DIMM, PC2-3200, — — — — — DDR2 — a) 512 MB * 345112- 345112-851 359241- 413384-001 Yes 051‡ See 001‡ See require
Краткое содержание страницы № 11
Item Description Original Modified Original Modified Customer self assembly part assembly part spare part spare part repair number number number number — g) Intel® 3.00- 399755-001 — 399955-001 — Yes GHz Xeon™ 2 MBx2 dual core* 19 Processor blanks 392523-001 — 406056-001 — Yes (two) — Cables — — — — — 20 Cable kit, data, — — 376478-001— Yes ProLiant DL580 G3 Server * — a) Cable 346187-001 — — — Yes assembly, USB — b) Cable 367602-001 — — — Yes assembly, power switch — c) Cable
Краткое содержание страницы № 12
Item Description Original Modified Original Modified Customer self assembly part assembly part spare part spare part repair number number number number 30 SAS array 012335-001 — 370855-001 — Yes controller board * 31 SAS array cache 011773-002 — 309522-001 — Yes board (with battery) * 32 SAS/SATA hard 376383-001 — 392613-001 — Yes drive blank * — Miscellaneous — — — — — 33 Battery, 3V, 166899-001 — 153009-001 — Yes Lithium * 34 Power cord, AC 287485-002 — 391097-001 — Yes line, C
Краткое содержание страницы № 13
Removal and replacement procedures In this section Required tools........................................................................................................................................ 13 Safety considerations.............................................................................................................................. 14 Preparation procedures....................................................................................................................
Краткое содержание страницы № 14
• Flathead screwdriver • Diagnostics Utility Safety considerations Before performing service procedures, review all the safety information. Preventing electrostatic discharge To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the d
Краткое содержание страницы № 15
• Power down the server (on page 16). If you must remove a server from a rack or a non-hot-plug component from a server, power down the server. • Remove the server from the rack (on page 16). If the rack environment, cabling configuration, or the server location in the rack makes it difficult to service the unit, remove the server from the rack. • Remove the access panel ("Removing the access panel" on page 17). If you are servicing internal components, remove the access panel. • Remov
Краткое содержание страницы № 16
WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately stabilized before extending a component from the rack. WARNING: To reduce the risk of personal injury, be careful when pressing the server rail-release latches and sliding the server into the rack. The sliding rails could pinch your fingers. 3. After performing the installation or maintenance procedure, slide the server back into the rack by pressing the server rail-release latch
Краткое содержание страницы № 17
Removing the access panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage. IMPORTANT: When removing the access panel to view QuickFind diagnostic LEDs ("QuickFind diagnostic d
Краткое содержание страницы № 18
8. Remove all power supplies ("Removing a redundant hot-plug power supply" on page 48). 9. Loosen the thumbscrews, and lift the system cage from the server. NOTE: The T-15 Torx screwdriver can be used to loosen the thumbscrews. The T-15 Torx screwdriver is shipped with the server and can be located on the rear panel ("Rear panel components" on page 73). Removing the front bezel 1. Power down the server (on page 16). 2. Extend the server from the rack ("Extending the server from th
Краткое содержание страницы № 19
6. Slide the bezel to the right, and detach the bezel from the server. To replace the component, reverse the removal procedure. Removing a media drive blank 1. Power down the server (on page 16). 2. Use the T-15 Torx screwdriver to eject the drive blank, and pull the drive blank out of the server. NOTE: The T-15 Torx screwdriver is shipped with the server and can be located on the rear panel ("Rear panel components" on page 73). To replace the component, reverse the removal pro
Краткое содержание страницы № 20
1. Power down the server (on page 16). 2. Use the T-15 Torx screwdriver to eject the drive, and pull the drive out of the server. NOTE: The T-15 Torx screwdriver is shipped with the server and can be located on the rear panel ("Rear panel components" on page 73). To replace the component, reverse the removal procedure. Removing the processor module NOTE: Refer the section "Processor module LEDs (on page 72)" for information on the current processor and PPM status. 1. Power do