SB26/SB2600
Discreet
Surveillance
Domes
Installation/
Operation Manual
C1402M-B (2/98)
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
Краткое содержание страницы № 2
CONTENTS Section Page 1.0 GENERAL ..................................................................................................5 1.1 IMPORTANT SAFEGUARDS AND WARNINGS ............................... 5 2.0 DESCRIPTION ..........................................................................................6 2.1 Models ................................................................................................7 3.0 INSTALLATION ...........................................................
Краткое содержание страницы № 3
LIST OF ILLUSTRATIONS Figure Page 1 SB2600 Wiring Diagram .................................................................... 9 2 SB2600-SL Wiring Diagram ..............................................................10 3 SB2600SL-PP Wiring Diagram .........................................................11 4 SB2600-PP Wiring Diagram .............................................................12 5 Fixed Ceiling Mounting ..................................................................... 13 6
Краткое содержание страницы № 4
(This page intentionally left blank.) 4 Pelco Manual C1402M-B (2/98)
Краткое содержание страницы № 5
1.0 GENERAL 1.1 IMPORTANT SAFEGUARDS AND WARNINGS Prior to installation and use of this product, the following WARNINGS should be CAUTION: This device observed. is designed to operate at 24 volts AC power. Input 1. Installation and servicing should only be done by Qualified Service Personnel voltage must not exceed and conform to all Local codes. 28 volts or drop below 22 volts or else DAMAGE TO 2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or THE MOTORS WILL 6
Краткое содержание страницы № 6
2.0 DESCRIPTION The SB26 is a discreet surveillance, low profile, hemisphere dome for CCD type cameras designed for ease of installation, relocation, and service in fixed ceilings or standard 2' x 2' (.61 m x .61 m) or 2' x 4' (.61 m x 1.22 m) false ceiling tiles. The black opaque lower dome effectively conceals the camera while providing an incon- spicuous viewing window. The dome is attached to the drive to keep the viewing window and camera aligned. To simplify installation even further, Pel
Краткое содержание страницы № 7
2.1 MODELS NOTE: All of the models are listed SB26 Drop ceiling discreet surveillance enclosure with black opaque lower dome with 1 f-stop light loss and all aluminum back box by Underwriters Laboratories Inc. which mounts above the ceiling. (Camera mount supplied.) (UL) SB26-1 Same as SB26 except supplied with clear viewing slot for virtually zero light loss. (UL) SB26-2 Same as SB26 except supplied with mirrored lower dome with 2 f-stop light loss. (UL) SB2600 This system package includes th
Краткое содержание страницы № 8
3.0 INSTALLATION Save the shipping box and any inserts in case the unit must be returned for credit or repair. 3.1 CONDUCTOR AND CABLE REQUIREMENTS (ALL MODELS EXCEPT SB26) A minimum of 12 conductors plus coax is required, which includes common re- quirements for motorized zoom lens and camera AC power. Non-PP Models NOTE: The following are cable 12 Conductor 13 Conductor* requirements. A relay box (RB24) is 20 Awg 130 ft (39.62 m) 185 ft (56.38 m) available to extend the operating dis- 18 Awg
Краткое содержание страницы № 9
Figure 1. SB2600 Wiring Diagram Pelco Manual C1402M-B (2/98) 9
Краткое содержание страницы № 10
Figure 2. SB2600-SL Wiring Diagram 10 Pelco Manual C1402M-B (2/98)
Краткое содержание страницы № 11
Figure 3. SB2600SL-PP Wiring Diagram Pelco Manual C1402M-B (2/98) 11
Краткое содержание страницы № 12
Figure 4. SB2600-PP Wiring Diagram 12 Pelco Manual C1402M-B (2/98)
Краткое содержание страницы № 13
3.3 MOUNTING INSTRUCTIONS Handle the lower dome with care so as not to scratch or get fingerprints on the viewing window. Determine the type of mounting desired. The enclosure can be mounted in a fixed ceiling, or completely replace a standard 2' x 2' (.61 m x .61 m) ceiling tile. 3.3.1 Fixed Ceiling Mounting To mount the enclosure directly into a fixed ceiling, perform the following steps (refer to Figure 5): 1. Determine the location and direction of the enclosure. Ideally, the enclosure cut
Краткое содержание страницы № 14
3.3.2 Dropped Ceiling, Tile Replacement Mounting To mount the enclosure into a dropped ceiling grid, perform the following steps (refer to Figure 6): 1. Determine the location for mounting the enclosure and remove the appropri- IMPORTANT: When installing the ate ceiling tile. enclosure in a 2' x 4' (.61 m x 1.22 m) ceiling grid, cut the ceiling tile in half 2. Remove trim ring and dome. Angle the back box through the grid opening and and install an additional “T” bar for set the box into the gr
Краткое содержание страницы № 15
3.3.3 Camera/Lens Installation Install the camera/lens that you have selected for use with the SB2600 Series dome as follows: 1. Loosen the 1/4-20 lens support fastener and slide lens support down (see NOTE: Remove “shipping Figure 8). bracket” at this time. Refer to Fig- ure 14, item 65. 2. Place camera/lens atop the tilt table and thread the provided 1/4-20 x 1/2-inch fastener through the tilt table into the camera (see Figure 8). Snug the fastener at this time to allow for camera/lens repos
Краткое содержание страницы № 16
3.4 CONNECTOR ASSEMBLY Assemble the connector parts according to the instructions below. Detail B, below, reflects the pin arrangement specific to all SB26/SB2600 Series. Refer to Figure 10 during assembly. For best results use an AMP style crimper when making the wire to pin connection. The instructions that follow apply to all AMP style connectors regardless of pin size or pin number. 1. Slide the connector clamp assembly over the conductor cable. If the diameter of the conductor cable is suc
Краткое содержание страницы № 17
3.5 J-BOX INSTALLATION For installations requiring full plenum rating, perform the following step: Installations Requiring Conduit When conduit must be run to the enclosure back box: 1. Attach the provided J-box to the top of the enclosure back box as shown in Figure 11 using the supplied 6-32 screws. 2. Remove one of the knockouts from the J-box and attach the conduit to the J-box (hardware not supplied). 3. Run the cabling through to the conduit. 4. Assemble the connector onto the end of the
Краткое содержание страницы № 18
Figure 11. Attachment of J-Box to Back Box for Plenum Applications 18 Pelco Manual C1402M-B (2/98)
Краткое содержание страницы № 19
3.6 ADJUSTMENTS CAUTION: Do not at- To adjust the pan limits, perform the following steps. Refer to Figure 12 for limit stop locations. Factory pan limits are set at 0-355°, tilt limits are set at 0-90° (horizontal tempt to adjust limit stops to vertical). when the pan/tilt is in op- eration. Damage to the To adjust limit stops, perform the following steps: equipment can result. Do not operate pan/tilt with- 1. Pan unit to the desired left or right position; adjust the appropriate limit stop ou
Краткое содержание страницы № 20
4.0 MAINTENANCE Clean the acrylic dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome. Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic plastic. Either liquid or spray cleaner/ wax suitable for fine furniture is acceptable. Interior Surface (Except Chrome) - Clean the same as the exterior surface. Interior Surface (Chrome) - The inside surface of a chrome dome is easil