Краткое содержание страницы № 1
®
ED25/ED2500/ED2620/ED27
Series Environmental Domes
Installation/Operation Manual
C437M-B (9/95)
PELCO • 3500 Pelco Way • Clovis, CA 93612-5699 • USA • www.pelco.com
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
Краткое содержание страницы № 2
TABLE OF CONTENTS Section Page 1.0 WARNINGS .......................................................................................................................................1 2.0 SCOPE ...............................................................................................................................................2 2.1 DESCRIPTION .........................................................................................................................2 3.0 INSTALLATION.........
Краткое содержание страницы № 3
INSTALLATION/OPERATION MANUAL CAUTION: ED25/ED2520/ED2620/ED27/ED2720 SERIES ENVIRONMENTAL DOMES This device is designed to operate at 24 volts AC power. Input voltage must not exceed 28 volts or drop below 22 volts or else DAMAGE TO THE MOTORS WILL OCCUR. Should you need technical assistance, please call (800) 289-9100. 1.0 WARNINGS Prior to installation and use of this product, the follow- ing WARNINGS should be observed. 1. Installation and servicing should only be done by Qualified Service
Краткое содержание страницы № 4
2.0 SCOPE The ED25/ED27 Series can be ordered as a dome only or with factory installed heater/blower and service light. The information contained in this manual covers the Other options include factory assembled integral pan/ ED25/ED2520/ED2620/ED27/ED2720 Series Environ- tilt and/or Coaxitron/Wiretron receiver/driver. mental Domes. The ED25 Series is designed for flush mount or pen- 2.1 DESCRIPTION dant mount applications. The ED25/ED2520/ED2620/ED27/ED2720 Series of The ED2620 Series is a pe
Краткое содержание страницы № 5
3.0 INSTALLATION 3.1.1 FMED25 Flush Mount Installation To mount the enclosure using the FMED25 flush mount, perform the following steps. Refer to Figure 2. CAUTION: Make certain that the mounting surface is capable of supporting the full load of 1. Secure the FMED25 flush mounting plate to a suit- the mount, pan/tilt, camera/lens and enclosure able surface and secure with suitable fasteners (not supplied) capable of supporting the weight of the dome, pan/tilt, camera and lens. Due to the wide
Краткое содержание страницы № 6
3.1.2 PMED25 Pendant Mount 3.2 PAN/TILT INSTALLATION/ Installation REMOVAL To mount the enclosure using the PMED25 pendant The following installation instructions are for remov- mount, perform the following steps. Refer to Figure 3. ing/installing the pan/tilt assembly. 1. Screw the PMED25 pendant mount to a suitable 1. The pan/tilt is secured to the back box by two (2) length of 1-1/2-inch MNPT threaded pipe which 1/4-20 nuts which hold the pan/tilt mounting has been securely fastened to a surf
Краткое содержание страницы № 7
3.3.2 Conductor Requirements The ED25/ED2520/ED27 Series environmental domes can be connected by a “hard-wire” system, Coaxitron or Wiretron system. The ED2620 Series dome is de- signed for hard-wire applications only. The distances for each of these system is as follows: Hard-wire Systems Coaxitron System Wiretron System Cable Size Max. Cable Distance Max. Cable Distance Max. Cable Distance 14 Awg 680 ft (207.3 m) — — 16 Awg 425 ft (129.54 m) — — 18 Awg 265 ft (80.77 m) — — 20 Awg 165 ft (50.2
Краткое содержание страницы № 8
Figure 5. ED2520/ED2720 Series Receiver/Driver Wiring Diagram 6 PELCO Manual C437M-B (9/95)
Краткое содержание страницы № 9
ED2620/ED2620-SL Pan/Tilt Wiring Diagram Qty Sym Description Part Number 1 C1 Capacitor, 15 MFD 100 V CAPU0015.0/100N 1 C2 Capacitor, 15 MFD 100V CAPU0015.0/100N 1 M1 Pan Motor PT350010010 1 M2 Tilt Motor 2508001 1 J2 Connector CONMAB6100 14 – Connector Pins CON66102-7 4 S1-S4 Switch SWI1SM1 1 – Input Connector CON206305-1 1 – Mating Connector SS1000ASSY 1 – Actuator SWIJS138B 1 – Lens Mating Connector CONMAS6100 BRN Common 1 S1 1 2 3 Left 3 RED M1 45 6 7 Right 7 BLU 8 910 11 C1 S2 12 13
Краткое содержание страницы № 10
Figure 7. Wiring Diagram for ED2520/ED2720 Dome Drives Figure 8. Wiring Diagram for ED2520-SL/ED2720-SL Dome Drives 8 PELCO Manual C437M-B (9/95)
Краткое содержание страницы № 11
Figure 9. Wiring Diagram for ED2520-PP/ED2720-PP Dome Drives Figure 10. Wiring Diagram ED2520SL-PP/ED2720SL-PP Dome Drives PELCO Manual C437M-B (9/95) 9
Краткое содержание страницы № 12
3.3.3 Video Synchronization, Alarm Follow the diagram in Figure 11, for appropriate video Terminal Diagram synchronization and alarm terminal wiring installation. The following wiring diagram illustrates the configu- ration of an additional four-position and six-position alarm terminal strip and additional video synchroniza- tion connection. These terminal strips are factory in- stalled as standard features on ED2520RX-PP, ED2520SL-RX/PP, ED2720RX-PP and ED2720SL- RX/PP models. Figure 11. Four-p
Краткое содержание страницы № 13
4.0 PAN/TILT LIMIT ADJUSTMENTS 5. Loosen the limit stop actuator (shown in Figure 12). Use the joystick to move the tilt table to the maximum tilt-up location and then move the limit CAUTION: DO NOT attempt to adjust limit stop actuator until it clicks the tilt-up limit switch. stops when the pan/tilt is in operation. Damage Then lock the limit stop actuator by tightening the to the equipment can result. Do not operate locking screw. equipment without limit stops. 6. Tilt up and down to verify
Краткое содержание страницы № 14
5.0 CARE AND MAINTENANCE 6.0 SERVICE AND REPAIR Regularly scheduled maintenance will prolong the op- 6.1 RECOMMENDED EQUIPMENT AND erational life and appearance of the equipment. TOOLS 1. Voltmeter or ohmmeter IMPORTANT: The lower dome of the ED25 2. Allen wrench set environmental dome is an optical surface. When 3. Wrench set cleaning the inner surface of the dome and view- 4. Screwdriver ing window, treat as carefully as you would a 5. Pliers, long nose fine camera lens. 6.2 SERVICE TIPS 1.
Краткое содержание страницы № 15
7.0 EXPLODED ASSEMBLY DIAGRAM Figure 14. ED25/ED26/ED27 Series Enclosure Exploded Assembly Diagram PELCO Manual C437M-B (9/95) 13
Краткое содержание страницы № 16
8.0 MECHANICAL PARTS LIST The following parts list corresponds to the exploded assembly diagram in Figure 14. Item Quantity Description Part Number 1 1 Enclosure front plate assembly ED25001003ASSY 2 1 Lower shock mount ED25004005COMP 3 2 Closing fasteners ED2510000 4, 8 8 Nylon washer SB310005 5 1 Dome ED254004COMP 6 4 Roller insert SB310007 7 4 Dome roller SB34020COMP 4 Roller “O” Ring (not shown) ED210100 9 1 Gas shock EH450010020 10 1 Back box assembly (ED25/ED26 only) ED25001000ASSY 1 Back
Краткое содержание страницы № 17
10.0 MODELS ED2620-PP Same as ED2620 except supplied with preset (PP) pan/tilt. (CE) ED25 14" diameter environmental dome fixed camera mount. Black opaque ED2620-SL Same as ED2620 except supplied with lower dome has smoked viewing win- SL option (360° pan setting). (CE) dow (1 f-stop light loss). (CE) ED27 14" diameter environmental dome with ED25-1 Same as ED25 except supplied with fixed camera mount and integral mount service light and heater/blower. arm. Black opaque lower dome with 1 f-stop
Краткое содержание страницы № 18
11.0 SPECIFICATIONS Enclosure MECHANICAL The following specifications apply to these models: Pan/Tilt ED25-1, ED2520, ED2520-SL, ED2520-PP, ED2520SL-PP, ED2620, ED2620-SL, ED27-1, Pan Rotation: 0-355° horizontal ED2720, ED2720-SL, ED2720SL-PP 0-360° horizontal (SL models only) Input Voltage: 120 VAC, 50/60 Hz Pan Speed: 24°/sec ±1 degree (no load condition) vA Required: 187 vA Tilt Rotation: -90° movement from horizontal plane Blower: 80 cfm at 13 watts Tilt Speed: 12°/sec ±.5 degree (no load (
Краткое содержание страницы № 19
GENERAL Pan/Tilt Enclosure Maximum Load: 10 lbs (4.6 kg) Max. Camera/Lens Construction: 0.025" aluminum frame Length: 12.50"L x 4.50"W x 3.25"H (31.75cm x 11.43cm x 8.25cm) (Product specifications subject to change without notice.) Construction: Back Box 0.080" aluminum 11.1 RECOMMENDED MOUNTS/ CONTROLS Viewing Window Optically clear acrylic which has been tinted, rated UL94HB. For information on recommended mounts and con- (Less than 1 f-stop light loss.) trols, please contact Pelco for a copy
Краткое содержание страницы № 20
12.0 WARRANTY AND RETURN INFORMATION WARRANTY RETURNS Pelco will repair or replace, without charge, any merchandise proved In order to expedite parts returned to the factory for repair or credit, please defective in material or workmanship for a period of one year after the date call the factory at (800) 289-9100 or (559) 292-1981 to obtain an of shipment. authorization number (CA number if returned for credit, and RA number Exceptions to this warranty are as noted below: if returned for repair)