Краткое содержание страницы № 1
Thank you for choosing a SunSplash® Series Overhead Projector. Dukane
SunSplash Overhead Projectors are available in rugged steel or durable ABS
plastic bases and a choice of 2000, 2200, 3000/2400 or 4000/3200 lumens.
Features of each model vary and can include a closed or open head; a single,
double or triple element lens; a wide angle lens and a lamp changer.
Because operation of all units is very similar, this manual covers all models
in the Dukane SunSplash Series.
Краткое содержание страницы № 2
IMPORTANT SAFETY INSTRUCTIONS When using your overhead projector, basic safety precautions should always be followed, including the following: 1. Read and understand all instructions before using. 2. Close supervision is necessary when any projector is used by or near children. Do not leave projector unattended while in use. 3. Care must be taken as burns can occur from touching hot parts. 4. Do not operate projector with a damaged cord or if the pro- jector has been dropped or damaged — until i
Краткое содержание страницы № 3
TABLE OF CONTENTS Page SPECIFICATIONS .................................................................. 1 ELECTRICAL SAFETY GROUNDING INSTRUCTIONS ........................ 1 INDEX OF FUNCTIONAL PARTS ................................................ 2 SETUP/ASSEMBLY................................................................. 3 OPERATION ......................................................................... 4 CLEANING .......................................................................
Краткое содержание страницы № 4
SPECIFICATIONS Following are features common to all SunSplash Series Overhead Projectors: Focusing ... Rack and Pinion Focusing for Precise Image Adjustment Dimensions .............. 13" (W) x 15" (D) x 36" (H) or 38" (H) Max. Mounting Holes ........................... For Roll Film Feed Attachment Aperture............................................................ 10.5" x 10.5" Head Elevation .............................................. Up to 30 Degrees Power ................................
Краткое содержание страницы № 5
PRIMARY LAMPRESERVE INDEX OF FUNCTIONAL PARTS A number of terms are used frequently in this instruction booklet. The OVERHEAD PROJECTOR will be easier to operate if you become familiar with the terms for the functional parts listed below: 1 2 7 8 3 4 9 5 6 1. OPEN HEAD 6. BASE 2. MAST 7. CLOSED HEAD 3. FOCUS KNOB 8. POWER SWITCH 4. STAGE 9. MAST MOUNT 5. STAGE OPENING LATCH TABS 2
Краткое содержание страницы № 6
SETUP/ASSEMBLY In order to protect the optical head during shipment, it and the mast have been packed apart from the base. 1. Remove the optical head/mast assembly and base from the shipping carton. 2. On plastic models, depress stage opening latch tabs on front of the stage and lift off stage (Step 1). Place stage aside. 3. Find the Allen head screw and the Allen wrench. (On plastic base models, find the Allen head screw, washer, wing nut and Allen wrench). 4. Take the mast and identify the low
Краткое содержание страницы № 7
OPERATION Place the projector on a firm level surface at a convenient operating height. Be sure vent areas of unit are not blocked. Plug the power cord into a 120V, 60 Hz AC outlet. Move power switch to ON position. Place a transparency on the stage and turn focus knob until image is in focus. Image elevation is adjusted by moving optical head up or down. Models equipped with a lamp changer system allow change of lamp by sliding a lever. TURN OFF POWER BEFORE CHANGING LAMP! Primary Lamp Reserve
Краткое содержание страницы № 8
SUNSPLASH SERIES OHP SELECTION CHART MODEL BRIGHTNESS LENS SYSTEM LAMP/LAMP CHANGER HOUSING SP2123 2200 lumens Open, single element with wide angle EYB, 360W, 75 Hrs. / No Durable ABS SP2223 2200 lumens Open, single element with wide angle EYB, 360W, 75 Hrs. / No Steel Constructed SP2125 2200 lumens Open, single element EYB, 360W, 75 Hrs. / No Durable ABS SP2225 2200 lumens Open, single element EYB, 360W, 75 Hrs. / No Steel Constructed SP2226 2200 lumens Open, single element EYB, 360W, 75 Hr
Краткое содержание страницы № 9
LAMP REPLACEMENT Lamp in projector: SP2xxx — 2000 lumen, uses a 360 watt EYB lamp, Dukane Part Number 456-186. SP4xxx — 4000 lumen, uses a 410 watt FXL lamp, Dukane Part Number 456-192. SP3xxx — 3000 lumen, uses a 360 watt ENX lamp, Dukane Part Number 458-188. WARNING Lamp and adjacent metal parts are hot. Allow lamp to cool before replacing. Glass components may shatter. Handle carefully. Lamp replacement, SP2xxx units: 1. Open unit stage by depressing the latch tabs on front of stage and lifti
Краткое содержание страницы № 10
FOR 2000 LUMEN MODELS — STEP 2 — Carefully pull out bulb. Lamp replacement, SP4xxx and SP3xxx units: 1. Open unit stage by depressing the latch tabs on front of stage and lifting (Step 1). Remove the stage. 2. Pull up retainer clip wires and rotate lamp cover into open position (Step 2). FOR 3000 & 4000 LUMEN MODELS — STEP 1 — Open stage. STEP 2 — Pull up retainer clip and rotate open the lamp cover. 8
Краткое содержание страницы № 11
FOR 3000 & 4000 LUMEN MODELS — 3. Squeeze the lamp retainer clip to free lamp. Carefully pull up the used lamp. Take caution since it may be hot. Allow time to cool (Step 3). 4. Place new lamp in socket. Push down until firmly seated. Avoid skin contact. Oil from skin can cause discoloration of the lamp capsule or re- flector. Hold lamp with a STEP 3 — cloth, tissue or gloved hand. Open lamp retainer clip and pull out the lamp. 5. Engage the lamp retainer clip. 6. Close lamp cover and replace co
Краткое содержание страницы № 12
SERVICING Shipping Information If it becomes necessary to return a unit, please use the original packing material or pack securely to insure safe shipment. Service Service and parts are available from Dukane or from an approved service station. Contact the Dukane Service Department at 1-800-676-2487 to order parts or for the nearest service station. Service manuals are also available at a nominal cost. No Charge Warranty Repairs Your unit must be taken or sent to Dukane or to an approved service
Краткое содержание страницы № 13
STORAGE 1. Controls should be in OFF position. 2. Store power cord in base compartment. 3. Protect unit from dust as much as possible. FRESNEL LENS REMOVAL Should it be necessary, the Fresnel lens can be removed by pressing fresnel release latches as shown below: Information on Lamp Warranty Projection lamps are warranted by the lamp manufacturer and not by the equipment manufacturer. If you have a lamp which you believe to be defective, contact the manufacturer of that particular lamp for the a
Краткое содержание страницы № 14
INTERNAL PARTS 4 3 2 2000 LUMEN MODELS 5 1 11 7 3000 & 4000 LUMEN MODELS 9 10 6 8 1. SAFETY INTERLOCK SWITCH 7. MIRROR 2. COOLING FAN 8. SAFETY INTERLOCK SWITCH 3. LAMP 9. MAST LOCK SCREW 4. REFLECTOR 10. RETAINER CLIP 5. MAST LOCK SCREW 11. LAMP HOUSING COVER 6. LAMP 12
Краткое содержание страницы № 15
5 YEAR LIMITED WARRANTY This Dukane projector is warranted to the original purchaser for a period of five (5) years from the original purchase date – in normal operating conditions – against defects in material and workmanship . DUKANE CORPORATION EXPRESSLY DISCLAIMS ALL OTHER WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. DURING THE WARRANTY PERIOD, DUKANE CORPORATION’S LIABILITY FOR ANY DEFECTIVE PRODUCT (except for the lamp, which is subject to whatever warranties