Краткое содержание страницы № 1
Data Projector
MODEL
LVP-XD10U
LVP-SD10U
OPERATING GUIDE
Thank you very much for purchasing this DLP™ Technology Projector.
Please read this operating guide to ensure a correct use of the device. After reading
this manual, keep it for future reference.
Outline
This DLP™ Technology Projector can display
various computer signals and NTSC/PAL/
SECAM video signals.
Features
1. High brightness
2. High resolution
3. Compact size, light weight for portability
4. RGB input Terminal
5. Mouse Function
6.
Краткое содержание страницы № 2
COPYRIGHT Copyright © 2001 by this company. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language or computer language, in any form or by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior written permission of this company. DISCLAIMER This company makes no representations or warranties, either expressed or implied, with respect to the contents
Краткое содержание страницы № 3
SAFETY INSTRUCTIONS 1. Read all of these instructions before you operate your projector and save them for future reference. 2. The lamp becomes extremely hot during operation. Allow the projector to cool for approximately 45 minutes prior to removing the lamp assembly for replacement. Do not operate the lamps beyond the rated lamp life. Excessive operation of the lamps beyond the rated life could cause them to explode on rare occasions. 3. Power is still available when the projector is in the
Краткое содержание страницы № 4
Table of Contents Introduction .......................................................................................................................................... 1 Projector Features............................................................................................................................. 1 Description ........................................................................................................................................ 2 A FRONT (FIGURE) ..............
Краткое содержание страницы № 5
Introduction 1 Projector Features A Image Resolution Fully compatible with true SVGA (LVP-SD10U)/XGA (LVP-XD10U) and supports SXGA using advanced intelligent compression technology. The advanced intelligent compression technology enables it to present clear compression SVGA/XGA images without line omission. B Brightness Provides superior brightness using TI's Digital Micromirror Device (DMD) and our own optical design, with a geometric effect that increases light usage efficiency. By increasing
Краткое содержание страницы № 6
H AV box (Model name: VA-10U) An AV box is optional, and users can attach one or two to the projector. Additionally, our AV box video standard is compatible with: NTSC U.S. and Canada standard PAL Western Europe standard SECAM France and Eastern Europe standard NTSC4.43 Middle East standard If users want to watch CATV, an AV box will serve the need. Description A FRONT (figure) PROJECTION LENS Ventilation Hole Figure 1 Front view B REAR (figure) CONTROL PORT (FOR MOUSE) CONTROL PAD AC INLET AV
Краткое содержание страницы № 7
C BOTTOM (figure) ADJUSTABLE FEET LAMP COVER Figure 3 Bottom view Installation A Positioning This projector is basically designed to project on a flat projection surface. It can focus from 1.5m-12m and adjust the screen size like figure below. Figure 4 Positioning English 3
Краткое содержание страницы № 8
B Adjustable Feet Picture tilt and projection angle can be adjusted by twisting Adjustable Feet. Projection angle can be adjusted 2° to 8.5° degrees by rotating the front/center foot. The projector is also equipped with left adjustable foot. Figure 5 Adjustable feet (left/ right/ middle) Moving the Projector Use the carrying handle when moving the projector. Replace the lens cover and rotate the feet fully clockwise (to shorten the feet) when moving the projector to prevent damage to the projec
Краткое содержание страницы № 9
QUI START C CK ARD Accessories Please check and make sure your box contains everything listed below. If any pieces are missing, contact your dealer. PROJECTION LENS VENTILATION HOLE REMOTE CONTROL POWER CONNECTOR (2 PIN TO 3 PIN) AAA BATTERIES VGA CABLE (P/N.: 246D016-10) PS/2 MOUSE ADAPTER (P/N.: 246D016-20) SERIAL MOUSE ADAPTER (P/N.: 246D016-30) GENERAL CABLE (P/N.: 246D096-40) RCA CABLE (AUDIO/VIDEO) (ATTACHED TO VA-10U) (P/N.: 246D016-50) AUDIO CABLE (ATTACHED TO VA-10U) (P/N.: 246D016-60)
Краткое содержание страницы № 10
Connection 2 A Connecting the Projector to Computer/Notebook CONTROL PORT CONTROL PORT OUTPUT GENERAL CABLE COMPUTER IN (SUPPLIED) MOUSE ADAER PS/2 PORT FOR PS/2 PORT COMPUTER INPUT (SUPPLIED) INPUT VGA CABLE MPUTER (SUPPLIED) OUTPUT Figure 8 Connection to PC CONTROL PORT CONTROL PORT OUTPUT GENERAL CABLE SUPPLIED ( ) COMPUTER IN MOUSE ADAPTER PS/2 PORT COMPUTER FOR PS/2 PORT INPUT INPUT (SUPPLIED) VGA CABLE COMPUTER (SUPPLIED) OUTPUT Figure 9 Connection to notebook 6 English
Краткое содержание страницы № 11
Operation 3 Turn On/Off Procedure A Power on Press the Standby/On key for 2 seconds to turn on the lamp. The LED will blink orange during the warm up and will then light solid green. “INPUT SIGNAL DETECTED, ACTIVATING AUTO IMAGE” will be displayed on the screen after the projector has identified the input signal; “SEARCHING” message will be displayed on the screen if there is no signal input; “SYNC IS OUT OF RANGE” message will be displayed on the screen if the horizontal frequency of the
Краткое содержание страницы № 12
MAIN UNIT FUNCTION Auto To correct the size and phase of the projected image automatically. Keystone + To correct the upper distortion of the projected image when keystone occurs. Keystone - To correct the lower distortion of the projected image when keystone occurs. Menu To call the OSD menu. Standby/On To turn the projection lamp on and off. Standby/On Functions as an indicator showing the standby status. indicator Lamp status Lights or blinks when the lamp does not light. indicator Menu opera
Краткое содержание страницы № 13
MAIN UNIT FUNCTION Menu To correct the upper distortion of the projected image when keystone occurs. (Keystone +) To navigate through sub-pages or to increase the scale bar number. (Keystone -) To navigate through sub-pages or to decrease the scale bar number. Exit (Auto) To exit from the current page or OSD menu, and save setting changes. B Remote Control LED STANDBY/ON LASER MENU EXIT About laser beam FREEZE This remote control is class 2 (max. output 1 mW BLANK laser diode 640 - 660 nm)
Краткое содержание страницы № 14
Main Unit Function Standby/On Turns the projection lamp on and off. Freeze Pressing this button displays a still (frozen) picture. Magnify Pressing this button partially magnifies a displayed picture. (Move the picture with the Disk Pad after pressing the Magnify button.) Disk Pad When the OSD menu is active, Disk Pad acts as selecting device. When the on-screen menus are not active, it works as mouse pad. When the magnify function is active, use disk pad to move through the picture. Menu To
Краткое содержание страницы № 15
Figure 13 Battery replacement process Remote Control Range The range for operation is about 10 m (about 32 feet ) when the remote control points to the projector. The distance from the screen back to the projector must be less than 10 m (about 32 feet). Depending on the type of the screen, the distance will be different. Figure 14 Range Usage and Replacement of Lamp The light source lamp has a limited service life. The picture will become dark or the color will fade after the lamp has been used
Краткое содержание страницы № 16
2. "PLEASE CHANGE A NEW LAMP. THE POWER WILL TURN OFF AFTER 20 HOURS" will be displayed on the screen if the lamp has been operated for 980 hours. The "20" will count down (see figure 16). 3. "PLEASE CHANGE A NEW LAMP" will blink on the screen together with a green LED if the lamp has been operated for more than 1000 hours (see figure 17). The power will turn off automatically after 15 seconds. All three of the above messages will not display for more than 15 seconds, but each message will be
Краткое содержание страницы № 17
B Replacing the Lamp Replacing the lamp When replacing the lamp, turn off the projector and unplug the AC cord. Wait 45 minutes so that the lamp can cool. When this high-pressure lamp is hot, it may explode if it is improperly handled. Caution Dispose of used lamps in accordance with local authorities. As the lamp is made of glass, do not apply shocks to it or scratch it. Also, do not use an old lamp, as this could cause the lamp to explode. If it seems that the lamp has exploded (for exampl
Краткое содержание страницы № 18
4. Replace the lamp with a new one and fix it using the same screw. Firmly tighten the lamp screw. Loose screws could result in a poor connection, which could cause the unit to malfunction. 5. Install the lamp cover and fix it using a screw. To prevent burns, install the lamp cover and secure it using the screw. Do not turn on the power with the lamp cover removed. Whenever the lamp is replaced, reset the total operation time of the lamp. Do not reset if the lamp has not been replaced. Do n
Краткое содержание страницы № 19
Resetting Lamp Timer If replacing the lamp before reaching 1000 hours of operation, carry out the following procedure. OSD FUNCTION Press the Standby/On button for 2 seconds to turn on the lamp. Press the MENU button to display the OSD menu, Auto Press <- or -> to reset. and use the " " (KEYSTONE+) or " " (KEYSTONE- ) buton to select the Control page. Then press the Language En Fr De It Es Du Menu button again to high
Краткое содержание страницы № 20
Press the "Exit" (AUTO) button to leave the current sub-page, and press "Exit" (AUTO) the button again to leave the main OSD menu (at the same time the settings are saved). Input status PC input without AV box PC input with AV box Video input with AV box Sub-page Display Display Display Image Image Image Control Control Control Source Source A Display Page When a PC is the input source, there will be only four items on this page: Keystone, Brightness, Contrast, and Color Balance (Fig. 20). On th