Owner’s Manual
®
SmartPro 2U Rackmount
Intelligent, Line-Interactive UPS Systems
120V Sine Wave Output • 2200VA—3000VA Capacities
SMART2200RM2U SMART3000RM2U
(Series Number: AGSM8207) (Series Number: AGSM8209)
SMART2200RMXL2U SMART3000RMXL2U
(Series Number: AGSM8208) (Series Number: AGSM7010)
SMART2200RMXL2UP SMART3000RM2UP
(Series Number: AGSM7012) (Series Number: AGSM7499)
SMART2600RM2U
(Series Number: AGSM7012)
Not suitable for mobile applications.
Important Safety Instructions 2
Mounting
Краткое содержание страницы № 2
Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during the installation, operation and storage of this product. Failure to heed these warnings may affect the warranty. UPS Location Warnings • Use caution when lifting the UPS. Because of the considerable weight of all rackmount UPS systems, at least two people should assist in lifting and installing them. • Install the UPS indoors, away from excess moisture or hea
Краткое содержание страницы № 3
Important Safety Instructions Battery Warnings • Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before performing battery replacement. Use tools with insulated handles. There are no user -serviceable parts inside the UPS. Battery replacement should be pe
Краткое содержание страницы № 4
Mounting (Rack) Mount your equipment in either a 2-post or 4-post rack or rack enclosure. The user must determine the fitness of hardware and procedures before mounting. If hardware and procedures are not suitable for your application, contact the manufacturer of your rack or rack enclosure. The procedures described in this manual are for common rack and rack enclosure types and may not be appropriate for all applications. Note: The illustrations may differ from yo
Краткое содержание страницы № 5
Mounting (Rack) continued 2-Post Mounting 2-post mounting requires a T ripp Lite 2-P ost Rackmount Installation Kit (model: 2POSTRMKITWM, sold separately). Mounting (Tower) Warning: When mounting the UPS system in a tower orientation, make sure the LCD Screen panel is at the top of the UPS, not at the bottom. Note: To mount the UPS in an upright (tower) position, 2-9USTAND is required (sold separately). Rotate the LCD Screen panel for easy viewing while the UPS is tower
Краткое содержание страницы № 6
Quick Installation 1 Plug the UPS into an outlet on a dedicated circuit. NOTE! after you plug the UPS into a live AC outlet, the UPS (in “Standby” mode) will automatically charge its batteries, but will not supply power to its outlets until it is turned ON. 1 2 Plug your equipment into the UPS.* * Y our UPS is designed to support only electronic equipment. You will overload the UPS if the total VA ratings for all the equipment you connect exceeds the UPS’s Output Capacity. To find yo
Краткое содержание страницы № 7
Optional Installation These connections are optional. Your UPS will function properly without these connections. 1 USB and RS-232 Serial Communications 1A Use the included USB cable (see ) or 1B DB9 serial cable (see ) to connect the communication port on your computer to the communication port of your UPS. Install on your computer the Tripp Lite PowerAlert 1A Software appropriate to your computer’s operating system. 1B 2 EPO Port Connection This optional feature is only f
Краткое содержание страницы № 8
Optional Installation continued 3 External Battery Connection (Select Models) A Y our UPS comes with a robust internal battery system; external batteries are needed only to extend runtime. Adding external batteries will increase recharge time as well as runtime. This UPS supports BP48V24-2U (limit 1) and BP48V60RT -3U 3 (unlimited). 3 A The illustration (see ) shows the location of your UPS’s External Battery Connector where you will insert the b
Краткое содержание страницы № 9
Basic Operation LCD Interface Note: This LCD image is shown with all icons illuminated. Under normal conditions, only select icons will be lit. 3-Digit Display: This display is generally used to show values for a given “Display” or “Control” screen. “ON/OFF” Button • To turn the UPS ON: After you plug the UPS into a live AC outlet, the UPS (in ”Standby” mode) will automatically charge its batteries, but will not supply power to its outlets until it is turned ON.
Краткое содержание страницы № 10
Basic Operation continued “ENTER/MUTE” Button To toggle settings options while viewing a control menu option, tap this button. The UPS power failure alarm can also be temporarily silenced by tapping this button. Once silenced, an alarm will automatically re-sound to indicate low battery conditions and can no longer be silenced. • Can be used in conjunction with the ON/OFF button to cancel the “OFF ” function. See “ON/OFF Button” instructions above.
Краткое содержание страницы № 11
Basic Operation continued INPUT Icon: Indicates that the 3-digit value displayed is the Input V oltage. OUTPUT Icon: Indicates that the 3-digit value displayed is the Output V oltage. LOAD Icon: Displayed in two modes: 1. Displayed in conjunction with the % icon and 3-digit value to indicate the load percentage. 2. Displayed in conjunction with K WH/Day and 3-digit value to indicate daily power consumption. 3. Both the L OAD icon and W arnin
Краткое содержание страницы № 12
Basic Operation continued Automatic Voltage Regulation Icon: Indicates that the AC input is either low or high and that the A VR function is actively boosting or cutting the line. The A VR icon is also used in conjunction with the EVENTS icon to indicate A VR events. EXTERNAL BATTERY Icon (Select Models): Displayed only when the EXTERNAL BA T TERY SET TING CONTROL is active. BATTERY CAPACITY Icon: Used to better describe the battery capac
Краткое содержание страницы № 13
Basic Operation continued Control Menu Options Enable/Disable Alarm Tap the button repeatedly to advance to the LCD display featuring the icon. Press the button to select ON or OFF alarm mode settings. The last option displayed before navigating away from this menu option will be the selected setting. Note: Disabling the alarm via this control menu option will silence the alarm under all conditions, including low battery conditions. LCD Brightness Tap the button
Краткое содержание страницы № 14
Basic Operation continued ON Battery Events This feature allows the user to view the number of times the UPS has experienced an ON Battery Event. To reset the counter to “0”, press and hold the button. Tap the button repeatedly to advance to the ON Battery Events display , as shown above. Note: The value displayed is a random value used for example reference. AVR Events This feature allows the user to view the number of times the UPS has experienced
Краткое содержание страницы № 15
Basic Operation continued Tap the button repeatedly to advance to Sensitivity display, as shown on the previous page. Press the button to advance through the options. The last option displayed, before navigating away from this menu option, will be the selected setting. External Battery Setting Control (Select Models) This control menu option only appears when the UPS is configured using the External Battery Utility software and is reporting “YES” in the External Batter
Краткое содержание страницы № 16
Basic Operation continued Other UPS Features (Rear Panel) AC Outlets: All models include NEMA 5-15R and/or NEMA 5-20R outlets. Select models also include NEMA L5-30R and/or NEMA L5-20R outlets. These outlets provide your connected equipment with AC line power during normal operation and battery power during blackouts and brownouts. The UPS protects equipment connected to these outlets against damaging surges and line noise. If you have a serial or
Краткое содержание страницы № 17
Basic Operation continued Output Breaker (select models): Y our UPS features one or more breakers that protect your UPS from output overload. If one or more breakers trip, remove some of the load on the circuit(s), then reset them by pressing the breaker switch(es) in. Ground Screw: Use this to connect any equipment that requires a chassis ground. Storage and Service Storage Before storing your UPS, turn it completely OFF : with the UPS ON and receivi
Краткое содержание страницы № 18
Battery Replacement Under normal conditions, the original batteries in your UPS will last many years. See Safety section before replacing batteries. The batteries are designed for hot-swap replacement (i.e. leaving the UPS in ON mode), but some qualified service personnel may wish to put the UPS in the OFF mode and disconnect equipment before proceeding. Note: Refer to the label on the battery retention plate for the R.B.C. part
Краткое содержание страницы № 19
Battery Replacement 5 Add New Batteries 7 R eplace Battery Retention Plate 5A First, install the right row of batteries by inserting them and sliding them to the 5B right. Then, install the left row of batteries. 4 x screws 7 8 Replace Front Panel 5A 4 x screws 8 5B 6 Connect Batteries Attach both sets of connectors as shown: black-to-black and red-to-red. Always ensure that the battery terminals are properly secured. 6 19 12-12-037-93-3088-B.indb 19 12/26/2012 3:47:40 PM
Краткое содержание страницы № 20
Battery Replacement SMART3000RM2U, SMART2600RM2U, SMART2200RMXL2UP, SMART2200RMXL2U and SMART2200RM2U Battery (RBC94-2U) Replacement Procedure 1 Remove Front Panel 5 Add New Batteries Install the replacement batteries by sliding them directly into the UPS cabinet. 4 x screws 1 2 Remove Battery Retention Plate 5 6 Connect Batteries Attach both sets of connectors as shown: black-to-black and red-to-red. Always ensure that the battery terminals are properly secured. 4 x scre